ABB 1SDA067620R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA067620R1
Manufacturer
ABB
Part number
1SDA067620R1

Quick Summary

The Moulded Case Circuit Breaker 1SDA067620R1 provides reliable overcurrent protection for low-voltage power distribution. Engineers often face space constraints, complex wiring, and downtime during maintenance; this ABB solution addresses those challenges with front-terminal access and compact dimensions. It complies with IEC 60947-2, carries a CE declaration of conformity, and holds an LR certificate, underscoring safety and long-term reliability. When paired with the SACE Tmax XT family, it enables scalable protection strategies, easier installation, and predictable lifecycle costs. ABB EcoSolutions further enhances sustainability through disassembly instructions and an established recyclability profile.

Product Information

Extended Description

1SDA067620R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 50 I3=250...500 A
Country of Origin
China (CN)
Lead Time
28 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4050BFF000XXX
E-Number (Norway)
4379613
EAN
8015644015169
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.55 kg
Package Level 1 EAN
8015644015169
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.09 W
Rated Current (In)
50 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
300…500 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The 4-pole XT2 design with front terminals simplifies wiring and panel layout, reducing install time and improving fault isolation in motor control centers and transformer protection scenarios. Application: Use in compact switchgear where space is at a premium and front-access wiring is preferred. Feature → Business Impact → Application: Adjustable setting range of 35–50 A and a responsive TM release (TMA) delivers tailored protection curves, minimizing nuisance tripping and protecting critical loads in machine installations. Application: Suitable for distribution panels serving mixed-load environments where precise current settings improve uptime. Feature → Business Impact → Application: High electrical durability (up to 8000 cycles) and mechanical durability (up to 25000 cycles) extend service life, lowering maintenance costs and reducing replacement cycles in production lines. Application: Ideal for automated lines with frequent switching and routine protection checks. Feature → Business Impact → Application: Robust short-circuit performance with Ics up to 100 kA and Icu values across common voltages provides strong fault clearance, ensuring plant safety and continuity. Application: Suitable for feeders protecting transformers and large motors in industrial plants. Feature → Business Impact → Application: Integrated energy and environmental considerations, including EPDs, RoHS compliance, and a 55.7% recyclability rate, support regulatory compliance and sustainable procurement. Application: Favorable choice for green initiatives and supplier ESG programs. Feature → Business Impact → Application: Front-terminal design and standardized dimensions (120 mm W x 130 mm H x 82.5 mm D) enable straightforward replacement and compatibility with existing busbar systems (32.5–100 mm²). Application: Streamlines retrofits and upgrades in panel boards and protection blocks.

Get a Quick Quote for a ABB 1SDA067620R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067620R1? Enquire Now

FAQs

The unit accepts busbars from 32.5 to 100 mm² and uses front-terminal connections, making it straightforward to integrate into standard switchgear and motor control panels. Its 120 mm wide, 130 mm tall footprint aligns with common enclosure racks, reducing retrofit complexity and allowing faster commissioning in new builds.
Key specs include 50 A rated current, 690 V rated operating voltage, a setting range of 35–50 A, instantaneous trip setting 300–500 A, and short-circuit ratings up to 100 kA Ics depending on voltage. It also features 8 kV rated impulse withstand, 6 N·m tightening torque, and SACE Tmax XT front-terminal design for easy maintenance.
Yes. With 4 poles, front terminals, and a TMA release, it provides reliable transformer and motor protection, while its high Ics/Icu ratings support robust fault clearance. The device fits into transformer feeders and motor supply circuits in distribution panels, offering scalable protection aligned with IEC 60947-2.
It carries a CE declaration of conformity (EC DoC) and LR certification, and aligns with IEC 60947-2. ABB EcoSolutions data includes an EPD for Tmax XT XT2, RoHS and REACH declarations, and a recyclability rate of about 55.7%, supporting sustainable procurement and regulatory compliance.
Low maintenance is supported by high mechanical and electrical durability, reducing replacement cycles. Front-terminal access speeds wiring and service tasks, while the compact footprint simplifies retrofits. Overall, the combination of robustness, standard compliance, and eco-friendly attributes translates to minimized downtime and improved total cost of ownership.