ABB 1SDA067408R1 Moulded Case Circuit Breaker - XT1 CE

Part Number: 1SDA067408R1
Manufacturer
ABB
Part number
1SDA067408R1

Quick Summary

ABB 1SDA067408R1 Moulded Case Circuit Breaker is designed for reliable protection in power distribution and machinery control. This 4-pole XT1 device delivers precise overcurrent protection with a front-terminal design for easy wiring in control panels. A common pain point in panel design is achieving fast fault isolation without compromising space or serviceability; XT1 helps by offering compact dimensions and a robust release mechanism. Certifications such as CE conformity, GL, and LR approvals demonstrate compliance across European markets and critical industries. With a 160 A rating, 690 V operating voltage, and 800 V insulation, this breaker supports modern energy systems while reducing maintenance costs. It also integrates smoothly with existing Tmax XT ecosystems, helping you standardize protection across sites.

Product Information

Extended Description

1SDA067408R1 ABB: C.BREAKER TMAX XT1C 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 160-1600 A NEUTRAL = 50% PHASES
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
a3d05883-9ebe-40a7-9dc7-463ca2c390fb Italy (IT)
Simplified SCIP
8c8d64fd-d56d-4d06-ab34-0c9d4cebe336 Germany (DE) | e8359589-dd74-4097-9513-d28183829fa2 Netherlands (NL) | 998b4f9c-253e-4ce3-9ebe-96418c29dc93 Spain (ES) | 8a08b254-8ea8-4913-9af9-4e988d46cc02 Netherlands (NL) | c81e7525-4d92-4ab5-8020-61debb4473f2 Greece (GR) | bf68dc18-423c-4d3d-988a-303877164859 Poland (PL) | 13fd83d3-a734-4480-80e9-f1a6e13bf39c Norway (NO) | 208bf1f1-6ce5-451e-ae76-33a3d72066ce Finland (FI) | 3721a7ec-6832-4072-b085-0da076caf4b5 Netherlands (NL) | 8d81aff3-24b6-43a2-98e5-168b2efde39b Germany (DE) | 6df0342c-f01a-4393-a0fb-ef67c10b9102 Denmark (DK) | 3f4438fb-9939-4571-9bd8-b086c4ba014b Germany (DE) | e64950da-3fb4-41fd-b76a-04225b942f93 Croatia (HR) | ed1a8410-0107-4432-8b54-061a8d381e6a Czech Republic (CZ) | 79bd0e81-61fb-49b8-b2e6-ab5c8376b80d Poland (PL) | a181be70-1ffd-48c1-8cd3-497a5c9d032b Netherlands (NL) | 158d8721-efd1-4f62-bb72-ccb7575c08ad Netherlands (NL) | 21bb78f5-2000-4aa9-8d4c-a6075cdcd1fa Estonia (EE) | 7240969c-88cf-4ad8-91a4-12a0fd5dc5d9 Portugal (PT) | 4ffa45cc-0d1a-4ce5-a785-0a979dde881e Germany (DE) | 6a40eacb-17ed-4a24-9242-bbc295d338a5 Germany (DE) | 50023ce6-3d95-4ad4-9288-115227be92ab France (FR) | 7240969c-88cf-4ad8-91a4-12a0fd5dc5d9 Portugal (PT) | d9d3e96f-8dad-4404-b9af-58436248d520 Bulgaria (BG) | ee9762c8-f4f0-40eb-a156-fb912bb4f712 Sweden (SE) | 976df1a7-e48c-412b-88db-bb7ca712e0fd Poland (PL) | 98de693a-104a-4b91-b746-74166febd900 France (FR) | cf8851b4-b83c-479b-9b69-418200fa7b67 Sweden (SE) | 13fd83d3-a734-4480-80e9-f1a6e13bf39c Norway (NO) | 208bf1f1-6ce5-451e-ae76-33a3d72066ce Finland (FI) | 3721a7ec-6832-4072-b085-0da076caf4b5 Netherlands (NL) | 8d81aff3-24b6-43a2-98e5-168b2efde39b Germany (DE) | 6df0342c-f01a-4393-a0fb-ef67c10b9102 Denmark (DK) | 3f4438fb-9939-4571-9bd8-b086c4ba014b Germany (DE) | e64950da-3fb4-41fd-b76a-04225b942f93 Croatia (HR) | ed1a8410-0107-4432-8b54-061a8d381e6a Czech Republic (CZ) | 79bd0e81-61fb-49b8-b2e6-ab5c8376b80d Poland (PL) | a181be70-1ffd-48c1-8cd3-497a5c9d032b Netherlands (NL) | 158d8721-efd1-4f62-bb72-ccb7575c08ad Netherlands (NL) | 21bb78f5-2000-4aa9-8d4c-a6075cdcd1fa Estonia (EE) | c81e7525-4d92-4ab5-8020-61debb4473f2 Greece (GR) | d9d3e96f-8dad-4404-b9af-58436248d520 Bulgaria (BG) | ee9762c8-f4f0-40eb-a156-fb912bb4f712 Sweden (SE) | 8a08b254-8ea8-4913-9af9-4e988d46cc02 Netherlands (NL) | 976df1a7-e48c-412b-88db-bb7ca712e0fd Poland (PL) | 98de693a-104a-4b91-b746-74166febd900 France (FR) | cf8851b4-b83c-479b-9b69-418200fa7b67 Sweden (SE) | 4ffa45cc-0d1a-4ce5-a785-0a979dde881e Germany (DE) | 6a40eacb-17ed-4a24-9242-bbc295d338a5 Germany (DE) | 50023ce6-3d95-4ad4-9288-115227be92ab France (FR) | e8359589-dd74-4097-9513-d28183829fa2 Netherlands (NL) | 998b4f9c-253e-4ce3-9ebe-96418c29dc93 Spain (ES) | bf68dc18-423c-4d3d-988a-303877164859 Poland (PL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1CEN160AFF000XXX
E-Number (Finland)
3640512
EAN
8015644013028
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.442 kg
Package Level 1 EAN
8015644013028
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 15 W
Rated Current (In)
160 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1600 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 12.5 kA | (500 V AC) 9 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 40 kA | (230 V AC) 40 kA | (240 V AC) 40 kA | (380 V AC) 25 kA | (415 V AC) 25 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 8 kA | (690 V AC) 4 kA | (250 V DC) 2 Poles in Series 25 kA | (500 V DC) 3 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
112...160 A
Short-Circuit Performance Level
C
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Front-terminal fixed design enables rapid, safe wiring with minimal panel intrusion → Result: reduces wiring errors and shortens commissioning time in control panels and distribution boards. Application: ideal for space-constrained installations in machine rooms and cabinet enclosures. Feature → Thermomagnetic release (TMD) provides fast, selective tripping while resisting nuisance trips → Result: improves uptime and safety for motors and transformers in production lines. Application: motor feeders and transformer protections in energy-intensive environments. Feature → Rated current 160 A, rated insulation voltage Ui 800 V, rated operational voltage Ur 690 V → Result: supports high-energy, multi-voltage systems with reliable protection margins. Application: medium-voltage distribution feeders and transformer protection schemes. Feature → Short-circuit performance Ics/Icu up to 40 kA depending on voltage → Result: robust protection against severe faults, reducing damage and downtime. Application: critical power feeds in data centers and manufacturing cells. Feature → Compatibility with Tmax XT ecosystem and front-terminal assembly simplifies upgrades from older devices → Result: lowers total cost of ownership through standardized parts and easier maintenance. Application: phased retrofits across multi-site plants. Feature → Environmental compliance and recyclability information (EPD, EN45555) supports sustainability goals and regulatory reporting → Result: aligns procurement with green programs and supplier ESG targets. Application: panel design in industries with strict waste and resource loop requirements.

Get a Quick Quote for a ABB 1SDA067408R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067408R1? Enquire Now

FAQs

The 1SDA067408R1 uses fixed front terminals and a 4P configuration, compatible with 45.5–80 mm2 busbar cross-sections and standard panel cutouts. Follow the 6 N·m tightening torque guideline to ensure secure connections and optimal heat dissipation in restricted-space enclosures.
This Tmax XT1 device offers Iu of 160 A and Ui of 800 V, with short-circuit ratings up to 40 kA depending on the applied voltage. Ics and Icu values are specified for common voltage ranges (for example around 40 kA at 230–240 V), delivering robust protection for feeders and transformers.
Yes. With a rated operational voltage of 690 V and high short-circuit breaking capacity, the XT1 4P is well-suited for transformer protection, distribution feeders, and upstream switching in industrial plants. Its TMD release provides selective, fast tripping to minimize collateral outages.
The product carries a CE Declaration of Conformity for Tmax XT1, along with GL and LR certificates. Additional documentation includes EPDs and SCIP declarations, supporting sustainability and regulatory compliance across European markets.
The XT1’s solid mechanical durability and reliable thermomagnetic release reduce maintenance frequency and unplanned downtime. Front-terminal accessibility simplifies inspection, and standardized Tmax XT spare parts improve replacement logistics, contributing to lower lifecycle costs and better uptime.