ABB 1SDA067402R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA067402R1
Manufacturer
ABB
Part number
1SDA067402R1

Quick Summary

ABB SACE Tmax XT molded case circuit breaker 4P protects industrial power distribution and motor circuits. Panel builders often struggle with space, wiring complexity, and keeping up with evolving regulatory data. This XT1 model carries CE conformity with a DoC, IEC 60947-2 compliance, and RoHS/CMRT environmental declarations, helping you meet regulatory requirements and lifecycle responsibilities. For OEMs and integrators, the compact 4P front-terminal design, plus adjustable 28–40 A settings, enables consistent protection across panels while reducing installation time and service costs.

Product Information

Extended Description

1SDA067402R1 ABB: C.BREAKER TMAX XT1C 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 40-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1CE4040AFF000XXX
E-Number (Finland)
3640517
E-Number (Norway)
4309713
EAN
8015644012960
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.431 kg
Package Level 1 EAN
8015644012960
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.6 W
Rated Current (In)
40 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 12.5 kA | (500 V AC) 9 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
28...40 A
Short-Circuit Performance Level
C
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → 4P XT1 front-terminal design provides a compact footprint and clean wiring, reducing panel size and installation time. Business Impact → Lower enclosure costs and faster panel assembly. Application → Main distribution boards and motor control centers. The 4-pole structure supports synchronized protection across phases, improving system reliability for 690 V networks. Feature → Adjustable setting range 28–40 A enables precise overcurrent protection, minimizing nuisance trips without compromising safety. Business Impact → Optimized protection for diverse loads, reducing downtime and extending equipment life. Application → Feeders to pumps, conveyors, and critical machinery. Feature → High short-circuit performance with Ics up to 40 kA and Icu up to 40 kA across voltages. Business Impact → Strong fault containment, protecting transformers and motors from damage. Application → South- and medium-voltage distribution panels. Feature → Front-terminal bolt connections with 6 N·m tightening torque simplify installation and maintenance. Business Impact → Safer handling and reliable, repeatable terminations in dense panel layouts. Application → Panel assembly and service work, especially in retrofit projects. Feature → Compliance and sustainability data including IEC 60947-2, RoHS, CMRT, and EPD. Business Impact → Streamlined engineering approvals and reduced total cost of ownership over the product lifecycle. Application → Corporate sustainability reporting and procurement specs. Feature → Robust mechanical durability (up to 25,000 cycles) and electrical durability (up to 8,000 cycles per hour). Business Impact → Longer service intervals, lower replacement risk in high-usage environments. Application → Continuous operation in manufacturing lines and process controls.

Get a Quick Quote for a ABB 1SDA067402R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067402R1? Enquire Now

FAQs

The XT1 4P is designed for high-voltage low-voltage distribution up to 690 V with front-terminal bolt connections. It supports a 28–40 A setting range, tightening torque of 6 N·m, and busbar connection suitable for 45.5–80 mm² cross-sections, enabling neat, code-compliant panel assemblies with rapid field servicing.
Key specs include rated current IN = 40 A, rated voltage Ur = 690 V, Ui = 800 V, Ics up to 40 kA, and Icu up to 40 kA. The setting range is 28–40 A, with 4P configuration and front-terminal connections. This ensures coordinated protection for feeders and motors while meeting IEC 60947-2 requirements.
Yes. The XT1 features a TM release (TMD) with a 30 ms opening time and a 4P configuration ideal for motor feeders. Its adjustable setting range and high breaking capacities help protect motors from short circuits while minimizing nuisance trips in dynamic load conditions.
The product complies with IEC 60947-2 and CE requirements, and it carries RoHS and CMRT declarations. It also provides EPDs for Tmax XT XT1 and support for disassembly instructions, aiding sustainability reporting and end-of-life planning.
With a mechanical durability rating up to 25,000 cycles and electrical durability up to 8,000 cycles per hour, the XT1 minimizes maintenance downtime. Front-terminal access and a compact 4P footprint reduce service time, while robust protection capabilities lower replacement costs in high-demand environments.