ABB 1SDA067451R1 Moulded Case Circuit Breaker is a compact, reliable overcurrent protector for industrial power distribution. It helps engineers avoid nuisance trips by combining precise thermal-magnetic release with intent-driven setting ranges. This XT1 device complies with IEC 60947-2 and bears a CE declaration, while GL and LR certifications support global reliability. With 3 poles, front terminals, and a 56–80 A adjustable range, installation is straightforward in retrofit and new builds. EcoSolutions features, recyclability data, and a transparent end-of-life guide support sustainability goals while reducing waste. In practical terms, customers gain shorter outage times, easier maintenance, and predictable safety margins across diverse industrial environments.
Product Information
Extended Description
1SDA067451R1 ABB: C.BREAKER TMAX XT1H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 80-800 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HE3080AFF000XXX
E-Number (Norway)
4379219
EAN
8015644013455
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.14 kg
Package Level 1 EAN
8015644013455
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
80 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
800 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 52.5 kA | (415 V AC) 37.5 kA | (440 V AC) 32.5 kA | (500 V AC) 25 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 52.5 kA | (500 V DC) 3 Poles in Series 52.5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 35 kA | (690 V AC) 10 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
56...80 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Three-pole XT1 design provides robust protection for distribution boards and transformer feeders, reducing fault propagation and improving system availability. Business impact: improved selectivity and faster fault isolation. Application: suitable for 690 V systems in industrial panels. The 56–80 A setting range aligns with common motor and feeder loads, enabling precise coordination with upstream devices and reducing nuisance trips. Application: motor control centers and protected feeders. Front terminals and bolt connections simplify wiring during commissioning and maintenance, improving install time by eliminating rear-access constraints. Business impact: lower labor costs and faster turnarounds. The device offers Ics up to 80 kA and Icu up to 100 kA at lower voltages, delivering high short-circuit resilience across LV applications. Application: transformer feeders and high-demand loads. IEC 60947-2 compliance ensures global acceptance and consistent performance. EcoSolutions features and end-of-life instructions support responsible disposal and lifecycle planning. Each unit weighs 1.1 kg and has compact dimensions (76.2 mm W x 130 mm H x 70 mm D) suitable for space-constrained panels. Business impact: predictable footprint and easier integration with existing layouts. Overall, this MCCB supports reduced energy losses (4.8 W per pole) and safer operation in demanding environments.
Get a Quick Quote for a ABB 1SDA067451R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067451R1?
Enquire Now
FAQs
Use the front bolt terminals designed for busbars 45.5–80 mm2. Tighten each terminal to 6 N·m with a main circuit M6 screwdriver, and mount the device in a standard 3P XT1 configuration. This layout minimizes wiring congestion, simplifies future maintenance, and supports fast commissioning in retrofit and new builds.
Rated current is 80 A with a rated insulation voltage of 800 V and rated operational voltage of 690 V AC / 500 V DC. Short-circuit performance includes Ics up to 80 kA and Icu up to 100 kA at lower voltages (e.g., 220–240 V). These ratings support reliable protection for LV distribution boards and motor feeders in diverse industrial environments.
Yes. The device offers a 56–80 A setting range, three poles, and a TM/TMD release option, enabling selective motor protection and fast fault isolation. Front-terminal design simplifies wiring during commissioning, while the 690 V rating supports transformer feeders. It balances protective speed with coordination to upstream devices for safer, more reliable operation.
It complies with IEC 60947-2 and carries a CE Declaration of Conformity. Certifications include GL and LR, along with REACH, RoHS, CMRT, and TSCA disclosures. The product is supported by EPDs under ABB EcoSolutions and end-of-life guidance to assist regulatory reporting and sustainable procurement activities.
ABB EcoSolutions provides packaging disposal guidance and disassembly instructions for end-of-life handling. The design supports resource-loop closing per EN45555 with a recyclability rate around 55.9%. Environmental data sheets (EPD) and packaging info help meet circular economy targets, while enabling lower total cost of ownership through easier recycling and waste reduction.