ABB 1SDA067440R1 Moulded Case Circuit Breaker - TMD
Part Number: 1SDA067440R1
Quick Summary
Moulded Case Circuit Breaker is a reliable protection device for industrial power distribution, safeguarding circuits in manufacturing and processing lines. Engineers struggle with limited panel space, wiring complexity, and precise, repeatable tripping in evolving control architectures. This ABB Tmax XT1S device meets IEC 60947-2 and CE requirements while offering GL and LR certifications for added rigor, plus front-terminal access for fast installation. This translates to faster deployments, safer operations, and lower life cycle costs for your electrical protection schemes, while maintaining compatibility with 45.5-80 mm2 busbars and 690 V systems.
Product Information
Extended Description
1SDA067440R1 ABB: C.BREAKER TMAX XT1S 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 63-630 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
a64a71c8-2a15-484d-aa7f-726507440e44 Italy (IT)
Simplified SCIP
fd03284a-b46f-46b9-af63-69b3b4762aea Germany (DE) | 280ded22-e263-4e3b-b81c-9084d4308385 Poland (PL) | 7b05548a-e015-4945-a79f-2075289b925a Poland (PL) | bf94d655-349c-44b7-bd29-3f75bc860916 Bulgaria (BG) | c5639dac-4194-430c-a23f-3252ebbca1ef Portugal (PT) | b148701a-d8a8-4c5a-b3fa-73c59b7d9174 Hungary (HU) | 35940b5c-2b3e-4270-bb06-e7e2588b2137 Belgium (BE) | 3db23266-a43d-4a48-b738-917d8ef907d2 Spain (ES) | fa34b4e5-6ac3-4154-912d-a510aecaae6a France (FR) | 459dd98a-1407-4239-a2fb-05dca88961c0 Germany (DE) | 3457a8bb-56ed-4ecf-a190-f9bdff93df8c Denmark (DK) | 43573122-88b5-4317-b9b8-08c0212e9206 Sweden (SE) | 08bf8494-6075-4c06-bc4f-84d4fbb5915b Germany (DE) | 5f0b1111-d6a8-474c-8727-03eeac4a21ac Germany (DE) | 913aecfc-7aab-4baa-b645-2130b8975519 Croatia (HR) | 054527a7-cebf-473b-bd8a-ed748d883693 Czech Republic (CZ) | 34621fae-58d0-4e90-ae40-952bbbc2dd12 Germany (DE) | 5d29a269-d245-4a5d-926d-e6dd438fb713 Greece (GR) | c833f4e3-5422-4210-8f33-1c3a1d8010c1 France (FR) | f6a3be32-6ea4-4c7d-b3e9-6ea5abbdcd1d Belgium (BE) | dcdd5d0e-c6d7-489e-81d4-9baa8bdcf944 Estonia (EE) | 48b75ddc-93dc-49ba-9951-af1ca9494921 Hungary (HU) | adafc7c9-e8aa-4762-82fe-c974d4985d62 Poland (PL) | 92a6b06c-f3b1-41e3-a241-8e6ad9d7dbd3 Sweden (SE) | 514cb359-ef47-455e-90f2-c4935727278e Finland (FI) | 7dd0bde2-1f35-45fe-b751-a1fb27f7df16 Norway (NO) | 9e8d7d74-0f78-4696-a3c1-19b336ffd2de Netherlands (NL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SE4063AFF000XXX
E-Number (Norway)
4309721
EAN
8015644013349
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644013349
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.3 W
Rated Current (In)
63 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
630 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 37.5 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (240 V AC) 85 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 36 kA | (525 V AC) 35 kA | (690 V AC) 8 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
44.1...63 A
Short-Circuit Performance Level
S
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front termination and 4-pole XT1 design reduce wiring complexity and enable compact panel layouts. Business Impact: Accelerates installation, reduces panel footprint, and minimizes wiring errors, delivering cost savings on assembly and wiring labor. Application: Suitable for MCCs and switchgear assemblies using busbars from 45.5 to 80 mm². Feature: Thermomagnetic release (TMD) with fixed 4P configuration. Business Impact: Improves selective tripping and protects downstream equipment with fast, reliable responses to overloads and short-circuits. Application: Motor control centers and transformer protection where precise curve settings matter. Feature: Setting range 44.1–63 A with rated current 63 A. Business Impact: Allows precise adaptation to system load without oversizing, reducing wasted energy and thermal stress on conductors. Application: Industrial power distribution feeding machines and lines in mid-scale facilities. Feature: High short-circuit capability (Icu up to 85 kA; Ics up to 80 kA depending on voltage). Business Impact: Provides robust protection for high-energy circuits, improving safety margins and reducing risk of equipment damage. Application: Protective interlock for feeders and distribution panels at 690 V systems. Feature: Front-access terminals and busbar compatibility (45.5–80 mm²) plus 6 N·m tightening torque. Business Impact: Streamlines wiring and torque assurance, improving reliability and maintenance efficiency. Application: Field installation on robust busbar systems in modern control rooms and outdoor enclosures.Feature: Compliance and documentation suite (IEC 60947-2, EC Declaration of Conformity, GL/LR certificates). Business Impact: Eases regulatory acceptance, lowers qualification time for projects, and supports audit readiness. Application: Global deployments requiring certified protection devices with traceable declarations.
Get a Quick Quote for a ABB 1SDA067440R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067440R1?
Enquire Now
FAQs
Installation starts with selecting busbars in the 45.5 to 80 mm² range and ensuring the panel supports 690 V systems. Use the recommended tightening torque of 6 N·m for the front bolts, connect per the wiring diagram, and mount in a well-ventilated enclosure. The four-pole, front-terminal design simplifies wiring runs and accelerates commissioning while maintaining safe clearances.
The device has a rated current of 63 A and a rated voltage of 690 V. Short-circuit performance includes an Ics up to 80 kA and an Icu up to 85 kA depending on voltage conditions. These ratings enable reliable interruption of fault currents in medium- to high-energy circuits, supporting strong protection margins in industrial installations.
Yes, with its 4P XT1 configuration and TMD release, it is well-suited for transformer protection and motor feeder applications. Certifications include IEC 60947-2 compliance, CE declaration, and GL/LR certifications, providing audit-ready documentation and acceptance across many global markets.
Ideal for industrial power distribution boards, motor control centers, transformer feeders, and switchgear assemblies in manufacturing and process plants. The front-terminal design accelerates wiring in compact panels, while the adjustable setting range and high short-circuit ratings support scalable protection as equipment loads grow.
Plan periodic inspections for connections at the front terminals and verify tightening torque (6 N·m) during maintenance. Use the 44.1–63 A setting range to align with system loads and monitor power loss (4.3 W per pole) for thermal management. The device’s IEC 60947-2 compliance and certifications support lower risk and longer service life in regulated environments.