ABB 1SDA067441R1 Moulded Case Breaker - 690V 8kA Icu
Part Number: 1SDA067441R1
Quick Summary
ABB 1SDA067441R1 Moulded Case Breaker protects industrial power distribution against short circuits and overloads, delivering rapid, selective tripping to preserve critical processes. For engineers tasked with panel builds, the front-terminal design and four-pole configuration streamline wiring, reduce assembly time, and improve fault isolation across feeders and transformers. This device complies with IEC60947-2, features CE conformity with the EC Declaration of Conformity, and carries RoHS and REACH declarations, aligning with global safety and sustainability expectations. As part of the SACE Tmax XT ecosystem, it supports scalable protection for transformers, distribution boards, and automated plants, with compatibility across busbars 45.5 to 80 mm² and common M6 tooling for secure, reliable installations.
Product Information
Extended Description
1SDA067441R1 ABB: C.BREAKER TMAX XT1S 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 80-800 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1SE4080AFF000XXX
E-Number (Norway)
4309722
EAN
8015644013356
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.4 kg
Package Level 1 EAN
8015644013356
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
80 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
800 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 50 kA | (415 V AC) 37.5 kA | (440 V AC) 25 kA | (500 V AC) 18 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 85 kA | (230 V AC) 85 kA | (240 V AC) 85 kA | (380 V AC) 50 kA | (415 V AC) 50 kA | (440 V AC) 50 kA | (500 V AC) 36 kA | (525 V AC) 35 kA | (690 V AC) 8 kA | (250 V DC) 2 Poles in Series 50 kA | (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
56...80 A
Short-Circuit Performance Level
S
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The XT1 four-pole fixed-front-terminal design delivers front-access wiring that simplifies panel assembly and future upgrades, reducing installation time and wiring errors. Business impact: faster panel builds, lower labor costs, and improved fault localization during commissioning in industrial power distribution environments. Application: ideal for transformer protection and main feeders in automation facilities, with busbar compatibility from 45.5 to 80 mm² and front-terminal connections that support quick field maintenance. The 690 V rated operational voltage and 80 A nominal current provide reliable protection for medium-size to large drive systems while preserving selectivity with a defined 56–80 A setting range. The device supports RoHS/REACH compliance and IEC60947-2 standards, easing regulatory risk and enabling cost-effective lifecycle management. Durability specs—up to 8000 electrical cycles and 25000 mechanical cycles—translate to long service intervals in high-demand plants. Energy efficiency is reinforced by a low power loss of 4.8 W per pole, contributing to reduced heat and cooling requirements in switchgear cabinets. End-of-life and recyclability considerations are addressed with disassembly instructions and environmental data for sustainable disposal.
Get a Quick Quote for a ABB 1SDA067441R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067441R1?
Enquire Now
FAQs
The XT1 front-terminal design is configured for straightforward wall- or panel-mounting with front-access terminals. Use the standard M6 driver and tighten to 6 N·m per terminal to ensure secure connections and reliable fault clearance in 690 V systems.
Yes. It is rated for 690 V operation. The device provides an ultimate short-circuit breaking capacity (Icu) of up to 8 kA at 690 V, with service-breaking capacity (Ics) up to 80 kA at applicable voltages, supporting robust protection for transformer feeders and distribution panels.
The MCCB complies with IEC 60947-2 and CE declarations. It carries RoHS and REACH declarations for material compliance and sustainability, aligning with global safety and environmental requirements.
Yes. The unit supports front-terminal connections and busbar main circuit capacity from 45.5 to 80 mm², making it suitable for compact, service-friendly panel designs with easy field maintenance.
Maintenance benefits come from the fixed front-terminal design, clear wiring guidance, and disassembly instructions for end-of-life handling. Electrical durability is rated at up to 8000 cycles, mechanical durability up to 25000 cycles, supporting long service intervals in demanding industrial environments.