ABB 1SDA067615R1 Moulded Case Breaker - IEC60947-2

Part Number: 1SDA067615R1
Manufacturer
ABB
Part number
1SDA067615R1

Quick Summary

ABB 1SDA067615R1 Moulded Case Breaker protects distribution panels by interrupting fault currents in low-voltage networks. Users often confront compatibility gaps and long lead times when sourcing TMD-released, four-pole front-terminal breakers for modern switchgear upgrades. This device complies with IEC 60947-2 and CE declarations, supported by environmental and material compliance data such as RoHS and REACH declarations, plus an EPD for Tmax XT families. By standardizing on the XT2 platform, procurement teams can reduce part variety while improving serviceability. The product also aligns with ABB EcoSolutions programs for responsible end-of-life handling and waste reduction, delivering a compelling combination of reliability, safety, and total cost of ownership reduction for panel builders and integrators.

Product Information

Extended Description

1SDA067615R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 16-300 A
Country of Origin
China (CN)
Lead Time
28 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4016AFF000XXX
E-Number (Norway)
4379608
EAN
8015644015114
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.55 kg
Package Level 1 EAN
8015644015114
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.33 W
Rated Current (In)
16 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
300 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
11.2...16 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal, four-pole XT2H design simplifies installation and maintenance, reducing commissioning time and potential wiring faults in dense switchgear environments. Feature → Business Impact → Application: The fixed front terminals paired with a 6 N·m tightening torque ensure repeatable, secure connections for 32.5–100 mm² busbars, cutting field troubleshooting time and improving reliability in MCCs and distribution cabinets. Feature → Business Impact → Application: 16 A rated current with a 11.2–16 A setting range (Ii = 300 A instantaneous) enables precise protection coordination for transformers and feeders while minimizing nuisance trips. Feature → Business Impact → Application: Electrical durability of 8000 cycles and mechanical durability of 25000 cycles translates to lower maintenance costs and longer service intervals in high-cycle environments such as data centers and manufacturing lines. Feature → Business Impact → Application: IEC60947-2 compliance, RoHS/REACH declarations, and an available EPD support regulatory alignment and sustainable procurement for global projects. Feature → Business Impact → Application: 120 mm width, 130 mm height, 82.5 mm depth and 1.45 kg weight provide a compact footprint for space-constrained panels, enabling quick replacement in retrofit projects and new builds alike.

Get a Quick Quote for a ABB 1SDA067615R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067615R1? Enquire Now

FAQs

Yes. It uses front terminals with busbar connections from 32.5 to 100 mm². The unit is a four-pole XT2 design requiring a 6 N·m tightening torque, fitting typical MCCs and compact switchgear panels.
Rated current is 16 A with a setting range of 11.2–16 A. It offers 690 V rated voltage, 8 kV impulse withstand, and a 300 A instantaneous setting (Ii). Icu/Ics values vary by voltage but support high short-circuit protection in industrial apps.
Ideal for low-voltage distribution, MCCs, transformer feeders, and main protection in panel boards. Its front-terminal design and robust IEC 60947-2 compliance make it a reliable choice for industrial distribution and retrofit projects.
IEC 60947-2 is the primary standard, with CE conformity declared. RoHS/REACH declarations and an available EPD for Tmax XT families further support environmental and regulatory requirements.
Electrical durability is rated at 8000 cycles and mechanical durability at 25,000 cycles, reducing maintenance. Warranty terms reference a standard policy that may require product returns for warranty validation; refer to the supplier’s terms and ABB EcoSolutions guidance for recycling and end-of-life options.