ABB 1SDA067414R1 Tmax XT Moulded Case Breaker - IEC 60947-2

Part Number: 1SDA067414R1
Manufacturer
ABB
Part number
1SDA067414R1

Quick Summary

ABB Tmax XT 1SDA067414R1 is a 3P molded case circuit breaker for transformer and motor protection in industrial systems. Engineers often face space constraints and the need for reliable interruption during faults. This unit offers CE conformity, GL and LR certifications, RoHS and REACH compliance to meet regulatory and environmental requirements. As part of the SACE Tmax XT family, it delivers a compact footprint with front-terminal installation and robust protection coordination, enabling faster panel builds and lower lifecycle costs for distributors and end users alike.

Product Information

Extended Description

1SDA067414R1 ABB: C.BREAKER TMAX XT1N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 63-630 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
27b3f7d2-9a9d-4702-8c8b-78b0b8988401 Italy (IT)
Simplified SCIP
aee58fd4-1e56-4298-8189-3e5115abb462 Germany (DE) | 1ffadfff-ebc9-4810-a077-a29ee05933b3 Poland (PL) | 0417799a-9290-4abf-abf6-7774a98a30b1 Bulgaria (BG) | 2eca5665-1d25-4516-8b70-b764a7bdf9a5 Sweden (SE) | 67bee0e5-9901-4ef0-9128-7849a7b0e517 Poland (PL) | 37737179-f4ca-49f4-9dc8-1b69cef21c3e France (FR) | 4ba80cd9-4f6f-47f4-b1a0-8d5221b573c8 Germany (DE) | cdbb3483-9890-4a46-bbaa-6066e66326c8 Denmark (DK) | f34ae812-e6f3-45e4-bf17-926328d6ea32 Germany (DE) | ffa365ad-0a63-4996-801f-9f907780595d Croatia (HR) | ee4808c3-7716-4e4a-aed8-cb20d3a302e0 Czech Republic (CZ) | c6e727f6-36d0-4492-8eba-cf90e63de90c Poland (PL) | a7059471-1c97-4e1b-8c16-d767eaa1c627 Netherlands (NL) | 1ffadfff-ebc9-4810-a077-a29ee05933b3 Poland (PL) | 7b27d125-3eb3-47c4-841f-238495ac7db9 Norway (NO) | 28b49d81-2c93-478b-97cd-b12793dd7015 Finland (FI) | 1c033f72-17ba-46e7-b6b0-b4d95e52f2d7 Netherlands (NL) | 7b27d125-3eb3-47c4-841f-238495ac7db9 Norway (NO) | 28b49d81-2c93-478b-97cd-b12793dd7015 Finland (FI) | 1c033f72-17ba-46e7-b6b0-b4d95e52f2d7 Netherlands (NL) | 4ba80cd9-4f6f-47f4-b1a0-8d5221b573c8 Germany (DE) | cdbb3483-9890-4a46-bbaa-6066e66326c8 Denmark (DK) | f34ae812-e6f3-45e4-bf17-926328d6ea32 Germany (DE) | ffa365ad-0a63-4996-801f-9f907780595d Croatia (HR) | ee4808c3-7716-4e4a-aed8-cb20d3a302e0 Czech Republic (CZ) | c6e727f6-36d0-4492-8eba-cf90e63de90c Poland (PL) | a7059471-1c97-4e1b-8c16-d767eaa1c627 Netherlands (NL) | 5160fe50-30eb-4851-a4ad-c7489bce1f81 Netherlands (NL) | 4c33881f-f0a2-4ab4-8b05-80f0dc6957d1 Estonia (EE) | 7a8aa60f-fb7b-4633-9554-857968df1c0b Greece (GR) | b9e146ff-487a-40be-b25f-62ef2e2aa0d0 Portugal (PT) | 5160fe50-30eb-4851-a4ad-c7489bce1f81 Netherlands (NL) | 4c33881f-f0a2-4ab4-8b05-80f0dc6957d1 Estonia (EE) | 7a8aa60f-fb7b-4633-9554-857968df1c0b Greece (GR) | b9e146ff-487a-40be-b25f-62ef2e2aa0d0 Portugal (PT) | ea73ce68-7db5-4d60-961b-2590dc8126fd Sweden (SE) | ceb27245-9af4-4fb1-b449-dc81ee39b704 Germany (DE) | 047a76d8-ead0-4265-bfa2-ca814a2e94a9 Germany (DE) | 24be2c1a-d0a0-489b-9e49-9b1b683e7486 France (FR) | 6f275054-5b49-46ae-b8a4-f437da98c26b Netherlands (NL) | 0c235e17-44de-43ef-857f-e2b2acfec393 Spain (ES) | 4e491c2d-d697-4758-ae23-de5d61949d1c Netherlands (NL) | 0417799a-9290-4abf-abf6-7774a98a30b1 Bulgaria (BG) | 2eca5665-1d25-4516-8b70-b764a7bdf9a5 Sweden (SE) | 4e491c2d-d697-4758-ae23-de5d61949d1c Netherlands (NL) | 67bee0e5-9901-4ef0-9128-7849a7b0e517 Poland (PL) | 37737179-f4ca-49f4-9dc8-1b69cef21c3e France (FR) | ea73ce68-7db5-4d60-961b-2590dc8126fd Sweden (SE) | ceb27245-9af4-4fb1-b449-dc81ee39b704 Germany (DE) | 047a76d8-ead0-4265-bfa2-ca814a2e94a9 Germany (DE) | 24be2c1a-d0a0-489b-9e49-9b1b683e7486 France (FR) | 6f275054-5b49-46ae-b8a4-f437da98c26b Netherlands (NL) | 0c235e17-44de-43ef-857f-e2b2acfec393 Spain (ES)
Environmental Information
Breakers - Packaging disposal information
E-Number (Finland)
3640524
E-Number (Norway)
4379206
E-Number (Sweden)
3182431
EAN
8015644013080
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.133 kg
Package Level 1 EAN
8015644013080
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In)
63 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
630 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA | (230 V AC) 50 kA | (240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 15 kA | (525 V AC) 11 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA | (230 V AC) 65 kA | (240 V AC) 65 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 30 kA | (525 V AC) 22 kA | (690 V AC) 6 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
44.1...63 A
Short-Circuit Performance Level
N
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
63 A rated current with a setting range of 44.1 to 63 A enables precise protection for motor feeds and transformer circuits, reducing nuisance trips and allowing calibration to load profiles. In practice, panel engineers can tailor the protection to actual demand without oversizing devices, improving safety margins and energy efficiency. With a rated ultimate short-circuit breaking capacity up to 65 kA and service capacity up to 50 kA, this XT1 MCCB delivers safe isolation across a wide voltage range up to 690 V. Its IEC 60947-2 compliance and opening times around 30 ms keep transient faults from propagating, minimizing downtime in critical feeders. Thermomagnetic release TMD with adjustable setting supports reliable coordination with upstream protection, while fixed front terminals simplify wiring and maintenance. The device accepts busbars 45.5 to 80 mm², and its 6 N·m tightening torque ensures solid connections in demanding environments. Low power loss per pole (4.3 W) and high durability ratings—up to 25,000 mechanical cycles and 8,000 electrical cycles—translate into higher uptime and reduced thermal stress in control panels. Environmental and regulatory support is strong with RoHS, REACH, CMRT, SCIP, and EPD disclosures, easing OEM supply chain and end-user compliance.

Get a Quick Quote for a ABB 1SDA067414R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067414R1? Enquire Now

FAQs

Install with front terminals using a busbar of 45.5 to 80 mm², secure connections with a 6 N·m tightening torque, and wire per the circuit diagram for XT1. Use the M6 main circuit screwdriver for terminations and ensure alignment with the panel busbar to maintain early fault isolation and reliable performance.
Key ratings include 63 A nominal current, 690 V rated operational voltage, 8 kV rated impulse withstand, setting range 44.1–63 A, and short-circuit capacities up to 65 kA Icu and 50 kA Ics depending on voltage. These enable correct coordination with feeders and transformers in low-voltage distribution.
Yes. The XT1 3P MCCB is specifically designed for transformer and distribution protection, offering 3-pole construction, front-terminal wiring, and TMD release to coordinate with upstream protection, reducing the risk of cascading faults in LV transformer networks.
The device includes CE Declaration of Conformity, GL and LR certificates, RoHS and REACH declarations, CMRT and SCIP references, and an EPD for environmental performance. UL and VDE do not require additional certifications for this model per its documentation.
It delivers 4.3 W power loss per pole, electrical durability up to 8,000 cycles, and mechanical durability up to 25,000 cycles, supporting uptime in demanding environments. Front-terminal design simplifies wiring and reduces commissioning time, contributing to lower total cost of ownership.