ABB 1SDA067394R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA067394R1
Manufacturer
ABB
Part number
1SDA067394R1

Quick Summary

ABB 1SDA067394R1 is a three-pole Moulded Case Circuit Breaker used for reliable motor and power distribution protection in industrial switchgear. Engineers often battle nuisance trips and inconsistent protection coordination, especially in evolving panel layouts. This XT1-based device carries CE conformity with EC Declaration of Conformity, plus GL and LR certificates, supporting safe, auditable deployments. Built to integrate with the SACE Tmax XT family, it delivers predictable protection, straightforward front-terminal wiring, and scalable performance for growing electrical infrastructure needs.

Product Information

Extended Description

1SDA067394R1 ABB: C.BREAKER TMAX XT1C 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 50-500 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
6963f79e-5b3e-491f-8111-ed51582b95f5 Italy (IT)
Simplified SCIP
03623cf1-c0d9-4f9d-a987-0129b1b5c4e3 Germany (DE) | 0b897293-8966-400d-85d3-3adb67e5645e Netherlands (NL) | 788f7ce1-ce81-46b1-b516-e8a1a5810a29 Netherlands (NL) | aa1def39-a5e1-402c-a7fb-1f69c65bf0cf Germany (DE) | 75a37be3-c5f2-48d2-921c-196f3e715fbb Denmark (DK) | 2b729765-22b2-414d-96db-c45c85b86b34 Germany (DE) | 73e3b539-3241-4e7c-b2e3-a271a8580cce Croatia (HR) | f266fe7c-cd54-450c-984b-762ab9f9b7b5 Czech Republic (CZ) | 01bac839-3a95-4abc-9842-01bf939126de Netherlands (NL) | 6d189084-7c30-4847-b66c-12452df5457e Netherlands (NL) | afbc9104-3742-44d7-8a17-ef24c66adf7e Estonia (EE) | fa14a73d-5be7-45d6-bea7-eef52df9a461 Greece (GR) | c090809c-f591-4fd0-8f91-3f7005422d41 Portugal (PT) | 8c6a9e39-4f7d-4d91-a84a-7c5fae9fab39 Bulgaria (BG) | a751af1f-ba16-4b16-bae1-88bd49a124fd Sweden (SE) | 189d8f20-fd0b-4ae9-9160-02cedac39911 Poland (PL) | dfa00889-9143-4640-beda-7b68e77263b4 France (FR) | e2a75877-0b3c-423d-a60d-9205fd4b7277 Sweden (SE) | 2ba6904a-b275-40a0-a662-5277d2f0e712 Germany (DE) | dbbe5839-4af6-41b6-a0d9-d91eb8454cb5 Germany (DE) | b8b8214a-1d31-430b-aa6b-829d2c2e0845 Spain (ES) | 30e0bf90-1472-4e80-9b14-b35167a34379 Netherlands (NL) | 3fc61ee0-7133-460e-943f-e79dba217b6d Poland (PL) | 5e5400ef-76f0-49e1-9aff-19542ffb47e1 Poland (PL) | 1bc8a6dc-76f2-4cd5-8b92-6cd0b382a8e5 Finland (FI) | 46710f5a-a1b8-4e6f-92eb-28c07b84c61b Norway (NO) | ecb4dd9f-7134-4b06-9ce6-ba53c0aceabe France (FR)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1CE3050AFF000XXX
E-Number (Finland)
3638609
E-Number (Norway)
4309614
EAN
8015644695194
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.12 kg
Package Level 1 EAN
8015644695194
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.7 W
Rated Current (In)
50 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 12.5 kA | (500 V AC) 9 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
C
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The XT1 three-pole design delivers robust protection with front terminals, enabling quick panel assembly and simplified maintenance. Business impact: faster installation times and reduced field wiring errors, improving project timelines in new builds and retrofits. Application: power distribution panels and switchgear in manufacturing facilities benefit from the 50 A nominal rating and 690 V operation, supporting reliable protection without over-dimensioning. The TM release with a 35–50 A setting range allows precise coordination with downstream devices, minimizing unwanted trips while preserving safety. Application: transformer protection and downstream feeder protection across industrial plants. The high short-circuit breaking capacity (Ics up to 40 kA) ensures resilience against high-energy faults, reducing equipment damage and downtime. Practical benefit: enhanced safety margins during transformer or generator-fed load changes. The unit’s electrical durability (up to 8000 cycles) and mechanical durability (up to 25000 cycles) translate to longer service life in demanding environments, lowering lifecycle costs. Application: continuous-duty panels and high-cycle motor control centers. Compatibility with main distribution standards (IEC 60947-2) and standard front-terminal connections streamline retrofits and spare-part sourcing, reducing downtime during maintenance windows. The front-terminal, bolt-type connection and 6 N·m tightening torque support reliable, vibration-resistant wiring in industrial settings. The product’s ECOsolu tions alignment and recyclable packaging contribute to waste reduction goals, appealing to modern procurement policies. Overall, the ABB Tmax XT1 family ensures consistent performance, better protection coordination, and tangible cost savings across the life of the installation.

Get a Quick Quote for a ABB 1SDA067394R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067394R1? Enquire Now

FAQs

To install the ABB 1SDA067394R1 XT1 three-pole MCCB, mount it with the front terminals as designed and secure the device in the panel frame. Connect the main busbar within the 45.5 to 80 mm² range and tighten each bolt to 6 N·m. Ensure a solid mechanical fit and proper conductor seating for reliable operation under 690 V systems.
Set the device within the 35 to 50 A range to tailor overload protection to downstream circuits while maintaining selective coordination. The Tmax XT1 offers a 50 A rated current with Ics up to 40 kA short-circuit capability, so precise settings reduce nuisance trips and limit fault energy without compromising safety.
Yes, the XT1 model is part of the SACE Tmax XT family, sharing mounting, front-terminal configuration, and standard electrical characteristics. Its fixed 3P front-terminals simplify wiring, minimize panel depth, and support quick retrofits in existing switchboards while maintaining IEC 60947-2 compliance.
Core certifications include CE with EC Declaration of Conformity, GL and LR product certificates, plus ETIM and SCIP data. These approvals validate compliance with IEC 60947-2, RoHS, REACH, and waste management requirements, aiding supplier qualification, audits, and adherence to environmental and safety standards.
Electrical durability is rated up to 8000 cycles and mechanical durability up to 25,000 cycles under standard conditions. Plan preventive maintenance by inspecting terminal connections, verifying torque at 6 N·m, and performing periodic functional checks of the thermal-magnetic release to ensure reliable tripping in demanding industrial environments.