ABB 1SDA067426R1 Moulded Case Breaker - XT1N 160 IEC60947-2

Part Number: 1SDA067426R1
Manufacturer
ABB
Part number
1SDA067426R1

Quick Summary

ABB 1SDA067426R1 Moulded Case Breaker is a 4-pole XT1N protection device for industrial power distribution. Many engineers face wiring complexity and slow fault response when retrofitting or expanding switchgear. This unit complies with IEC 60947-2 and CE, and ABB provides transparent environmental declarations (EPD) and end‑of‑life guidance. Front-terminals and a fixed 4P design streamline installation while reducing field wiring time and potential connection errors. The product offers 160 A rated current with a setting range of 112–160 A and a 690 V rated operational voltage, making it versatile for power distribution scenarios. This translates to lower total cost of ownership through faster commissioning and improved uptime while supporting sustainability goals.

Product Information

Extended Description

1SDA067426R1 ABB: C.BREAKER TMAX XT1N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 160-1600 A NEUTRAL = 50% PHASES
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
94fc082b-5d76-4eeb-8e15-5bc418ea47af Italy (IT)
Simplified SCIP
fa3b011f-e8ce-44e9-b47c-88318fee50f7 Germany (DE) | 3ec8def3-26e1-4ea0-aa32-57f71b742262 Netherlands (NL) | 75bbca28-e587-474a-9cd9-93bd683eb6bd Poland (PL) | 0f3c025e-76a4-42f8-a532-77289e6ce527 France (FR) | 7e0ca652-f8ae-4579-b473-9a158dafbc5c Sweden (SE) | bac36a39-01c4-4a6f-af9e-9b7161d1e1bc Germany (DE) | c51b95da-3991-4a00-8ef2-a296e7f49316 Germany (DE) | f63704f1-3070-4977-8e44-350fb8cf5b76 France (FR) | 35ec6a18-d596-47b6-bac9-d899ecfe1a71 Netherlands (NL) | 60ba9153-13fb-4c7d-847d-fd8687e3684f Spain (ES) | c22759bd-e767-42ec-a60c-4a0bf8d08046 Poland (PL) | 8176d198-3736-4051-a517-95d2c29d4933 Norway (NO) | 25687a92-dfaa-486f-9862-2989dc1e4d20 Finland (FI) | f63704f1-3070-4977-8e44-350fb8cf5b76 France (FR) | 35ec6a18-d596-47b6-bac9-d899ecfe1a71 Netherlands (NL) | 60ba9153-13fb-4c7d-847d-fd8687e3684f Spain (ES) | 3ec8def3-26e1-4ea0-aa32-57f71b742262 Netherlands (NL) | 35fcd6a6-24d8-4ae4-9584-618010b0dd12 Bulgaria (BG) | 3bff1077-073c-4af5-8b20-c327726bb6ec Sweden (SE) | cfa3eca7-9354-475b-a8cf-e1ee7abe2bf0 Estonia (EE) | e6c36f1a-665b-4b63-aeed-1f21831af460 Greece (GR) | de8c84de-a508-41dd-a934-57ef560cec5e Portugal (PT) | 7e0ca652-f8ae-4579-b473-9a158dafbc5c Sweden (SE) | bac36a39-01c4-4a6f-af9e-9b7161d1e1bc Germany (DE) | c51b95da-3991-4a00-8ef2-a296e7f49316 Germany (DE) | e6265f58-711e-4fd2-bef1-0881d3c8addf Netherlands (NL) | 27c0fb6e-d769-4603-9bf6-3ff184b9c964 Germany (DE) | 53a6811b-361d-42c0-8fdd-ceafeda65111 Denmark (DK) | b53d8468-4e87-491b-b3f7-b7aa24061656 Germany (DE) | 9f412e57-8038-4a0e-81da-a6d522566174 Croatia (HR) | 1d62ba95-6642-4c2c-ab93-b59bb2a2ee4d Czech Republic (CZ) | 4c6f5836-0888-465b-b68d-ffa17714d0df Poland (PL) | c22759bd-e767-42ec-a60c-4a0bf8d08046 Poland (PL) | 8176d198-3736-4051-a517-95d2c29d4933 Norway (NO) | 25687a92-dfaa-486f-9862-2989dc1e4d20 Finland (FI) | e6265f58-711e-4fd2-bef1-0881d3c8addf Netherlands (NL) | 27c0fb6e-d769-4603-9bf6-3ff184b9c964 Germany (DE) | 53a6811b-361d-42c0-8fdd-ceafeda65111 Denmark (DK) | b53d8468-4e87-491b-b3f7-b7aa24061656 Germany (DE) | 9f412e57-8038-4a0e-81da-a6d522566174 Croatia (HR) | 1d62ba95-6642-4c2c-ab93-b59bb2a2ee4d Czech Republic (CZ) | 4c6f5836-0888-465b-b68d-ffa17714d0df Poland (PL) | 924d376e-341e-48de-a6bd-e4907f9d0cf8 Netherlands (NL) | d353cc07-7fe6-457f-a644-d0f476b52145 Netherlands (NL) | 0f3c025e-76a4-42f8-a532-77289e6ce527 France (FR) | 35fcd6a6-24d8-4ae4-9584-618010b0dd12 Bulgaria (BG) | 3bff1077-073c-4af5-8b20-c327726bb6ec Sweden (SE) | 75bbca28-e587-474a-9cd9-93bd683eb6bd Poland (PL) | 924d376e-341e-48de-a6bd-e4907f9d0cf8 Netherlands (NL) | d353cc07-7fe6-457f-a644-d0f476b52145 Netherlands (NL) | cfa3eca7-9354-475b-a8cf-e1ee7abe2bf0 Estonia (EE) | e6c36f1a-665b-4b63-aeed-1f21831af460 Greece (GR) | de8c84de-a508-41dd-a934-57ef560cec5e Portugal (PT)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1NEN160AFF000XXX
E-Number (Finland)
3640535
EAN
8015644013202
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.54 kg
Package Level 1 EAN
8015644013202
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 15 W
Rated Current (In)
160 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1600 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA | (230 V AC) 50 kA | (240 V AC) 50 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 18 kA | (500 V AC) 15 kA | (525 V AC) 11 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA | (230 V AC) 65 kA | (240 V AC) 65 kA | (380 V AC) 36 kA | (415 V AC) 36 kA | (440 V AC) 36 kA | (500 V AC) 30 kA | (525 V AC) 22 kA | (690 V AC) 6 kA | (250 V DC) 2 Poles in Series 36 kA | (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
112...160 A
Short-Circuit Performance Level
N
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front terminals and fixed four-pole configuration. Business Impact: Simplified wiring, safer maintenance, and reduced installation time, especially in compact switchgear layouts. Application: Panel builders and retrofit projects benefit from quicker commissioning and fewer field wiring errors. Feature: Setting range 112–160 A with a 160 A nominal rating. Business Impact: Improved coordination with upstream protection and selective tripping, minimizing nuisance outages. Application: Feeder and transformer protection where precise current coordination is critical. Feature: High voltage capability with rated operational voltage 690 V AC and insulation up to 800 V. Business Impact: Broad compatibility with industrial power networks and robust fault handling across equipment. Application: Commercial and heavy industry panel systems requiring universal mains protection. Feature: Short-circuit performance and reliability with Ics up to 65 kA and Ii up to 1600 A. Business Impact: Strong fault-clearing capability reduces arc flash risk and equipment damage. Application: Motors, drives, and essential bus bars in demanding environments. Feature: Comprehensive environmental and compliance package including IEC 60947-2, CE, RoHS/REACH, EPD, and SCIP. Business Impact: Supports regulatory compliance, end‑of‑life planning, and responsible supply chain management. Application: Global installations with strict sustainability targets. Feature: Compact footprint and weight (101.6 mm W, 130 mm H, 70 mm D; 1.4 kg). Business Impact: Space-efficient installation and easier handling during assembly. Application: Customer panels with limited enclosure space.

Get a Quick Quote for a ABB 1SDA067426R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067426R1? Enquire Now

FAQs

Install with front terminals using the standard 6 N·m tightening torque per terminal. The unit is a fixed 4P design with front-access terminals, simplifying wiring runs and reducing risk of loose connections. Ensure busbar connections are within the AC/DC rated capacity and follow the XT1 installation instructions for correct mounting and clearance.
The device offers a setting range of 112–160 A and a rated instantaneous trip of 1600 A, enabling selective coordination with upstream protective devices. When integrating, align the Iu and Ic values with upstream protection schemes and consider system fault levels to minimize nuisance trips while maintaining fast fault clearance.
Yes, it is rated for 690 V AC operation with Ui of 800 V and Uf appropriate for 50/60 Hz systems. Key specs include 4P configuration, 160 A In, Ics up to 65 kA, and a compact 101.6 mm width. It supports front-terminal mounting and a 6 N·m tightening torque per terminal, making it compatible with standardmedium-voltage panel architectures.
The device complies with IEC 60947-2 and CE, and ABB provides REACH and RoHS declarations, an Environmental Product Declaration (EPD) for Tmax XT XT1, and SCIP references for end‑of‑life data. These documents support regulatory compliance, sustainability reporting, and responsible disposal planning at end of life.
Expect a lifespan aligned with standard XT1N durability specs: electrical durability at up to 8000 cycles and mechanical durability up to 25,000 cycles at rated conditions, plus documented disassembly instructions for end‑of‑life handling. Regular inspections should verify torque on terminals and correct operation of the TMD release to maintain reliability and uptime.