ABB XT2H 160 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067595R1
Quick Summary
ABB XT2H 160 molded case circuit breaker provides fixed three-pole protection for low-voltage distribution in industrial power panels. Designers struggle with limited space, complex wiring, and mounting/maintenance while meeting evolving safety and environmental standards. This device complies with IEC60947-2 and CE, with LR and GL certifications confirming long-term reliability. Combined with front-terminal wiring and a 14–20 A setting range, it reduces panel time and maintenance costs. With a 3-pole design, 690 V rating, and high availability of Ics/Icu ratings, XT2H 160 supports scalable protection for growing, modular plants. Its compatibility with standard busbars and front-terminal wiring simplifies retrofits and new builds, reducing commissioning time.
Product Information
Extended Description
1SDA067595R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 20-300 A
Country of Origin
China (CN)
Lead Time
21 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3020AFF000XXX
E-Number (Norway)
4379292
EAN
8015644014919
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.663 kg
Package Level 1 EAN
8015644014919
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.62 W
Rated Current (In)
20 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
300 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
14...20 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The XT2H 160 is a fixed, 3-pole molded case circuit breaker with front terminals and a TM release (TMD). Benefit: enables fast, secure wiring and reliable protection in compact panels, reducing installation time and risk of loose connections. Application: transformer feeders and distribution boards in industrial facilities. Feature → Business Impact → Application: The device offers a selectable setting range of 14–20 A, enabling precise coordination and selective tripping. Benefit: improves protection accuracy and reduces unwanted outages, lowering downtime costs. Application: motor control centers and critical load feeders. Feature → Business Impact → Application: Rated operational voltage of 690 V AC / 500 V DC and 20 A rated current deliver versatility across environments. Benefit: supports both AC distribution and DC interfaces, expanding compatibility with modern drives and transformers. Application: mixed-voltage industrial installations. Feature → Business Impact → Application: High fault-current capability (Ics up to 100 kA at lower voltages, and 70–100 kA Icu at higher voltages) ensures robust short-circuit protection. Benefit: enhances system resilience and protects equipment from severe faults. Application: power distribution panels and transformer protection schemes. Feature → Business Impact → Application: Front terminal and bolt-type connections with a tightening torque of 6 N·m. Benefit: provides durable, vibration-resistant connections and straightforward maintenance. Application: retrofit projects and new builds with standard busbar systems. Feature → Business Impact → Application: Compliance with IEC60947-2 and CE declarations, plus LR/GL certificates. Benefit: simplifies regulatory approvals and vendor qualification. Application: utility substations and industrial plants requiring proven standards. Feature → Business Impact → Application: EcoSolutions integration and End-of-Life disassembly guidance. Benefit: supports sustainable design and easier recycling flows. Application: environmentally conscious panel builds and fleet upgrades.
Get a Quick Quote for a ABB 1SDA067595R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067595R1?
Enquire Now
FAQs
The XT2H 160 uses front terminals with bolt connections designed for 32.5–100 mm² busbars. Installers should tighten to 6 N·m and verify alignment with standard DIN rail or panel mounting arrangements. Ensure clearances meet enclosure requirements and that the device is positioned for accessible front wiring to simplify maintenance and future upgrades.
At 220–240 V AC, the breaking capacity Ics/Icu is up to 100 kA, while at higher voltages such as 380–440 V AC it reduces to 70–65 kA, and at 690 V AC it remains around 15 kA. For DC configurations (250–500 V), ratings vary with pole count, but the device supports robust protection with a 3P arrangement and modular protection schemes.
Yes. The XT2H 160 is designed as a fixed 3P MCB with a front-terminal configuration suitable for transformer feeders. It provides reliable overcurrent protection, adjustable trip setting (14–20 A), and high short-circuit capability, which helps protect transformer windings and reduce fault propagation in distribution networks.
The XT2H 160 complies with IEC 60947-2 and carries a CE declaration. It also has LR and GL certificates, reflecting independent assurance of performance and safety. UL and VDE certifications are listed as not required for this specific product variant, simplifying global sourcing for many projects.
The device features strong mechanical durability and electrical durability, with 25,000 mechanical cycles and up to 8,000 electrical cycles per hour under typical conditions. Front-terminal design and standardized torque ease wiring checks, while listed compatibility with standard panels reduces spare parts and commissioning time, improving total cost of ownership over the equipment lifecycle.