ABB 1SDA067642R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA067642R1
Manufacturer
ABB
Part number
1SDA067642R1

Quick Summary

ABB 1SDA067642R1 is a moulded case circuit breaker built for reliable low-voltage protection in industrial power distributions. It delivers three-pole protection with front-terminal access, simplifying wiring and maintenance in control panels. This device safeguards networks against overloads and short circuits with a 28–40 A setting range and a 690 V operating voltage, ensuring fast, predictable tripping. The product aligns with CE requirements and is supported by environmental declarations including EPD, RoHS and REACH, reinforcing compliance across markets. For buyers seeking lifecycle value, this XT2L unit integrates with the SACE Tmax XT family, offering durability and reduced downtime in demanding environments while supporting sustainable procurement goals.

Product Information

Extended Description

1SDA067642R1 ABB: C.BREAKER TMAX XT2L 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 40 I3=200...400 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2LE3040BFF000XXX
E-Number (Norway)
4379316
EAN
8015644015381
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.65 kg
Package Level 1 EAN
8015644015381
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.71 W
Rated Current (In)
40 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
300…400 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 18 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
28...40 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Front-terminal, fixed three-pole XT2L design enables quick installation and reliable wiring organization, reducing panel real estate and labor time. Business Impact → Shortened commissioning and easier maintenance translate to lower installed cost and faster project timelines. Application → Ideal for compact power distribution cabinets in industrial facilities where space is at a premium. Feature → Wide rated current and high protection settings with a 28–40 A range and 40 A nominal, plus a 690 V rating. Business Impact → Enables selective coordination and scalable protection for evolving load profiles, cutting nuisance trips and improving uptime in critical lines. Application → Suitable for transformers, motor feeders, and distribution boards in manufacturing and process industries. Feature → High short-circuit withstand with Ics up to 150 kA and Icu up to 150 kA across operating voltages. Business Impact → Enhances system resilience against faults, reducing substation downtime and equipment damage. Application → Particularly valuable in high fault-current environments like metalworking, plastics, and large motor drives. Feature → Compact footprint and sturdy build with 90 mm width, 130 mm height, 82.5 mm depth and 6 N·m tightening torque. Business Impact → Enables dense panel layouts and reliable connection integrity with front-terminal design. Application → Fits standard DIN enclosures and supports quick, serviceable installations. Feature → Compliance and end-of-life support with RoHS, REACH, EPD, packaging disposal guidance, and recyclable packaging considerations. Business Impact → Minimizes regulatory risk and supports sustainable product stewardship across the supply chain. Application → Useful for procurement teams seeking green, compliant components for European and global projects.

Get a Quick Quote for a ABB 1SDA067642R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067642R1? Enquire Now

FAQs

Install the 3P XT2L unit with front-terminal access, using a 6 N·m tightening torque on each bolt as specified. Connect busbar sizes between 32.5 and 100 mm² and ensure a secure, clean connection at the front terminals. Use a Main Circuit M6 screwdriver as recommended, and verify cable clearances to comply with enclosure standards.
Rated current is 40 A with a rated voltage of 690 V. Setting range is 28–40 A, rated operational voltage is 690 V AC / 500 V DC, and it provides short-circuit protection up to Ics 150 kA and Icu 150 kA (depending on voltage). It is a 3P device with a 3-pole configuration designed for reliable fault interruption.
Yes, the unit features CE conformity (EC Declaration of Conformity Tmax XT2). Environmental declarations include EPD for Tmax XT XT2 TM, RoHS compliance per EU directives, and REACH declarations. WEEE guidance and packaging disposal information are also provided to support end-of-life planning.
Yes, ABB Tmax XT family compatibility is supported, including XT2 variants with front-terminal mounting and fixed configuration. Installation considerations include front-terminal connections, busbar sizing 32.5–100 mm², and a compact footprint (90 mm W x 130 mm H x 82.5 mm D) to suit standard panels while maintaining performance under 690 V operating conditions.
Mechanical durability is rated at up to 25,000 cycles and electrical durability at up to 8,000 cycles under specified operating conditions, supporting longer service life with fewer replacements. The unit’s RoHS/REACH compliance, EPD, and disassembly guidance help reduce lifecycle risk and support sustainable maintenance programs.