ABB 1SDA067471R1 Accessory - 4P XT4 IEC60947-2

Part Number: 1SDA067471R1
Manufacturer
ABB
Part number
1SDA067471R1

Quick Summary

ABB 1SDA067471R1 Accessory is a four-pole thermomagnetic release for Tmax XT power distribution in industrial control. Engineers often grapple with nuisance trips and complex wiring during maintenance, leading to downtime and reduced productivity. This product aligns with IEC 60947-2 safety standards and supports RoHS, REACH, and TSCA declarations to ease regulatory audits. By pairing with Tmax XT, it delivers reliable protection, simplifies installation, and helps panel builders scale from small machines to larger line configurations, while reducing total cost of ownership.

Product Information

Extended Description

1SDA067471R1 ABB: THERMOMAGNETIC RELEASE FOUR-POLE IN AC-DC TMA R 40 I3=200...400 A XT4
Environmental Product Declaration - EPD
NoDecNee
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
E-Number (Finland)
3641132
E-Number (Norway)
4380209
EAN
8015644013639
Minimum Order Quantity
1 piece
Customs Tariff Number
85389099
Product Net Weight
1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
162 mm
Package Level 1 Height
92 mm
Package Level 1 Depth / Length
100 mm
Package Level 1 Gross Weight
1.1 kg
Package Level 1 EAN
8015644013639
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
Accessories for Tmax XT
Product Name
Accessory
Product Type
Accessory
Suitable For
XT4
Suitable for Product Class
SACE Tmax XT
Configuration Type
Loose or configurable
Current Type
AC/DC
Number of Poles
4P
Order Multiple
1 piece
Rated Current (In)
40 A
Release
TMA
Release Type
TM
Standards
IEC60947-2
Data Sheet, Technical Information
1SDC210100D0205 | 1SDC210099D0205
Declaration of Conformity - CE
Refer to the EU Declaration of the relative Circuit Breaker
Instructions and Manuals
Release assembly XT2-XT4
ETIM 8
EC001023 - Shunt release (for power circuit breaker)
ETIM 9
EC001023 - Shunt release (for power circuit breaker)
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370418
Feature: Four-pole thermomagnetic release (TMA) for Tmax XT, 40 A rating. Business impact: Coordinated protection across all phases reduces the risk of cascading faults and minimizes unplanned downtime. Application: Ideal for four-pole power distribution in manufacturing lines, motor control centers, and machine panels where reliable disconnection is critical. Feature: AC/DC current type with loose or configurable installation. Business impact: Flexible integration with existing XT4 assemblies reduces field wiring time and installation errors. Application: Suitable for XT4 upgrades or new builds in control panels across manufacturing plants. Feature: IEC 60947-2, RoHS, REACH, and CMRT/TSCA compliance. Business impact: Regulatory alignment minimizes compliance risk and streamlines supplier audits; environmental declarations support sustainability reporting. Application: Global production environments and panel builders targeting EU and US markets. Feature: Clear documentation and robust compatibility with Tmax XT accessories. Business impact: Improves lifecycle management and maintenance planning; reduces mis-matching parts and returns. Application: Ideal for upgrade programs and OEM panel builds. Feature: Data sheet references 1SDC210100D0205 and 1SDC210099D0205. Business impact: Ensures quick access to installation and electrical specifications, expediting procurement and commissioning. Application: Engineering design and service documentation for Tmax XT installations.

Get a Quick Quote for a ABB 1SDA067471R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067471R1? Enquire Now

FAQs

To install, confirm XT4 compatibility and 4P configuration, then mount the accessory onto the Tmax XT frame following the referenced XT2-XT4 release instructions. Ensure all wiring complies with IEC 60947-2 and that the AC/DC release coil connections are secure. Verify packaging and EAN details are correct before commissioning to minimize post-install adjustments.
Yes. The accessory is rated for 40 A (I n) in a four-pole configuration and is designed to work with Tmax XT builds requiring a TMA release. This enables coordinated protection across all phases, improving fault handling and maintaining safe, reliable operation in motor control and distribution panels.
The product complies with IEC 60947-2 and carries RoHS and REACH declarations, along with TSCA coverage and CMRT. Environmental and compliance documentation, including related data sheets, EPD context, and DoC references, supports regulatory audits and supplier approvals for global deployments.
Key factors include selecting the four-pole XT4 configuration, using the loose or configurable mounting option, and properly wiring the AC/DC release coil. By adhering to the official assembly instructions (XT2-XT4), maintaining correct torque on connections, and validating with the associated data sheets, you reduce nuisance trips and streamline future maintenance.
Expected ROI stems from reduced nuisance tripping, faster commissioning, and lower maintenance costs due to reliable, scalable protection. The 40 A four-pole TMA release minimizes unplanned downtime in motor control centers, simplifies regulatory compliance, and supports faster panel upgrades, yielding measurable uptime gains and long-term total cost of ownership improvements.