ABB 1SDA067464R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA067464R1
Manufacturer
ABB
Part number
1SDA067464R1

Quick Summary

ABB 1SDA067464R1 Moulded Case Circuit Breaker provides reliable protection for industrial power distribution in switchgear. Nuisance trips, downtime, and maintenance complexity are common pain points in protection schemes that this device helps address. Key certifications include CE conformity (EC Declaration of Conformity Tmax XT1), IEC 60947-2 compliance, and LR/GL certificates to support global deployment. In practice, this XT1 device integrates with SACE Tmax XT protection schemes to boost system reliability and overall lifecycle cost efficiency.

Product Information

Extended Description

1SDA067464R1 ABB: C.BREAKER TMAX XT1H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 160-1600 A FULLY RATED NEUTRAL
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT1
Environmental Product Declaration - EPD
EPD Tmax XT XT1 (IT) | EPD Tmax XT XT1 (CN)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT1HE4160AFF000XXX
E-Number (Norway)
4379251
EAN
8015644695248
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.58 kg
Package Level 1 EAN
8015644695248
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT1 4p FIXED F
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 15 W
Rated Current (In)
160 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1600 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA | (230 V AC) 80 kA | (240 V AC) 80 kA | (380 V AC) 52.5 kA | (415 V AC) 37.5 kA | (440 V AC) 32.5 kA | (500 V AC) 25 kA | (525 V AC) 17.5 kA | (690 V AC) 5 kA | (250 V DC) 2 Poles in Series 52.5 kA | (500 V DC) 3 Poles in Series 52.5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 35 kA | (690 V AC) 10 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
112...160 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT1
GL Certificate
1SDL000163R0103
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT1 3p-4p fixed front terminals
Mechanical Drawings
XT1 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation instructions XT1
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
The XT1H 160A 4P design features fixed front terminals for reliable, safer connections, enabling faster installation and easier service in cramped switchgear cabinets, reducing wiring errors and improving maintenance efficiency. The thermomagnetic release (TMD) provides fast, selective tripping during overloads, protecting transformers, feeders and motors while minimizing collateral damage. A setting range of 112–160 A offers flexible coordination with existing protection schemes, supporting optimized protection curves and reduced nuisance trips. With a rated voltage of 690 V AC / 500 V DC and Ui of 800 V, it delivers robust insulation for diverse industrial environments. Icu up to 100 kA and Ics up to 80 kA at low voltages ensure strong fault withstand; power loss stays low at 15 W per pole, aiding thermal management. The device’s 4P fixed front-terminal design simplifies mounting and wiring, while a 6 N·m tightening torque and busbar compatibility (45.5–80 mm²) streamline installation and commissioning for motor feeders and distribution panels.

Get a Quick Quote for a ABB 1SDA067464R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067464R1? Enquire Now

FAQs

Choose a front-terminal, fixed 4P configuration to simplify wiring in tight switchgear spaces. Ensure busbar connections use 45.5–80 mm² conductors, torque each terminal to 6 N·m, and leave adequate clearance for thermal dissipation. The unit’s compact XT1 footprint fits standard panel cutouts and allows straightforward retrofits in existing protection schemes.
It is rated for 160 A with 690 V AC / 500 V DC operation, Ui of 800 V, and Icu up to 100 kA across 220–240 V AC, with 5–10 kA at higher voltages. Ics reaches up to 80 kA at low voltages, providing strong short-circuit withstand capabilities for panel protection and transformer feeders.
Yes. The device supports both AC and DC applications and is rated for 50/60 Hz operation, making it suitable for a wide range of industrial power distribution scenarios, including mixed-voltage facilities and data centers.
This model adheres to IEC 60947-2 and carries CE conformity (EC Declaration of Conformity Tmax XT1). Additional certifications include LR and GL, supporting global deployment, while UL and VDE certifications are listed as not required for this variant.
With a thermomagnetic release (TMD) and solid durability ratings, it minimizes nuisance trips and unplanned downtime. Rated electrical durability is up to 8000 cycles, and mechanical durability up to 25000 cycles, while power loss is only 15 W per pole, contributing to lower operating temperatures and longer service life, improving total cost of ownership.