ABB 1SDA067590R1 MCCB - XT2H 690V 6.3A, IEC60947-2
Part Number: 1SDA067590R1
Quick Summary
ABB 1SDA067590R1 MCCB is designed to protect low-voltage distribution networks with three fixed front-terminal poles. It helps engineers prevent arc faults and unplanned downtime by providing reliable overcurrent protection with a thermomagnetic release (TMD). In practice, the XT2H series delivers rapid tripping at adjustable settings, and supports 690 V AC/500 V DC applications, making it suitable for machine, panel, and generator protection. This device aligns with IEC 60947-2 and CE conformity, and carries LR certificate status to support global deployments. By centralizing protection, diagnostics, and maintenance tasks, it reduces installation complexity and total cost of ownership while supporting sustainability and compliance programs across multinational sites.
Product Information
Extended Description
1SDA067590R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 6,3-63 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3006AFF000XXX
E-Number (Norway)
4379287
EAN
8015644014865
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644014865
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.33 W
Rated Current (In)
6.3 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
63 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
4.41...6.3 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The XT2H 3P fixed front-terminal design enhances reliability and simplifies panel layout, reducing wiring errors and assembly time in electrical enclosures. This translates to faster commissioning, lower labor costs, and improved overall equipment effectiveness in manufacturing lines and critical infrastructure. Feature → Business Impact → Application: The 4.41 to 6.3 A setting range enables precise protection for small-to-moderate loads, enabling engineers to tailor protection curves to motor starters, feeders, and distribution blocks, minimizing nuisance trips while preserving uptime on packaging machines and CNC cells. Feature → Business Impact → Application: Rated 690 V AC / 500 V DC operation and 1000 V Ui rating ensure safe integration with mixed-voltage systems, supporting cross-site use in data centers, process lines, and automotive assembly. Feature → Business Impact → Application: Thermomagnetic release (TMD) provides fast, predictable trip performance under short-circuit conditions, reducing fault severity and equipment damage in power distribution boards and machine controls. Feature → Business Impact → Application: Front-terminal, bolt-type connections with a 6 N·m tightening torque simplify installation and maintenance, enabling robust, vibration-resistant connections in harsh industrial environments. Feature → Business Impact → Application: Power loss of 3.33 W per pole improves energy accounting in panel design and helps meet energy-efficiency targets for modern factories. Feature → Business Impact → Application: Compliance with IEC 60947-2 and CE declarations supports regulatory approvals for global deployments, while LR certificate backing enhances vendor qualification for utilities and OEMs.
Get a Quick Quote for a ABB 1SDA067590R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067590R1?
Enquire Now
FAQs
This three-pole MCCB with front-terminal connections is designed for low-voltage distribution panels and machine controls. It supports busbar connections from 32.5 to 100 mm² and is suitable for 690 V AC and 500 V DC systems, making it ideal for industrial automation cabinets, process lines, and packaging machinery.
Key specs include a rated current of 6.3 A, an adjustable setting range from 4.41 to 6.3 A, a rated operational voltage of 690 V AC / 500 V DC, and Ui of 1000 V. It offers short-circuit capabilities up to 100 kA (Ics) with higher instantaneous values (Icu) depending on voltage, and a release type TMD with TM characteristics.
Yes. The three-pole XT2H MCCB with front-terminal connections is well-suited for motor feeders, distribution panels, and machine protection in manufacturing and process environments. Its setting range, fast tripping, and compact footprint help minimize wiring complexity while delivering reliable protection for critical loads.
This device complies with IEC 60947-2 and carries CE conformity (EC DoC Tmax XT2). It also holds LR certification for Tmax XT series and GL certificate documentation, supporting regulatory acceptance and global deployment across sites with varied requirements.
The MCCB’s static front-terminal design and robust release mechanism reduce maintenance time during inspections. With reliable protection reducing fault-induced downtime, energy efficiency in panel design improves, and the compact form factor helps maximize enclosure space, contributing to lower total cost of ownership in converters, conveyors, and automated lines.