ABB 1SDA067602R1 Moulded Case Breaker - XT2H IEC60947-2
Part Number: 1SDA067602R1
Quick Summary
ABB 1SDA067602R1 is a fixed three-pole MCCB for protecting motor and power distribution circuits in industrial plants. It helps prevent cascading faults and unplanned downtime by fast fault isolation and reliable overcurrent protection. The device carries IEC 60947-2 compliance with a CE Declaration of Conformity and recognized GL and LR certification marks. With an adjustable I_i of 500–1000 A, 70–100 A setting range, and front-terminal design, it integrates smoothly into ABB SACE Tmax XT protection schemes. This combination supports scalable protection for panels in manufacturing, process industries, and power distribution, while aligning with sustainability programs via RoHS and EPD.
Product Information
Extended Description
1SDA067602R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 100 I3=500...1000 A
Country of Origin
China (CN)
Lead Time
21 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3100BFF000XXX
E-Number (Finland)
3638174
E-Number (Norway)
4379299
EAN
8015644014988
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.64 kg
Package Level 1 EAN
8015644014988
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 8.08 W
Rated Current (In)
100 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
500…1000 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
70...100 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application. Fixed three-pole XT2H with front-terminal connection streamlines panel wiring, reducing installation time and minimizing torque issues in dense switchgear. This translates to faster commissioning and fewer field wiring errors, particularly in compact control panels and distribution boards where space is at a premium and reliability is critical. Application: motor control centers and process line panels that require robust, space-efficient protection. Feature → Business Impact → Application. Thermomagnetic release TMA provides selective tripping on overload and short-circuit, improving uptime and reducing collateral damage to downstream equipment. This supports predictable maintenance cycles and minimizes unplanned downtime in continuous operation facilities such as assembly lines and packaging halls. Application: high-demand manufacturing lines needing reliable fault isolation. Feature → Business Impact → Application. Rated voltage of 690 V AC (1000 V insulation) enables protection across common industrial feeders, increasing system flexibility and reducing the need for multiple device types. Application: power distribution feeders inindustrial plants, HVAC suites, and processing lines. Feature → Business Impact → Application. I_i range 500–1000 A with a 70–100 A setting range allows precise coordination for transformer and motor protection, delivering tailored protection for varying load profiles and improving selectivity in shared busbar systems. Application: transformer protection and motor feeders in mixed-load panels. Feature → Business Impact → Application. Front-terminal, bolt connection with a tightening torque of 6 N·m and busbar compatibility (32.5–100 mm²) simplify installation and ensure secure, vibration-resistant connections. Application: new panel builds or retrofit projects where quick, reliable terminations are essential. Feature → Business Impact → Application. Environmental and compliance features include RoHS and EPD disclosures, along with end-of-life disassembling instructions and recycling considerations. This supports sustainability goals, regulatory compliance, and easier lifecycle management across industrial facilities. Application: corporate sustainability programs and compliant decommissioning of legacy panels.
Get a Quick Quote for a ABB 1SDA067602R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067602R1?
Enquire Now
FAQs
Key specs include 690 V rated voltage (insulation to 1000 V), 100 A nominal current (In), instantaneous setting 500–1000 A (Ii), adjustable current setting 70–100 A, 3 poles, front-terminal bolt connections, 6 N·m tightening torque, and 50/60 Hz operation. It supports breakers in ABB SACE Tmax XT families and adheres to IEC 60947-2.
The XT2H model provides a setting range of 70–100 A for the rated current coordination, with an adjustable instantaneous current Ik of 500–1000 A. Use the manufacturer’s installation instructions to access the setting dial, ensure the circuit is de-energized, and verify the tripping characteristics with a calibrated test source after adjustment.
This MCCB uses front-terminal, bolt-type connections designed for secure busbar mounting. It accommodates busbar cross-sections from 32.5 to 100 mm² and requires a tightening torque of 6 N·m. The front-terminal design simplifies wiring in compact switchgear and control panels, enabling easier maintenance and faster installation.
The XT2H 3P XT2 complies with IEC 60947-2 and carries a CE Declaration of Conformity. It also has GL and LR certificates, along with environmental declarations (EPD, RoHS) and material compliance (REACH, CMRT, TSCA). These certifications support regulatory compliance, traceability, and sustainability reporting in industrial projects.
The XT2H delivers reliable fault isolation, customizable protection for motor loads, and straightforward installation in front-terminal panels. This reduces downtime, improves protection coordination, and supports compliance with international standards, contributing to lower total cost of ownership and improved panel reliability in manufacturing and process environments.