ABB 1SDA067623R1 Moulded Case Circuit Breaker - IEC 60947-2
Part Number: 1SDA067623R1
Quick Summary
The ABB 1SDA067623R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for industrial switchgear and distribution panels. Engineers often face nuisance trips, inconsistent settings, and lengthy commissioning when integrating protective devices into complex networks. This XT2 family 4P unit offers a setting range of 70–100 A, a rated voltage of 690 V, and an 8 kV impulse withstand, supporting fast, predictable protection. It carries IEC 60947-2 conformity and CE declarations, with GL and LR certificates that ease cross-border compliance. The front-terminal design and TM release simplify installation and maintenance, delivering tangible business value through reduced downtime and faster upgrades across global sites.
Product Information
Extended Description
1SDA067623R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 100 I3=500...1000 A
Country of Origin
China (CN)
Lead Time
28 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4100BFF000XXX
E-Number (Norway)
4379616
EAN
8015644015190
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.55 kg
Package Level 1 EAN
8015644015190
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 8.08 W
Rated Current (In)
100 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
500…1000 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
70...100 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
4P XT2 fixed front-terminal design with busbar connections 32.5–100 mm² enables fast, tidy installations and reliable heat management. This wiring efficiency reduces installation errors and commissioning times on high-density distribution panels, especially in complex enclosures. With a rated power loss of 8.08 W per pole at rated conditions, the device helps minimize heat buildup and maintain performance under load. Front-accessible terminals also support safer, quicker field servicing in restricted installations. Key electrical ratings include 100 A nominal current, 690 V rated operational voltage, and 8 kV impulse withstand. The unit delivers an uninterrupted current rating of 160 A and short-circuit capacities up to 100 kA, supporting robust protection for feeders, transformers, and equipment in industrial plants. Its front-mount design and 6 N·m tightening torque ensure secure connections under vibration. This combination translates to reduced nuisance trips and better uptime in demanding environments. Setting range spans 70–100 A, and the instantaneous current setting (Ii) covers 500–1000 A, enabling precise coordination with upstream devices. Release is TM (TMA) with fixed front terminals, contributing to predictable tripping and rapid fault isolation. Compliance with IEC 60947-2 and support for the SACE Tmax XT family streamline integration in existing protection schemes, while the compact footprint supports easier retrofits in modernized facilities. Sustainability and compliance are strengthened by ABB EcoSolutions with an Environmental Product Declaration for Tmax XT XT2, a calculable recyclability rate (55.70% per EN45555), and RoHS/REACH declarations. End-of-life guidance and disassembly instructions help facilities reduce waste and simplify refurbishment. Combined with CE DoC and GL/LR certificates, these factors support regulatory alignment and reduce total lifecycle risk.
Get a Quick Quote for a ABB 1SDA067623R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067623R1?
Enquire Now
FAQs
Install the 4P XT2 with front terminals using busbars rated 32.5–100 mm², secure each connection to 6 N·m torque, and mount in a standard enclosure. Use the front TM release for commissioning and ensure the device sits within the 120 mm × 130 mm × 82.5 mm footprint for proper clearance and safe maintenance access.
It operates reliably at 690 V with 100 A nominal current and supports high fault resilience (Ics up to 100 kA, Iu 160 A). The front-terminal XT2 design, combined with 8 kV impulse withstand, provides predictable protection for feeders and transformers in industrial plants.
Key specs include 100 A In, 690 V Ur, Ui 1000 V, Uimp 8 kV, Ii 500–1000 A, Ics up to 100 kA, Icu up to 100 kA, and a setting range of 70–100 A. It is IEC 60947-2 compliant and designed for front-terminal mounting with a tightening torque of 6 N·m.
It carries IEC 60947-2 compliance, CE Declaration of Conformity, and certificates from GL and LR. ABB EcoSolutions provide environmental data (EPD), RoHS and REACH declarations, and end-of-life disassembly guidance to support regulatory alignment.
The unit's robust 100 kA short-circuit capacity and 8 kV impulse withstand reduce downtime from faults. Front-terminal wiring, 6 N·m torque, and a compact XT2 footprint speed installation and servicing, while 8.08 W power loss per pole improves thermal efficiency and reliability over long life cycles.