ABB 1SDA067599R1 Moulded Case Breaker is a three-pole protection device designed for reliable overcurrent protection in industrial power circuits. This model addresses common wiring and accessibility pain points by offering front-terminal connections for quicker, safer installation and servicing. It complies with IEC 60947-2 and features a CE Declaration of Conformity as well as LR and GL certifications for added assurance in critical environments. In addition, ABB EcoSolutions data highlights recyclability and end-of-life considerations, supporting sustainability goals. By pairing compact dimensions with robust electrical ratings, this breaker delivers business value through reduced downtime, easier maintenance, and improved protection for transformers, switchgear, and distribution boards.

Product Information

Extended Description

1SDA067599R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 50 I3=250...500 A
Country of Origin
China (CN)
Lead Time
21 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3050BFF000XXX
E-Number (Finland)
3602497
E-Number (Norway)
4379296
EAN
8015644014957
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.66 kg
Package Level 1 EAN
8015644014957
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.09 W
Rated Current (In)
50 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
300…500 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front terminals and fixed 3P design enable straightforward wiring and dependable accessibility during installation and maintenance. Business Impact: Reduces wiring errors and installation time, delivering measurable site productivity gains. Application: Ideal for compact switchgear and panel boards at 690 V AC systems. Feature: Thermal-magnetic release (TMA) with setting range 35…50 A provides precise protection. Business Impact: Prevents nuisance tripping while ensuring fast isolation during fault events, lowering maintenance costs. Application: Power distribution and transformer protection in industrial plants. Feature: Rated current 50 A and rated voltage 690 V with Uimp 8 kV and Ics up to 100 kA across selected voltages. Business Impact: High fault current resilience and safety margin for critical loads. Application: Protection of motor feeders and distribution feeders in data centers and manufacturing lines. Feature: Front connection type with bolt terminals and 6 N·m tightening torque simplifies commissioning. Business Impact: Faster site wiring and secure terminations, reducing torque-related faults. Application: New installations and retrofits in existing MCCs. Feature: Busbar connection 32.5…100 mm² supports common industrial busbar configurations. Business Impact: Flexible, modular integration with standard busbar systems, reducing parts inventory. Application: Panel assembly and cabinet fit-ups. Feature: ABB EcoSolutions and environmental data including 55.70% recyclability per EN45555 support sustainability objectives. Business Impact: Lower environmental footprint and easier compliance with green procurement policies. Application: Packaging, lifecycle management, and end-of-life planning. Feature: Comprehensive documentation and disassembly guidance for end-of-life processes. Business Impact: Facilitates safe and efficient recycling, reducing total lifecycle costs. Application: Facility upgrades and asset disposition projects.

Get a Quick Quote for a ABB 1SDA067599R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067599R1? Enquire Now

FAQs

This model features front terminals with bolt connections and a 6 N·m tightening torque. Use busbars 32.5–100 mm² and ensure panel cutouts match the 90 mm width, 130 mm height, and 82.5 mm depth. Verify tilt-free mounting in standard MCC enclosures and secure with appropriate hardware for vibration-prone environments.
Rated current is 50 A with a rated voltage of 690 V. Rated impulse withstand voltage is 8 kV. Short-circuit protection includes Ics up to 100 kA depending on voltage, and Icu up to 70–100 kA across applicable voltage ranges. Setting range is 35–50 A, and the device supports AC/DC operation.
Yes. It carries a CE Declaration of Conformity for Tmax XT2 products and adheres to IEC 60947-2. Certifications include LR and GL where applicable, with ABB EcoSolutions data supporting environmental compliance and end-of-life guidance.
Origin is China, with a stated lead time of 21 days. It is not marked as made-to-order, and the product is currently listed as inactive in sales status, which may affect immediate availability but does not alter technical compatibility or performance when procured.
ABB provides an Environmental Product Declaration and End-of-Life guidance, including disassembly instructions and a recyclability rate of 55.70% per EN45555. The product aligns with ABB EcoSolutions practices, supporting sustainable disposal and resource recovery at end-of-life.