ABB 1SDA067627R1 Moulded Case Circuit Breaker - IEC 60947-2

Part Number: 1SDA067627R1
Manufacturer
ABB
Part number
1SDA067627R1

Quick Summary

Moulded Case Circuit Breaker ABB 1SDA067627R1 provides reliable protection for industrial power distribution and motor circuits. Designers often struggle to balance accurate trip settings, front-terminal installation, and quick procurement for critical protection. This unit aligns with IEC 60947-2 and offers CE conformity, LR and GL certificates for independent safety verification, plus robust DoC support for global markets. By leveraging ABB Sace Tmax XT technology, it delivers predictable performance in challenging environments while reducing downtime. For procurement teams, the compact footprint, four-pole protection, and front-terminal wiring translate into faster panel builds and easier serviceability across global sites.

Product Information

Extended Description

1SDA067627R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 160 I3=800...1600 A FULLY RATED NEUTRAL
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
AETAD009EXPU
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
BRABB008EXPU
Country of Origin
India (IN)
Lead Time
0 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
CHSEC006EXPU
Country of Origin
China (CN)
Lead Time
21 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
Country of Origin
India (IN)
Made To Order
No
Product Sales Status
Active
Quote Only
No
Stocked At Warehouses
INABB003EXPU
Warranty Return
Product under warranty must be returned
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
faa3f41f-8e61-4b91-a07b-0511a963944a Italy (IT)
Simplified SCIP
2e51e907-83e6-4d78-b1fd-6671f669fe1c Germany (DE) | 60a571f5-3995-40b3-bb49-1f11025e1807 Norway (NO) | c5ed6e67-4749-4b2d-932d-f3ef7de7429e Finland (FI) | dea9951f-fe91-4b90-a5ac-4c4b9aa83f4d Netherlands (NL) | 2fb06f6f-179e-4c09-8639-d4d63fecc4a1 Germany (DE) | 1ead897c-f009-4721-a055-fb14f0466a41 Denmark (DK) | aab8bcc9-e7a8-41b6-9b79-8c4a80db47e7 Netherlands (NL) | d31902ec-b49c-488c-8549-32b80cc76379 Netherlands (NL) | adaceaea-852c-429a-8d3e-671ac095aa06 Estonia (EE) | 5e7686f0-862d-484f-a2bb-643aec8a2b32 Greece (GR) | 3f6eb64c-9ef0-43b2-b18c-bf5730a12049 Portugal (PT) | 570d9a49-b217-4f41-ae89-8d7cefbacc00 Germany (DE) | d8cda10f-1790-4ebf-b4f3-be09afda7e3e Croatia (HR) | 7f4a32e3-1b4f-4d23-9f5d-d3bb9c4f57dc Czech Republic (CZ) | ab6edb75-3838-4598-9763-3b0f985814a8 Poland (PL) | 58b1600a-81c9-49d9-ad45-879c5081e6e8 Germany (DE) | f48e9ad7-4c91-4613-a6f1-d071cce66ee6 Germany (DE) | bba7cff5-5854-4af1-b8a0-591df187d1c6 France (FR) | de3ffc45-8d4a-4112-a65f-649200337fee Netherlands (NL) | 8abb20d7-4a55-4921-a3f3-5c6c59b130bb Spain (ES) | 31fd3c19-6def-462b-8679-a424495abf89 Netherlands (NL) | 4112504e-f9ca-4eb0-91fe-eeec620426ec Bulgaria (BG) | f90e61fc-0e9b-4145-aeb0-bff1c6ea6a91 Sweden (SE) | 25c39475-3da8-418b-bdaa-b30159b9c9ae Poland (PL) | 95c15571-9d49-4e79-ab92-f4228c724cdd France (FR) | 356a6754-a76d-4f59-ac81-3ce4e44deb82 Sweden (SE) | c1481159-c29c-431d-9a47-5e94a08d116c Poland (PL)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4160BFF000XXX
E-Number (Norway)
4379618
EAN
8015644015237
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
2.101 kg
Package Level 1 EAN
8015644015237
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 16.15 W
Rated Current (In)
160 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
800…1600 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
112...160 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Four-pole XT2 housing with front terminals streamlines wiring and saves panel depth, reducing assembly time and wiring errors in control panels and switchgear. This configuration supports reliable busbar connections and simplifies wiring routes in compact enclosures, enabling safer maintenance and faster commissioning in harsh industrial environments. Thermomagnetic release TMA provides precise coordination between overload and short-circuit protection. The result is minimized nuisance trips during transient faults while maintaining safety for motors and transformers, which translates into reduced downtime and longer equipment life. Current setting range of 112–160 A with a rated current of 160 A allows tailored protection for feeders and distribution boards. Combined with a front-connection type and bolt terminals, installation is straightforward and accessible for service technicians, enabling accurate field adjustments without rewiring. High short-circuit performance with Ics up to 100 kA and Icu ratings suitable for 690 V systems ensures transformer protection and motor feeders stay safe during faults. This capability supports compliance with IEC 60947-2, mitigating liability and enabling predictable fault clearance in demanding applications. Robust lifecycle documentation and certifications, including EC Declaration of Conformity and LR/GL attestations, support procurement and regulatory audits. The compact weight (1.6 kg) and dimensions (120 mm width x 130 mm height x 82.5 mm depth) also facilitate space-planning in modular panels and retrofits, reducing total installed cost.

Get a Quick Quote for a ABB 1SDA067627R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067627R1? Enquire Now

FAQs

Install with front-mounted bolt terminals, securing conductors per the 6 N·m tightening torque specification. Use the M6 screwdriver, ensure proper insulation, and verify that the unit is firmly seated in a compatible 4-pole slot. For safe commissioning, follow the XT2 installation instructions and confirm the device is wired for 690 V systems.
The device has a rated current In of 160 A with a setting range of 112–160 A. It supports a fault current setting Ii of 800–1600 A, rated voltage Ur of 690 V, and 8 kV rated impulse withstand. It also provides Ics up to 100 kA and Icu up to the levels specified for 230–690 V systems, ensuring robust protection.
Yes. It is designed for 690 V operation with compatible insulation and short-circuit performance. Its four-pole arrangement and front-terminal design make it ideal for transformer and motor feeder protection in switchgear, distribution panels, and industrial power circuits, meeting IEC 60947-2 requirements.
It supports CE conformity via EC Declaration of Conformity for Tmax XT2, plus LR and GL certificates for third-party safety verification. These attestations help with regulatory audits and supplier qualification, while the product documentation includes installation instructions and compliance statements.
The front-terminal bolt connections simplify wiring and reduce panel depth, enabling faster installation and easier field maintenance. With a compact 120 mm width, 130 mm height, and 82.5 mm depth, plus a 1.6 kg weight, this MCCB fits compact switchgear and retrofits, lowering total installed cost and improving serviceability in modular panel builds.