ABB 1SDA067419R1 Moulded Case Circuit Breaker - 4P XT1N IEC60947-2
Part Number: 1SDA067419R1
Quick Summary
ABB 1SDA067419R1 is a 4-pole molded case circuit breaker for protecting low-voltage distribution panels. Engineers often struggle to balance safety, reliability, and easy maintenance when fitting protective devices into compact switchgear. This XT1N unit complies with IEC 60947-2 and CE, with GL and LR certificates ensuring global applicability. By combining front-terminal installation, a configurable 22.4–32 A setting range, and a robust thermomagnetic release, it reduces downtime and supports lifecycle cost targets. For industrial automation projects, it pairs with SACE Tmax XT line and ABB EcoSolutions to meet sustainability metrics.
Product Information
Extended Description
1SDA067419R1 ABB: C.BREAKER TMAX XT1N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 32-450 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
f9bd9468-5125-4431-8584-a57b00bea951 Italy (IT)
Simplified SCIP
a6cdfadd-e966-4693-b691-e54ccb40925a Belgium (BE) | a90c82eb-b939-4187-9eb5-541db46c0370 France (FR) | b6e43b65-ba0d-4289-8c2f-fec23cb26b73 Spain (ES) | e89f486c-28e2-4e40-bd40-34ee27366375 Germany (DE) | 8fa8b81b-84ed-4353-a426-5d89492bd813 Czech Republic (CZ) | 325b21bf-6b47-47b3-876c-e43123a11e41 Germany (DE) | d2dd1ec9-bc62-4226-9658-2220ad1a4204 Croatia (HR) | 0b06b3b9-00c8-4421-b742-67fc2c9bb176 Germany (DE) | 94dac7fb-2160-4d83-9374-1a7a08924203 Sweden (SE) | 62f1a221-6a1a-4f97-abe6-478502816b25 Hungary (HU) | ce10055e-1964-442f-b72a-c68b67c2495e Germany (DE) | 0f806b46-eb93-46d8-9f3e-909ad906e508 Portugal (PT) | 827ba498-b24a-4ade-a6d7-07aabe245409 Poland (PL) | 23a869b6-9efb-4426-9fbd-0e9c66238e8b Poland (PL) | 19c6c082-7a0f-43f7-b23f-76ec4a9f4e33 Bulgaria (BG) | 998fabec-f3f1-423e-b293-941c68e3d327 France (FR) | e03713e9-d8fa-4413-bef5-f80de83f8837 Germany (DE) | 9ce5449e-6dec-4eb9-be25-3d0ebd8ac527 Greece (GR) | d1ade6f7-8b28-4c13-b4f0-3911ee7648e8 Denmark (DK) | 0db44ebf-bb02-44a7-a0ed-84a75cd1f43b Estonia (EE) | 747672de-9ea5-4e0c-83bf-d44dc599a20d Belgium (BE) | 1b40320d-ce6a-4bb7-bc0a-95aa81fae957 Hungary (HU) | f22229db-3fe4-46e9-b7fc-51079f8a6102 Poland (PL) | c01722b9-e994-42b1-a489-df33c5b0dbf2 Finland (FI) | 3f871474-4709-46ac-a549-0741e68ce02d Netherlands (NL) | 89f15a33-e498-4a1b-ba2a-67b747aa7a50 Norway (NO) | 88a860a6-8abb-43a2-8500-84ad904739da Sweden (SE)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1NE4032AFF000XXX
E-Number (Finland)
3640539
E-Number (Norway)
4379232
EAN
8015644013134
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.446 kg
Package Level 1 EAN
8015644013134
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.1 W
Rated Current (In)
32 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA | (230 V AC) 50 kA | (240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 15 kA | (525 V AC) 11 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA | (230 V AC) 65 kA | (240 V AC) 65 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 30 kA | (525 V AC) 22 kA | (690 V AC) 6 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
22.4...32 A
Short-Circuit Performance Level
N
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The four-pole XT1N construction with front terminals and a thermomagnetic release delivers fast, safe installation and selective tripping, reducing nuisance faults during busy industrial shifts and improving panel reliability. This directly supports installers and maintenance teams by simplifying wiring and speeding fault isolation in space-constrained panels. With a 32 A rated current and 690 V insulation, it handles demanding low‑voltage feeders in factories, data centers, and process lines, delivering predictable protection and minimizing downstream equipment damage. The device offers a high short‑circuit withstand capacity (Icu up to 65 kA; Ics up to 50 kA depending on voltage), translating into reduced energy losses and lower repair costs after faults. Compatibility with 45.5–80 mm² busbars, front‑mounted terminals, and a 6 N·m tightening torque ensures straightforward retrofits and fast commissioning. Sustainability and compliance are enhanced by EPD, REACH, and RoHS declarations, along with SCIP listings and eco‑packaging guidance, supporting regulatory programs and corporate ESG goals.
Get a Quick Quote for a ABB 1SDA067419R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067419R1?
Enquire Now
FAQs
The device uses front terminal connections with bolt terminals and supports busbars from 45.5 to 80 mm². It requires a M6 screwdriver and a tightening torque of 6 N·m, making retrofits straightforward in standard 4P low‑voltage panels.
Rated current is 32 A, rated voltage 690 V, and it provides substantial fault-current protection with Icu up to 65 kA and Ics up to 50 kA depending on system voltage. Setting range is adjustable from 22.4 to 32 A, with 50/60 Hz operation.
Yes. Rated operational voltage is 690 V AC (and 500 V DC in applicable configurations), and the XT1N design supports mixed AC/DC loads with reliable protection and selective tripping.
It conforms to IEC 60947-2, bears CE conformity, and carries GL and LR certificates, along with DoC and EPD documentation. This combination supports global deployment and regulatory compliance.
Electrical durability is rated up to 8000 cycles with mechanical durability up to 25,000 cycles, enabling long service life in demanding environments while maintaining protective performance and reducing maintenance intervals.