ABB 1SDA067416R1 Moulded Case Circuit Breaker - XT1
Part Number: 1SDA067416R1
Quick Summary
ABB Moulded Case Circuit Breaker XT1 is designed to protect and control low-voltage power circuits in industrial automation applications. Engineers often struggle with nuisance trips and downtime when balancing fast protection with reliable operation in control panels. This device leverages IEC 60947-2 conformity and CE compliance, along with LR and GL certifications, to deliver traceability and dependable performance. By integrating a robust front-terminal design and a configurable protection release, it supports safer, more maintainable switchgear while aligning with SACE Tmax XT families and sustainability programs. The result is a strong value proposition for panel builders seeking reliability, efficiency, and regulator-ready compliance in a cost-competitive package.
Product Information
Extended Description
1SDA067416R1 ABB: C.BREAKER TMAX XT1N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 100-1000 A
Country of Origin
Italy (IT)
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
9dc23701-0389-4d5d-9536-ba4ecc672f9f Italy (IT)
Simplified SCIP
dd3b120b-cdd6-4746-84e1-3b6ba8deac82 Germany (DE) | 8ebd8f62-f8d3-47fd-bae4-333e0a218076 Greece (GR) | db9cca29-2669-426f-bf76-0e2f3f91228f Portugal (PT) | 01cd358c-7878-4350-a8cb-ad98bcdf704c Bulgaria (BG) | b0a036f2-b8f0-4f7f-aefc-8d094fa47899 Sweden (SE) | 996ed7e4-edc7-4d81-acaa-2cb3aad20176 Poland (PL) | 8fd3fa87-f754-4249-8c2f-b59e41939151 France (FR) | c53d77de-041e-4093-a986-0c6cc61f57c5 Sweden (SE) | 84ac0468-5c88-4c5d-8651-f235b69841f9 Norway (NO) | fbb53485-dd85-4069-8b43-658e7c5756b5 Finland (FI) | d200e345-117c-45cc-aa41-8ed4a9afed60 Netherlands (NL) | 1a85d563-57df-4b20-b426-89ccb3c219e0 Germany (DE) | e9fc3286-418a-43e6-a8da-5755bebb9679 Denmark (DK) | b375cf2b-78f3-4e1e-ae01-a1a61a24b8a8 Germany (DE) | d6dca289-557a-48dd-b4aa-fd4b82c36b75 Croatia (HR) | 83b9a438-3162-4bc0-be90-1012a3e4b3fc Poland (PL) | 4f0681cb-c9f4-4a2f-abaf-3d07ac967890 Germany (DE) | 3b489665-c6a7-4f01-ac7f-d84483cd1553 France (FR) | e6c6fa22-a8fe-4514-a81d-fcf5be2a7031 Netherlands (NL) | c4a7c5cf-16cb-45a7-8b0f-07ab801af36a Spain (ES) | 83b9a438-3162-4bc0-be90-1012a3e4b3fc Poland (PL) | 84ac0468-5c88-4c5d-8651-f235b69841f9 Norway (NO) | fbb53485-dd85-4069-8b43-658e7c5756b5 Finland (FI) | b0a036f2-b8f0-4f7f-aefc-8d094fa47899 Sweden (SE) | 2bcd0110-606e-4b4a-96e7-796264c5d0b9 Netherlands (NL) | 996ed7e4-edc7-4d81-acaa-2cb3aad20176 Poland (PL) | 8fd3fa87-f754-4249-8c2f-b59e41939151 France (FR) | c53d77de-041e-4093-a986-0c6cc61f57c5 Sweden (SE) | 8b19cf35-ed11-4fe7-8969-08b832056cec Germany (DE) | 3acf60b8-4063-465a-b3fd-a4c165e3f530 Czech Republic (CZ) | 5dc72b3c-ae87-4b2b-b761-495b6eb5d7eb Poland (PL) | cb2acb5b-5523-4886-9a78-19a9c1e14bee Netherlands (NL) | 1216d8d6-e907-4c14-bafd-557686032dbe Netherlands (NL) | 87f2c02c-07fc-4c8f-9140-875e6fa9b620 Estonia (EE) | 8ebd8f62-f8d3-47fd-bae4-333e0a218076 Greece (GR) | db9cca29-2669-426f-bf76-0e2f3f91228f Portugal (PT) | 8b19cf35-ed11-4fe7-8969-08b832056cec Germany (DE) | 4f0681cb-c9f4-4a2f-abaf-3d07ac967890 Germany (DE) | 3b489665-c6a7-4f01-ac7f-d84483cd1553 France (FR) | e6c6fa22-a8fe-4514-a81d-fcf5be2a7031 Netherlands (NL) | c4a7c5cf-16cb-45a7-8b0f-07ab801af36a Spain (ES) | 2bcd0110-606e-4b4a-96e7-796264c5d0b9 Netherlands (NL) | 01cd358c-7878-4350-a8cb-ad98bcdf704c Bulgaria (BG) | d200e345-117c-45cc-aa41-8ed4a9afed60 Netherlands (NL) | 1a85d563-57df-4b20-b426-89ccb3c219e0 Germany (DE) | e9fc3286-418a-43e6-a8da-5755bebb9679 Denmark (DK) | b375cf2b-78f3-4e1e-ae01-a1a61a24b8a8 Germany (DE) | d6dca289-557a-48dd-b4aa-fd4b82c36b75 Croatia (HR) | 3acf60b8-4063-465a-b3fd-a4c165e3f530 Czech Republic (CZ) | 5dc72b3c-ae87-4b2b-b761-495b6eb5d7eb Poland (PL) | cb2acb5b-5523-4886-9a78-19a9c1e14bee Netherlands (NL) | 1216d8d6-e907-4c14-bafd-557686032dbe Netherlands (NL) | 87f2c02c-07fc-4c8f-9140-875e6fa9b620 Estonia (EE)
Environmental Information
Breakers - Packaging disposal information
E-Number (Finland)
3640527
E-Number (Norway)
4379208
E-Number (Sweden)
3182429
EAN
8015644013103
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.133 kg
Package Level 1 EAN
8015644013103
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 7 W
Rated Current (In)
100 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1000 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA | (230 V AC) 50 kA | (240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 15 kA | (525 V AC) 11 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA | (230 V AC) 65 kA | (240 V AC) 65 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 30 kA | (525 V AC) 22 kA | (690 V AC) 6 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
70...100 A
Short-Circuit Performance Level
N
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
Catalogue SACE Tmax XT | SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | Catalogue (.PDF) [ZH] Tmax XT MCCB | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers | Catalogue (.PDF) [ZH] Tmax XT Technical Characteristics
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front terminals and fixed three-pole XT1 design streamline wiring and panel layout. Business Impact: Reduces installation time and minimizes wiring errors, improving first-pass assembly and ongoing serviceability. Application: Ideal for new switchgear and control panels in 690 V systems across manufacturing lines. Feature: TMD release with a 70–100 A setting range provides adjustable protection. Business Impact: Enables precise coordination with downstream protection devices, reducing nuisance trips and unplanned downtime. Application: Suitable for motor control centers and transformer protection where setpoint tailoring is critical. Feature: Rated 690 V and 100 A with 50/60 Hz compatibility. Business Impact: Supports global deployment in mixed-voltage facilities, lowering spare parts and training needs. Application: Common in European and North American industrial plants with varied electrical environments. Feature: High short-circuit capability (Ics and Icu) across voltage ranges. Business Impact: Delivers reliable interruption during faults, protecting equipment and safeguarding personnel. Application: Essential for feeders and distribution panels with dense fault risk. Feature: Busbar connection (45.5–80 mm²), 6 N·m tightening torque, and front-terminal configuration. Business Impact: Ensures solid, repeatable connections with reduced maintenance, simplifying field servicing. Application: Fits standard busbar layouts and cabinet designs in new builds and refurbishments. Feature: Environmental and compliance options including RoHS, REACH, EPDs, and recyclability. Business Impact: Supports sustainability programs and regulatory reporting while easing end-of-life planning. Application: Useful for OEMs pursuing green manufacturing credentials and customer ESG goals.
Get a Quick Quote for a ABB 1SDA067416R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067416R1?
Enquire Now
FAQs
Installation is straightforward with front-terminal access and 3P configuration. Ensure the busbar cross‑section is within 45.5 to 80 mm² and torque each terminal to 6 N·m. Use the 690 V rated insulation and verify conformity to IEC 60947-2 during commissioning to ensure safe operation and long-term reliability.
The device is rated for 100 A nominal current, 690 V rated voltage, 50/60 Hz, with Icu up to 65 kA and Ics up to 50 kA depending on voltage level. It supports a 70–100 A setting range for the release and uses a TM release type, enabling precise fault protection in mixed-voltage panels.
Yes. The XT1 three-pole design with front terminals is optimized for 3P protection in switchgear and control cabinets. It provides reliable interlock with front wiring, simplifies installation, and supports high fault current scenarios typical in manufacturing lines and transformers.
This product holds CE conformity (EC Declaration of Conformity Tmax XT1), and demonstrates traceability with GL and LR certificates. It complies with IEC 60947-2 standards and is RoHS/REACH compliant, aligning with European regulatory requirements for low-voltage circuit breakers.
The XT1 design reduces wiring time and maintenance overhead thanks to front-terminal accessibility and robust mechanical durability. Its high Icu/Ics ratings protect downstream assets, reducing unplanned downtime. Additionally, RoHS/EPD commitments support sustainability goals, potentially lowering total cost of ownership over the equipment lifecycle.