ABB 1SDA067586R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067586R1
Quick Summary
ABB 1SDA067586R1 Moulded Case Circuit Breaker protects industrial power distribution networks against overloads and short circuits. Across plants, nuisance trips and hard-to-access terminals can drive maintenance complexity and downtime. This device aligns with CE conformity under the EC Declaration of Conformity Tmax XT2 and is supported by GL and LR certificates, offering regulatory assurance and supplier confidence. The product belongs to the SACE Tmax XT family, featuring three fixed front-terminal poles for fast wiring and straightforward servicing. Designed for 690 V systems with a 2.5 A nominal current, it also supports RoHS/REACH compliance and an established EPD, enabling greener, compliant panel builds. In practice, it reduces installation time while improving overall panel reliability and lifecycle value.
Product Information
Extended Description
1SDA067586R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 2,5-25 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3002BFF000XXX
E-Number (Norway)
4379283
EAN
8015644014827
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644014827
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.47 W
Rated Current (In)
2.5 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
25 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
1.75...2.5 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Three-pole fixed front terminals enable quick, error-free wiring and safer maintenance in control cabinets, reducing commissioning time and field faults for machine builders. Application: primary power distribution panels and switchgear. Feature → Business Impact → Application: TMD release with a 1.75–2.5 A setting range provides precise overload protection and selective tripping, minimizing downtime and preventing nuisance trips in automated lines. Application: panel protectors in process lines and robotics. Feature → Business Impact → Application: 690 V rated operational voltage with 2.5 A nominal current and 25 A instantaneous setting offers reliable protection for low to medium power circuits, improving system availability in industrial complexes. Application: data centers, packaging lines, and material handling systems. Feature → Business Impact → Application: Front-terminal design and 6 N·m tightening torque simplify installation and reduce risk of loose connections, enhancing long-term reliability. Application: new panel builds and retrofit projects. Feature → Business Impact → Application: Environmental and compliance attributes such as RoHS, REACH declarations and EPD support sustainable manufacturing practices, aiding in regulatory reporting and end-of-life planning. Application: OEMs pursuing green certifications and recyclability targets.
Get a Quick Quote for a ABB 1SDA067586R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067586R1?
Enquire Now
FAQs
The unit is designed for front-terminal mounting with bolt connections and a 6 N·m tightening torque, matching standard ABB SACE Tmax XT installations. It supports 690 V systems and 3P arrangements, making it a straightforward upgrade or retrofit for existing Tmax XT panels without requiring major cabinet adjustments.
Key protection features include a TMD release with a 1.75–2.5 A setting range, a rated current of 2.5 A, and a rated voltage of 690 V. It offers 25 A instantaneous trip and IEC60947-2 compliance, with a rated ultimate breaking capacity suitable for typical industrial distribution while maintaining safe operation in automation environments.
Yes, the product carries RoHS declarations and REACH compliance as part of ABB Sace circuit breakers. It also provides an Environmental Product Declaration (EPD) for Tmax XT XT2, plus recyclability data per EN45555, supporting responsible disposal and sustainability reporting in modern manufacturing.
Plan for front-terminal access and bolt-type terminals with a 6 N·m torque specification. Ensure conductor cross-sections between 32.5 and 100 mm² for main circuit connections, and verify compatibility with 3P front-mounted busbar configurations to maintain reliable conductance and easy maintenance.
By reducing nuisance trips through precise setting ranges, enabling easier wiring with front terminals, and meeting RoHS/EPD requirements, this XT2 device lowers commissioning time, minimizes downtime, and supports longer product lifecycles. The combination of high reliability and efficient installation translates to lower maintenance costs and faster payback in automation projects.