ABB 1SDA067432R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067432R1
Quick Summary
ABB 1SDA067432R1 Moulded Case Circuit Breaker protects 690 V industrial power distribution networks. Engineers struggle with front-terminal access and reliable short-circuit protection in compact panel spaces. This XT1S device aligns with IEC 60947-2, CE with DoC, RoHS/REACH, and EPD pathways for sustainable design. Supporting Tmax XT family compatibility, it delivers predictable protection with a 44.1–63 A setting range and front-terminal convenience, enabling faster installation and reduced downtime. Its 80 kA short-circuit ratings and 690 V operating voltage meet modern industrial demands, while 3P wiring and 4p drawing support align with standard control panels. For panel builders and maintenance teams, this MCCB offers robust protection with simple, safer integration into existing power distribution schemes.
Product Information
Extended Description
1SDA067432R1 ABB: C.BREAKER TMAX XT1S 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 63-630 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
ce8f8891-6bc3-4b61-ab84-65b55800b12c Italy (IT)
Simplified SCIP
0f485dd2-345b-47b5-aeab-6dcc5440ef9f Germany (DE) | c9cc1f95-e9ad-45fb-af3a-537eeea9a165 Poland (PL) | 1ccbd741-adb3-4f10-a52c-b1bd20a388f5 Norway (NO) | 1391e5c1-5120-4220-8bb8-3d8552fe799e Finland (FI) | 38d0cd2b-989e-4b24-bed5-62dffbdfaa08 Netherlands (NL) | bb463840-133b-4cbd-ad31-af6a9c57cb88 Germany (DE) | 0fee1a6e-6a4d-42de-9d4c-c1b6bd41ac8f Denmark (DK) | 89f9f307-8d6f-49ba-8a3f-7ac5805036d8 Germany (DE) | 20fe8453-f873-4fc7-b77f-6f6e2602a0e3 Croatia (HR) | b0944749-d3ec-4d7b-ad13-5fdee17bb549 Czech Republic (CZ) | b7986f4a-5532-47ea-b566-d8419c037fe4 Poland (PL) | 646bb9c1-f1ff-415b-96dc-dec2582724a2 Netherlands (NL) | 692513ce-7bf8-4288-b905-97ef8bd55806 Netherlands (NL) | b683d435-63d8-4f85-835c-f7d575fa2ca1 Spain (ES) | 7a6ae108-4ae3-445f-9d24-67093624b36d Netherlands (NL) | fe0cc92e-2520-4b37-aee1-3e9999a6caaa Portugal (PT) | 51814f2d-932c-4674-a7be-9e65af785725 Netherlands (NL) | a24511f0-eef9-47b9-a93a-be419cae331c Estonia (EE) | f9bbc942-6b2e-4f31-b653-08b461ec4b89 Greece (GR) | e736bd0c-83bf-4e74-aa67-c54fd149fd5d Sweden (SE) | c66859ea-22de-4e3f-a6ae-4d94f96182a0 Germany (DE) | 0dfafdd1-adb5-4d45-90f9-6b8b900f3b89 Germany (DE) | 6e73b777-5c04-4b2f-bbb0-a93d6931b927 France (FR) | a24511f0-eef9-47b9-a93a-be419cae331c Estonia (EE) | f9bbc942-6b2e-4f31-b653-08b461ec4b89 Greece (GR) | fe0cc92e-2520-4b37-aee1-3e9999a6caaa Portugal (PT) | 7ac1fce6-4c9e-4303-96ba-631d35c69185 Bulgaria (BG) | c5a614be-fe83-4ba8-8ed1-005a446889af Sweden (SE) | 85ebc361-f4dd-428a-9821-fab80f8db294 Poland (PL) | d289bc2c-e60b-4f5e-9237-b3c55ba8672d France (FR) | 0fee1a6e-6a4d-42de-9d4c-c1b6bd41ac8f Denmark (DK) | 89f9f307-8d6f-49ba-8a3f-7ac5805036d8 Germany (DE) | 20fe8453-f873-4fc7-b77f-6f6e2602a0e3 Croatia (HR) | b0944749-d3ec-4d7b-ad13-5fdee17bb549 Czech Republic (CZ) | b7986f4a-5532-47ea-b566-d8419c037fe4 Poland (PL) | 646bb9c1-f1ff-415b-96dc-dec2582724a2 Netherlands (NL) | 51814f2d-932c-4674-a7be-9e65af785725 Netherlands (NL) | 7ac1fce6-4c9e-4303-96ba-631d35c69185 Bulgaria (BG) | c5a614be-fe83-4ba8-8ed1-005a446889af Sweden (SE) | 7a6ae108-4ae3-445f-9d24-67093624b36d Netherlands (NL) | 85ebc361-f4dd-428a-9821-fab80f8db294 Poland (PL) | d289bc2c-e60b-4f5e-9237-b3c55ba8672d France (FR) | e736bd0c-83bf-4e74-aa67-c54fd149fd5d Sweden (SE) | c66859ea-22de-4e3f-a6ae-4d94f96182a0 Germany (DE) | 0dfafdd1-adb5-4d45-90f9-6b8b900f3b89 Germany (DE) | 6e73b777-5c04-4b2f-bbb0-a93d6931b927 France (FR) | 692513ce-7bf8-4288-b905-97ef8bd55806 Netherlands (NL) | b683d435-63d8-4f85-835c-f7d575fa2ca1 Spain (ES) | c9cc1f95-e9ad-45fb-af3a-537eeea9a165 Poland (PL) | 1ccbd741-adb3-4f10-a52c-b1bd20a388f5 Norway (NO) | 1391e5c1-5120-4220-8bb8-3d8552fe799e Finland (FI) | 38d0cd2b-989e-4b24-bed5-62dffbdfaa08 Netherlands (NL) | bb463840-133b-4cbd-ad31-af6a9c57cb88 Germany (DE)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SE3063AFF000XXX
E-Number (Norway)
4309621
EAN
8015644013264
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.17 kg
Package Level 1 EAN
8015644013264
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In)
63 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
630 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 37.5 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (240 V AC) 85 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 36 kA | (525 V AC) 35 kA | (690 V AC) 8 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
44.1...63 A
Short-Circuit Performance Level
S
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal design and 3P configuration enable quick, safe installation in tight panel spaces. Business Impact: Reduces wiring time and minimizes panel rework during integration. Application: Ideal for compact switchgear cabinets and control panels in manufacturing lines. Feature: Thermomagnetic release (TMD) with a 44.1–63 A setting range provides precise overcurrent protection. Business Impact: Improves selective tripping and prevents nuisance outages, boosting line availability. Application: Suitable for motor starter circuits and critical power distribution loads. Feature: High short-circuit capability (Ics up to 80 kA) and rated operational voltage of 690 V. Business Impact: Enhances system resilience against severe faults, lowering downtime and equipment damage. Application: Needed for feeders protecting transformers and large drives. Feature: Compliance and sustainability credentials (IEC60947-2, CE, RoHS, REACH, EPD). Business Impact: Eases regulatory approvals and supports sustainability reporting. Application: Meets European procurement requirements and green design targets. Feature: Durable mechanical and electrical life (up to 25,000 cycles mechanically, 8,000 cycles per hour electrically). Business Impact: Extends asset life and reduces maintenance interruptions. Application: Suited for continuous operation in process industries and data centers. Feature: Front-accessible terminals with 6 N·m tightening torque and busbar compatibility (45.5–80 mm²). Business Impact: Facilitates faster, safer field-term connections. Application: Enables rapid retrofit into existing low-voltage distribution panels.
Get a Quick Quote for a ABB 1SDA067432R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067432R1?
Enquire Now
FAQs
This unit is designed for front-terminal mounting with a tightening torque of 6 N·m. Use busbars in the 45.5–80 mm² range and ensure proper alignment of the 3P poles. When installing, verify that the enclosure accommodates 76.2 mm width and 130 mm height to maintain safe clearances. The front-terminal design simplifies field wiring and reduces assembly time while maintaining mechanical integrity.
The device offers a rated current of 63 A, rated insulation voltage of 800 V, and rated operational voltage of 690 V. It provides an instantaneous short-circuit setting up to 630 A and a short-circuit breaking capacity Ics up to 80 kA across relevant voltages. It supports AC/DC current types and includes a thermomagnetic release (TMD) with a 44.1–63 A setting range for precise protection.
Yes. With 690 V operating capability, 3P configuration, front terminals, and 80 kA Ics/Icu ratings, this XT1S MCCB is well-suited for data centers, manufacturing lines, and industrial machinery protection. Its compact front-terminal footprint enables easy retrofits in panel boards, while the Tmax XT family compatibility ensures consistent protection coordination in mixed installations.
The device complies with IEC 60947-2 and carries CE Declarations of Conformity. It is RoHS and REACH compliant, with an Environmental Product Declaration (EPD) pathway for Tmax XT XT1 and related components. Additional certifications include GL and LR certifications, and it references SCIP registrations for European market compliance.
The product delivers predictable, reliable protection with a robust mechanical life (up to 25,000 cycles) and 8,000 electrical cycles per hour, reducing unscheduled outages. Front-terminal design speeds installation and future servicing, cutting labor costs. Overall, the unit helps lower total cost of ownership by minimizing downtime, simplifying compliance reporting, and ensuring stable protection for critical processes.