ABB 1SDA067594R1 Moulded Case Circuit Breaker - XT2H TMD
Part Number: 1SDA067594R1
Quick Summary
ABB 1SDA067594R1 is a Tmax XT2H molded case circuit breaker for reliable power distribution protection. Engineers often struggle with limited front-terminal access, wiring complexity, and downtime during maintenance. This variant carries IEC60947-2 conformity, CE Declaration of Conformity, and LR/GL certificates to support global approvals and traceability. With front-terminal installation, a fixed 3-pole configuration, and a defined 16 A setting range, commissioning is efficient and repeatable. EcoSolutions features, recyclability data, and end-of-life instructions help reduce lifecycle costs while supporting sustainability targets. The design also supports straightforward mounting on standard busbars and a 6 N·m tightening torque, delivering predictable performance in industrial panels.
Product Information
Extended Description
1SDA067594R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 16-300 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3016AFF000XXX
E-Number (Norway)
4379291
EAN
8015644014902
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.658 kg
Package Level 1 EAN
8015644014902
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.33 W
Rated Current (In)
16 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
300 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
11.2...16 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal fixed 3P configuration enables faster wiring, easier panel assembly, and reduced maintenance downtime. Business Impact: Improves installation throughput and reduces labor costs on new builds or retrofits. Application: Main distribution boards and machine control panels where space is tight and wiring clarity is essential. Feature: TMD release provides precise, selective tripping, improving system reliability and fault isolation. Business Impact: Minimizes unplanned outages and protects downstream equipment, lowering downtime costs. Application: Industrial power distribution where coordinated protection is critical. Feature: 16 A rated current with a broad setting range (11.2–16 A) and 690 V operational voltage. Business Impact: Offers targeted protection for small-to-medium loads while accommodating future load growth. Application: Control circuits, small drives, and feeder protection in process lines. Feature: High short-circuit capability (Ics up to 100 kA) and 8 kV impulse withstand. Business Impact: Enhanced system safety in harsh fault conditions, reducing risk of collateral damage. Application: Medium-voltage LV panel protection for transformers and MCCs. Feature: ECO/Sustainability data including EPD, RoHS/REACH declarations, and 55.70% recyclability per EN45555. Business Impact: Supports sustainability reporting, regulatory compliance, and end-of-life planning. Application: Green initiatives in industrial facilities and regulated industries. Feature: Robust mechanical specs — 6 N·m tightening torque, front-terminal bolt connections, and 32.5–100 mm² busbar compatibility. Business Impact: Faster, repeatable installation with durable mechanicals reducing torque-related failures. Application: New installations and retrofits in standard switchgear housings.
Get a Quick Quote for a ABB 1SDA067594R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067594R1?
Enquire Now
FAQs
Install using front-terminal connections designed for bolt-type terminals. Use busbars in the 32.5–100 mm² range, tighten bolts to 6 N·m, and secure with an M6 screwdriver. This arrangement simplifies wiring, speeds up commissioning, and ensures consistent electrical performance in MCCs or switchgear.
Rated current is 16 A with a setting range of 11.2–16 A. Rated operational voltage is 690 V, and the device provides a short-circuit current capacity up to 100 kA (Icu) depending on voltage. These specs enable reliable protection for small-to-medium industrial feeders while accommodating transient faults.
Yes. The 3P fixed XT2H design with front terminals and TM release is well-suited for transformer and MCC protection in process lines, offering fast tripping, high fault current handling, and compliant installation per IEC 60947-2. It also supports compact layouts due to its front-access wiring and standardized busbar connections.
This variant carries IEC 60947-2 conformity, CE Declaration of Conformity, and LR/GL certificates. It also provides REACH and RoHS declarations and an Environmental Product Declaration (EPD) for Tmax XT XT2 TM, plus recyclability data per EN45555 to support sustainability reporting.
With a modular front-terminal design, defined tightening torque, and documented end-of-life instructions, maintenance is straightforward and predictable. The EcoSolutions data, including recyclability and packaging guidance, helps reduce waste and simplify regulator-compliant disposal, contributing to lower total cost of ownership over the equipment lifecycle.