ABB XT2H 160 TMA 3P Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067604R1
Quick Summary
ABB XT2H 160 TMA 3P Moulded Case Circuit Breaker is designed to protect power distribution panels and transformer feeders with reliable, front-terminal accessibility. This model helps mitigate nuisance trips in demanding environments by using a thermomagnetic release (TMA) for precise overcurrent protection. It carries CE conformity via the EC Declaration of Conformity and is supported by globally recognized certifications such as GL and LR, enabling broader deployment across international sites. With a rated current of 160 A and a setting range of 112–160 A, it delivers scalable protection while maintaining compact plug-in installation. For system integrators, this means easier commissioning, consistent safety margins, and reduced maintenance overhead in industrial electrical distributions.
Product Information
Extended Description
1SDA067604R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 160 I3=800...1600 A
Country of Origin
China (CN)
Lead Time
21 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3160BFF000XXX
E-Number (Finland)
3638054
E-Number (Norway)
4379301
EAN
8015644015008
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.659 kg
Package Level 1 EAN
8015644015008
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 16.15 W
Rated Current (In)
160 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
800…1600 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
112...160 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Front terminals and fixed three-pole design enable quick, safe installation and fast replacement in crowded switchgear, reducing downtime and project labor costs on new builds or refurbishments. This configuration supports reliable busbar connections (32.5–100 mm²) and minimizes wiring errors, improving panel reliability in data centers and manufacturing lines. Feature → Business Impact → Application: Thermomagnetic release (TMA) delivers selective protection with fast trip characteristics, lowering the risk of cascading faults and protecting critical loads such as motors and transformers in machine rooms and process lines. Feature → Business Impact → Application: 690 V rated operational voltage and 160 A nominal current align with typical medium-voltage low-voltage boundary protection, enabling compact main-distribution use in MCCs and transformer feeder panels. Feature → Business Impact → Application: Large Ics/Icu ratings provide high fault-current withstand, reducing unplanned outages and enabling safe service restoration in high-demand facilities. Feature → Business Impact → Application: Compliance with IEC60947-2 and availability of ECO solutions like EPD and End of Life disassembly instructions support corporate sustainability goals while maintaining industry-standard performance. Feature → Business Impact → Application: Lightweight, compact dimensions (90 mm x 130 mm x 82.5 mm) and a per-pole power loss of 16.15 W enable cleaner cabinet layouts and improved thermal management in compact switchgear housings.
Get a Quick Quote for a ABB 1SDA067604R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067604R1?
Enquire Now
FAQs
Yes. XT2H 160 TMA 3P supports front-terminal connections and is compatible with busbars in the 32.5–100 mm² range. When wiring, ensure a clean, tight connection to the front terminals (Bolt type) with the recommended tightening torque of 6 N·m to maintain optimal current paths and thermal performance.
Key ratings include a rated current of 160 A, rated voltage of 690 V, and a setting range of 112–160 A. It also provides a rated impulse withstand voltage of 8 kV and a rated service short-circuit breaking capacity up to 100 kA (depending on voltage). These specifications support reliable protection for feeders and MCCs.
Ideal for power distribution panels, transformer feeders, and motor control centers where reliable overcurrent protection is required. Its front-terminal design facilitates quick maintenance, while the high Ics/Icu ratings protect critical loads from short-circuit surges without unnecessary tripping.
This breaker conforms to IEC60947-2, with a CE declaration of conformity. It also lists GL and LR certificates, supporting international use and safety compliance across European and global facilities.
The fixed front-terminal design, clear wiring diagrams, and robust thermomagnetic release reduce commissioning time and maintenance cycles. With a compact form factor and reliable trip performance, you can expect lower downtime, fewer fault investigations, and a favorable return on investment in panel upgrades and new installations.