ABB 1SDA067596R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067596R1
Quick Summary
ABB 1SDA067596R1 Moulded Case Circuit Breaker protects electrical distribution in industrial automation and machinery control. Engineers wrestle with downtime from nuisance trips and mismatched protection schemes that slow startups and spike service costs. This XT2H device complies with IEC 60947-2, carries CE conformity, and holds LR certificate validation for global quality. With front-terminal wiring, configurable protection (17.5–25 A), and a robust 3P platform, it reduces commissioning time and simplifies maintenance. Used within SACE Tmax XT and ABB EcoSolutions programs, it delivers consistent performance, reliable tripping, and long-term cost efficiency for panel builders and OEMs.
Product Information
Extended Description
1SDA067596R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 25-300 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
cfc84dde-e61a-4e38-b07f-5da4036ea9a4 Italy (IT)
Simplified SCIP
60f3a5ce-a473-4456-911e-ac0a2deb4152 Germany (DE) | 1b2e7963-dfa1-45d9-8b2a-1b6c5172378c Norway (NO) | 588d33f0-5dfd-4182-b24c-36b94e148703 Finland (FI) | 0e17691f-b006-45f2-be24-b655b0b8b097 Netherlands (NL) | b63bc7d2-c6c0-49d3-8715-65f45ea937b8 Germany (DE) | 8c45bec7-2fcc-414a-bdd3-dcde1acdd39e Denmark (DK) | 943b1b2a-c881-4828-ae9a-22285d4da212 Netherlands (NL) | ec4c3592-cc19-486b-8a7e-361979719560 Netherlands (NL) | 2b42ea61-971f-4447-815c-868e808a63ba Estonia (EE) | a64fd534-cdf4-4cbd-90c7-a143c153246b Greece (GR) | 3c0b8a52-0cae-4561-a3a3-7d51b13a9475 Portugal (PT) | e5352635-40ab-4bf9-a257-998d8f2d269e Germany (DE) | 7386e9a4-136b-42a6-be67-482534d5c84b Croatia (HR) | 3d07411e-b413-40da-9418-b392c93f18ed Czech Republic (CZ) | 371c7095-86b9-4941-b118-3f9133d596ff Poland (PL) | 0ff16924-d336-4759-a47e-afc804c32099 Germany (DE) | 76299180-5c14-4f42-b82b-73c785ad9452 Germany (DE) | ef2cfb62-d9aa-4d30-92d2-589ab8a12a7e France (FR) | e8206767-1d0c-483e-96b0-8a65ccf203ea Netherlands (NL) | e1342d0e-8629-4bca-bd3d-0380a997960c Spain (ES) | 3044fef1-e5d7-4162-b7bf-6a52a29f8b38 Netherlands (NL) | 3f0c10fe-2ed4-4969-86dc-272c9282ea75 Bulgaria (BG) | d742ac5a-846e-4722-9020-c02906324ba3 Sweden (SE) | fc541581-da0a-4833-877d-70aee274cfc8 Poland (PL) | 64835302-4bcd-4d88-8e7a-cf1fc265821c France (FR) | 355b4542-96dd-4173-b98c-0dfdd78d83d4 Sweden (SE) | bcda9fcf-6239-4554-b97a-c77ffb6efa4d Poland (PL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3025AFF000XXX
E-Number (Finland)
3638600
E-Number (Norway)
4379293
EAN
8015644014926
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644014926
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2 W
Rated Current (In)
25 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
300 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
17.5...25 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal design and fixed XT2H construction streamline installation and reduce wiring errors, delivering a faster panel build and more reliable terminations. This translates into measurable labor savings and fewer post-installation faults in harsh industrial environments. Setting range of 17.5 to 25 A provides precise coordination with downstream devices, minimizing nuisance trips while preserving selective protection. In practice, electricians can tailor protection to motor loads and transformers, improving uptime and reducing warranty calls. High interruption rating with Icu up to 100 kA at low voltages and up to 70 kA at higher voltages ensures safe disconnection under fault conditions across a broad application envelope, including 230–240 V and 690 V systems. Durability metrics—8,000 electrical operations and 25,000 mechanical cycles—translate into extended service life in active panels. Coupled with front-terminal wiring and 6 N·m tightening torque, installation remains robust during vibration and thermal cycling. Sustainability and compliance support ABB EcoSolutions goals with EPDs, recyclability of 55.70%, RoHS compliance, and disassembly instructions, enabling future upgrades within the SACE Tmax XT family while maintaining regulatory alignment.
Get a Quick Quote for a ABB 1SDA067596R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067596R1?
Enquire Now
FAQs
This device uses front-terminal connections for the main circuit, simplifying wiring and verification during panel assembly. It supports busbar connections in the 32.5 to 100 mm² range and requires a tightening torque of 6 N·m, helping maintain a secure, vibration-resistant termination and faster commissioning in control panels.
The MCCB is rated for 25 A and 690 V with an insulation voltage of 1000 V. It offers an adjustable setting range from 17.5 to 25 A, operates under AC/DC, and provides robust interruption capabilities with Ics up to 100 kA at 220–240 V, 70 kA at 380–500 V, and Icu up to 100 kA for low-voltage configurations, supporting reliable protection in transformer and motor circuits.
The product adheres to IEC 60947-2, with CE Declaration of Conformity and LR certificate validation. Additional quality attestations include GL certification, reflecting broad international compliance and suitability for global panel builds in line with ABB EcoSolutions expectations.
Yes. The XT2 device aligns with ABB EcoSolutions by offering recyclability information (55.70%), EPDs for Tmax XT XT2 TM, and disassembly instructions to support end-of-life planning and resource loop strategies within sustainable electrical protection designs.
Expect 8,000 electrical operations and 25,000 mechanical cycles, indicating durable performance in demanding environments. The front-terminal design eases maintenance and future upgrades, while the compact 3P format supports reliable protection without excessive panel footprint.