ABB 1SDA067395R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067395R1
Quick Summary
ABB 1SDA067395R1 Moulded Case Circuit Breaker is a 3-pole XT1 device designed for reliable overcurrent protection in low-voltage distribution. The challenge engineers face is delivering compact, front-access protection with precise trip settings in tight panels. This model meets IEC 60947-2 compliance and carries CE conformity, LR and GL certificates for global installations, while supporting ABB EcoSolutions for sustainable design. With a rated current of 63 A and front-terminal accessibility, it offers a practical balance of protection, installability, and long-term operational value for power distribution projects.
Product Information
Extended Description
1SDA067395R1 ABB: C.BREAKER TMAX XT1C 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 63-630 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
f8a3db18-b215-4bf0-a188-36b92353ada8 Italy (IT)
Simplified SCIP
4e7a6161-4fb1-4b8a-8a4b-542662f9e352 Germany (DE) | 61163b89-f1d3-4644-940f-389133811615 Norway (NO) | 2f6d6e62-1dcc-47cf-ad5c-29c527733f13 France (FR) | 8f5b62da-4d76-4087-8af5-5e267aa1bcbd Netherlands (NL) | a5b18f3c-1c9e-449f-b68a-6bd7c7c24284 Estonia (EE) | b5e666e4-dbce-4a12-99f4-267847012e0c Greece (GR) | 159b8e0c-28d9-4a88-aa7e-aee17a1f5e01 Portugal (PT) | 49caf4a0-669f-44aa-8705-1686cc584012 Bulgaria (BG) | 1dee6090-aae8-48be-9df2-02b6bafff9eb Sweden (SE) | f5ac57bd-6df7-45cd-8a34-b9742ee54117 Poland (PL) | 04919024-e6ac-4bbc-8560-440eb1c781e5 Netherlands (NL) | 4ed2cdb0-2e6d-42d6-8906-e2c821f942f9 Germany (DE) | 8ae58a5c-dcda-4cc8-a917-fbc2e4708463 Denmark (DK) | e2db9e39-108b-408e-8012-427eb24260d6 Germany (DE) | 7f31893f-1c43-4c83-ac6e-7eaf2f302bc0 Croatia (HR) | b25a6819-161b-437b-86d0-3a810a0bf6eb Czech Republic (CZ) | 6f0de107-6c8e-40e8-9ae7-2e6b31050fbe Netherlands (NL) | 8a56db9b-06ae-49ad-86d5-90505b400768 France (FR) | ccb3f727-1d52-4e59-b8bc-31ce6d2020ae Sweden (SE) | ac17958f-7474-4c63-8477-7c0aa63eaf38 Germany (DE) | 86c9d61c-adcf-4e9d-bf83-3823fb1f79d4 Germany (DE) | 6a7802f3-2cc5-4734-a714-cda6e80b692e Netherlands (NL) | 73a11258-c80d-4439-ac10-7ff065d2f0d1 Spain (ES) | 31622732-cbc3-4f89-aa69-1a71dd936b0a Netherlands (NL) | cd86e4f0-784b-4f10-80b3-3648eb7dcd8a Poland (PL) | aa099d69-662c-40b5-9eca-e20ca28f62b2 Poland (PL) | 127662e9-0342-459b-9ee2-630c6b565474 Finland (FI)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1CE3063AFF000XXX
E-Number (Finland)
3638776
E-Number (Norway)
4309615
EAN
8015644012199
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.135 kg
Package Level 1 EAN
8015644012199
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In)
63 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
630 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 12.5 kA | (500 V AC) 9 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
44.1...63 A
Short-Circuit Performance Level
C
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The XT1 3P fixed front-terminal design reduces installation time by enabling straightforward wiring and quicker maintenance checks in panel boards, improving overall project schedules for electrical installations. This directly translates to lower labor costs and faster commissioning in manufacturing plants and data centers. Feature → Business Impact → Application: Rated current of 63 A and a rated operational voltage of 690 V equip this breaker for scalable power distribution, supporting modular panel assemblies and transformer protection schemes in industrial facilities. Application includes switchgear in machine rooms and MCCs where reliable fault clearance is critical. Feature → Business Impact → Application: Setting range from 44.1 to 63 A provides precise coordination with downstream protection, optimizing selectivity and minimizing nuisance trips in complex electrical networks. This supports energy efficiency initiatives and reduces unplanned downtime in process industries. Feature → Business Impact → Application: Front-terminal and bolt terminal connection type with a tightening torque of 6 N·m ensures robust, vibration-resistant connections in harsh environments, improving reliability in rolling stock, conveyors, and heavy machinery. Feature → Business Impact → Application: Compliance with IEC 60947-2, CE, LR and GL certificates affords confidence for global deployments, easing procurement for multinational projects and simplifying regulatory alignment in plant expansions. Feature → Business Impact → Application: Product integration with ABB EcoSolutions and documented disassembly instructions support sustainable end-of-life planning, helping facilities meet waste diversion targets and lifecycle cost goals while maintaining safety and compliance.
Get a Quick Quote for a ABB 1SDA067395R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067395R1?
Enquire Now
FAQs
This 3P XT1 fixed front-terminal molded case circuit breaker is designed for low-voltage distribution panels, MCCs, and transformer protection schemes. It supports front-edge wiring with a 6 N·m tightening torque and a 76.2 mm width, facilitating compact, service-friendly installations in control cabinets and machine rooms.
Key specifications include a rated current of 63 A, rated voltage of 690 V, and Icu/Ics of 40 kA. It employs a 3P configuration with a setting range of 44.1–63 A, a 30 ms opening time under SOR/UVR, and a power loss of 4.3 W per pole under rated conditions.
Yes. It carries IEC 60947-2 conformity, a CE declaration of conformity, and LR and GL certificates, ensuring suitability for multinational projects and consistent regulatory compliance across regions.
Front-terminal access simplifies wiring and replacement, while the Front/Bolt terminal design paired with a 6 N·m torque ensures durable connections even in vibration-prone environments. The 3P XT1 format also supports straightforward replacement in existing Tmax XT installations, reducing field retrofit time.
Ideal for low-voltage power distribution in manufacturing plants, transformers, and control panels. It is well-suited for equipment requiring reliable short-circuit protection, precise coordination, and compliance with international standards for global projects.