ABB 1SDA067453R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067453R1
Quick Summary
ABB 1SDA067453R1 Moulded Case Circuit Breaker is a protective device for low-voltage power distribution in industrial panels. Engineers often struggle with selecting breakers that balance reliable protection, compact footprint, and lifecycle cost across evolving plants. The XT1 Tmax family supports IEC 60947-2 compliance, CE conformity, and LR/GL certifications to validate safety and performance, while offering front-terminal installation and reliable remote operation. This solution delivers predictable tripping, simplified wiring, and robust protection in space-constrained environments, enabling faster panel builds and easier maintenance. By aligning with eco-friendly practices through EPD, RoHS, and recyclability metrics, it also supports sustainability goals alongside cost-effective protection and easy upgrades for the SACE Tmax XT lineup.
Product Information
Extended Description
1SDA067453R1 ABB: C.BREAKER TMAX XT1H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 125-1250 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
257f727a-d73b-4b44-9b03-f660196a0e86 Italy (IT)
Simplified SCIP
5c828b60-5527-4871-961b-d10cab4f90f3 France (FR) | 17a1f22a-6317-4788-bd82-724e76616265 Germany (DE) | e27712b2-6ae0-42c4-99bf-6efdeef3098b Spain (ES) | 6ca28ee4-c3cf-438d-8069-059fba8cda03 Belgium (BE) | 0937c73e-4918-409f-af6f-557974a0ac60 Hungary (HU) | 9d04a931-95ce-4982-9a87-a18ef7952af4 Germany (DE) | da5c651f-ad6f-4830-9838-75307a3e41c3 Denmark (DK) | f08a6ac8-4d07-4f5c-898a-f2679fcfce7a Croatia (HR) | e5f5944f-30ce-44b8-8ebb-05cf2225445f Germany (DE) | d823427b-c5b3-4acc-a2e1-44f9e431cdb6 Sweden (SE) | 4d1f1b0b-a1a8-4b10-9353-82985f57e486 Czech Republic (CZ) | a436ebcb-6858-4e91-a544-76295a66beaf Bulgaria (BG) | 3fd23387-967b-4388-9761-8955fca8bce3 Poland (PL) | b2427607-c00a-4329-a107-c14d150320d3 Poland (PL) | e989eb56-ff47-4239-98f3-b36f796831b4 Germany (DE) | 25352a15-a89c-429c-a0a8-806c4e439c39 Germany (DE) | afde0b89-a30b-47b7-b23b-09c6143ea6e5 Portugal (PT) | 8aef2b00-f063-4756-acbb-46e9971a295e Belgium (BE) | a068cb1a-c512-4bf6-ab3d-0e491507784c France (FR) | 5077a1bc-4385-4ba3-89b5-eb0fb8bc9d14 Greece (GR) | 1975c665-8935-4c58-9838-7105c5430cb6 Poland (PL) | cd037e7d-ddcc-43fa-8ce7-dc0c1d3037b1 Hungary (HU) | e72ba110-0eeb-4867-b68e-d16ad988f01a Estonia (EE) | 0a5f6690-c8b4-422f-97b4-25e1f8ce2658 Finland (FI) | f31b02ea-699e-4aa6-984f-9bc837bf3372 Sweden (SE) | b5909528-8376-4dd7-b35e-9ac49c403ff8 Netherlands (NL) | b3e714ed-4814-4636-ab0d-2826b3fb2859 Norway (NO)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HE3125AFF000XXX
E-Number (Norway)
4379221
EAN
8015644013479
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644013479
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 3p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 10.7 W
Rated Current (In)
125 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1250 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 52.5 kA | (415 V AC) 37.5 kA | (440 V AC) 32.5 kA | (500 V AC) 25 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 52.5 kA | (500 V DC) 3 Poles in Series 52.5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 35 kA | (690 V AC) 10 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
87.5...125 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: 3P fixed front-terminals with bolt connection and 6 N·m tightening torque simplify installation and reduce assembly time in control panels; the result is faster commissioning and fewer field wiring errors in motor control centers and distribution boards. Feature → Setting range of 87.5 to 125 A enables site tuning to protect feeders and transformers without unexpected trips, improving uptime and reducing nuisance outages in critical processes. Feature → Rated current 125 A and rated voltage 690 V ensure compatible protection for medium-power LV networks, enabling reliable MCCs and transformer feeders with consistent protection margins. Feature → Short-circuit current settings up to 1250 A and Ics up to 80 kA across common voltages translate to strong fault protection, lowering the risk of extensive panel damage and equipment downtime. Feature → Energy loss of 10.7 W per pole supports heat management and energy efficiency in compact enclosures, contributing to cooler cabinets and lower cooling costs. Feature → RoHS/REACH compliance, EPD, and recyclability data promote regulatory compliance and sustainable end-of-life handling, aiding procurement teams in audits and green procurement. Feature → Front-terminal design and 3P XT1 lineage offer compatibility with 45.5–80 mm² busbars and M6 screw-driver tools, enabling straightforward retrofits and easier ongoing maintenance in retrofit projects.
Get a Quick Quote for a ABB 1SDA067453R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067453R1?
Enquire Now
FAQs
This device supports front-terminal, bolt connections and is compatible with busbars in the 45.5 to 80 mm² range. Installation uses a recommended 6 N·m tightening torque with an M6 screwdriver, making it suitable for standard low-voltage distribution panels and MCCs.
The unit is rated for 125 A nominal current and 690 V operating voltage, with an 8 kV rated impulse withstand. It provides a 1250 A instantaneous short-circuit setting and up to 80 kA service/ultimate breaking capacity at common voltages, ensuring strong protection for medium-power feeders.
Yes. As part of the SACE Tmax XT family, it is designed for robust protection in motor control centers and transformer feeders, delivering reliable short-circuit protection and easy integration into standard MCC architectures.
The product complies with IEC 60947-2. It carries a CE declaration of conformity and has third-party certifications such as LR and GL. It also aligns with RoHS/REACH requirements and provides environmental data like EPD and recyclability metrics.
Durability includes 8000 electrical and 25000 mechanical cycles, reducing replacement frequency and downtime. Energy loss is 10.7 W per pole, aiding cooling and efficiency. Front-terminal design simplifies inspection and replacements, supporting faster maintenance and lower lifecycle costs.