Moulded Case Circuit Breaker ABB 1SDA067622R1 delivers reliable protection for low-voltage distribution panels in industrial facilities. Engineers often struggle with aligning fixed trip ranges and front-terminal wiring in dense switchgear. This device ships with CE conformity and LR and GL certificates, plus a DoC for Tmax XT2, assuring regulatory compliance. Designed for 690 V systems with 80 A nominal current, it supports safe, scalable protection while reducing installation time. In practice, this translates to improved uptime, easier maintenance, and a lower total cost of ownership for panel builders and integrators.

Product Information

Extended Description

1SDA067622R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 80 I3=400...800 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4080BFF000XXX
E-Number (Norway)
4379615
EAN
8015644015183
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.55 kg
Package Level 1 EAN
8015644015183
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 5.8 W
Rated Current (In)
80 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
400…800 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
56...80 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal, 4-pole fixed mounting with bolt terminals simplifies wiring access in crowded panels. Business Impact: reduces install time and wiring errors, enabling faster commissioning and easier maintenance. Application: ideal for SACE Tmax XT series protection in low-voltage distribution boards, switchgear, and transformer feeds, where reliable front-access wiring speeds up quality control. Feature: Thermomagnetic release TMA with adjustable instantaneous trip (I_i) 400–800 A and setting range 56–80 A. Business Impact: enables precise selective protection and coordination with upstream devices, reducing nuisance trips. Application: fits 80 A nominal rating and 690 V systems, suitable for motor drives, transformers, and feeders in industrial panels. Feature: High I_cs and I_cu ratings across voltages with Ui of 1000 V and a 690 V rated operational voltage. Business Impact: ensures robust short-circuit protection for essential feeders and transformers, maintaining system integrity during faults. Application: ideal for switchgear and distribution boards in factories and processing facilities. Feature: Mechanical and electrical durability with 8000 electrical cycles and 25000 mechanical cycles, plus a power loss of 5.8 W per pole. Business Impact: extended service life, reduced maintenance interventions, and predictable performance under frequent load changes. Application: suitable for continuous operation in busy industrial lines and data centers. Feature: RoHS and REACH compliance, along with EPD and disassembly guidance, supporting responsible end-of-life handling. Business Impact: helps meet sustainability and regulatory requirements while facilitating recycling. Application: preferred for OEM panels and retrofit projects seeking green credentials.

Get a Quick Quote for a ABB 1SDA067622R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067622R1? Enquire Now

FAQs

The 1SDA067622R1 is designed for 4-pole XT2 configurations with front-terminal bolt connections, suitable for 32.5–100 mm² busbars and 690 V systems. It integrates easily into Tmax XT switchgear, streamlining wiring, mounting, and future upgrades while maintaining compliant clearances and torque specifications.
Key specs include a rated current of 80 A, rated voltage of 690 V, setting range of 56–80 A, instantaneous trip setting 400–800 A, Ui of 1000 V, and Ics/Icu up to 15 kA at 690 V. The device also provides 8 kV impulse withstand and front-terminal bolt connections for reliable field performance.
Yes. The XT2 4P is designed for main distribution protection in panels feeding motors and transformers. Its adjustable I_i range enables selective coordination with upstream protective devices, while the front-terminal design aids rapid wiring and service access in motor control centers and transformer enclosures.
The product is covered by CE conformity (EC DoC Tmax XT2) and third-party certificates such as LR and GL, plus RoHS/REACH compliance. These certifications support regulatory alignment for European installations, ensure reliability in supply chains, and facilitate approvals for industrial applications requiring traceable compliance.
The combination of front-terminal wiring, precise protection settings, and high short-circuit withstand improves uptime and reduces rework. Typical benefits include faster commissioning, fewer nuisance trips due to better coordination, and lower maintenance costs over the lifecycle of the distribution panel.