ABB 1SDA067588R1 Moulded Circuit Breaker XT2 protects industrial panels by quickly interrupting fault currents. Engineers often wrestle with nuisance trips, complex wiring, and space constraints in dense control rooms. This device adheres to IEC 60947-2 and carries CE conformity via the EC Declaration of Conformity while aligning with RoHS and REACH requirements, underscoring sustainability and regulatory compliance. Built on the SACE Tmax XT platform, it delivers compact installation, front-terminal access, and reliable thermal-magnetic protection, enabling safer, more maintainable power distribution in manufacturing, processing, and utilities environments. For buyers seeking dependable protection with proven standards, this module combines performance with total cost of ownership advantages and straightforward field serviceability.

Product Information

Extended Description

1SDA067588R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 4-40 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3004AFF000XXX
E-Number (Norway)
4379285
EAN
8015644014841
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644014841
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.47 W
Rated Current (In)
4 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
40 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
2.8...4 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: 3P XT2 molded circuit breaker with front terminals enables rapid wiring and modular upgrades, reducing installation time and on-site risk in control panels and switchboards. This improves commissioning efficiency and minimizes downtime during plant modifications, especially in high-density installations. Feature → Setting range 2.8–4 A and rated current 4 A enables precise, scalable overcurrent protection for small-to-medium loads, reducing nuisance trips and extending equipment life in motor circuits and distribution boards. Feature → Thermomagnetic release (TMD) delivers selectivity and fast fault clearing, improving safety and uptime in critical processes such as extrusion lines or packaging lines where precise protection matters. Feature → Rated voltage 690 V and insulation voltage 1000 V ensures compatibility with modern industrial networks and transformer protection schemes, supporting future-proofing of inland and offshore facilities. Feature → Front connection type and bolt terminals simplify wiring, enable reliable busbar connections (32.5–100 mm²) and secure torque (6 N·m), lowering installation errors and maintenance cost in electrical rooms. Feature → Compact XT2 form factor and weight around 1.1 kg per unit, along with EcoSolutions and EPD data, helps optimize spare parts inventory and sustainability reporting for modern plant operations. Feature → Compliance with IEC 60947-2 and CE ensures regulatory legitimacy and customer confidence for panel builds, especially in healthcare, food & beverage, and automotive suppliers requiring audited protection. Feature → Environmental and material compliance data, including RoHS, REACH, CMRT and TSCA declarations, supports procurement policies focused on responsible sourcing and end-of-life planning. Feature → Availability of EPDs and disassembly instructions supports life-cycle assessments, facilitating waste reduction programs and circular economy initiatives for large OEMs. Application → The combination of 3P configuration, 690 V capability, and front-terminal installation makes this breaker ideal for main feeders, transformer protection, and distribution panels in industrial plants, enabling safer, more efficient protection schemes and streamlined maintenance programs.

Get a Quick Quote for a ABB 1SDA067588R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067588R1? Enquire Now

FAQs

The XT2 3P with front terminals streamlines wiring by enabling straightforward vertical or horizontal mounting and direct busbar connections. With 32.5 to 100 mm² busbar capacity and a 6 N·m tightening torque, it reduces wiring errors and installation time while ensuring reliable, vibration-resistant terminations in compact control cabinets.
Key specs include 4 A rated current, 690 V rated voltage, 1000 V rated insulation voltage, 50/60 Hz compatibility, setting range 2.8–4 A, Ics up to 70–100 kA depending on voltage, and Iu of 160 A. These enable robust protection for low-to-medium power feeders and transformer inputs in typical industrial environments.
Yes. It complies with IEC 60947-2 and bears CE conformity via EC Declaration of Conformity. It also supports RoHS and REACH declarations, is associated with EPD data for environmental assessment, and provides end-of-life information and disassembly instructions for sustainable disposal.
Ideal for main feeders, transformer protection, and distribution panels in manufacturing, process lines, and energy facilities. Its 3P XT2 configuration, front-terminal access, and tight integration with SACE Tmax XT enable reliable protection with quick maintenance, reduced downtime, and scalable protection for evolving plant loads.
Plan for periodic torque checks (6 N·m), verify front-terminal integrity, and monitor operating temperature to maintain stable performance. The product offers disassembly guidelines and an established Release (TMD) and setting range maintenance. Availability of data sheets and ECO-compliant lifecycle data aids in budgeting and lifecycle planning.