ABB 1SDA067643R1 is a three-pole moulded case circuit breaker that protects industrial power distribution panels. This XT2 Tmax device integrates a front-terminal design with a TMA release for reliable protection and fast maintenance access. The challenge in modern panels is delivering consistent tripping performance while minimizing downtime and space. IEC60947-2, CE with a DoC, and GL/LR certificates back this unit, reinforcing compliance and traceability. In addition to ABB EcoSolutions support, the MCCB aligns with lifecycle cost reduction and predictable service intervals, making it suitable for controlled distribution in manufacturing environments while enabling straightforward upgrades to SACE Tmax XT families.

Product Information

Extended Description

1SDA067643R1 ABB: C.BREAKER TMAX XT2L 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 50 I3=250...500 A
Country of Origin
China (CN)
Lead Time
28 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2LE3050BFF000XXX
E-Number (Norway)
4379317
EAN
8015644695491
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644695491
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.09 W
Rated Current (In)
50 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
300…500 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 18 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Front-terminal XT2 three-pole MCCB enables easy wiring and faster installation in control panels and switchgear, reducing commissioning time and human error. Application: switchboards and motor control centers in heavy industry. Feature → Business Impact → Application: TMA release with fixed front terminals provides precise, reliable protection with straightforward servicing, improving uptime and safety. Application: transformer and distribution feeders requiring robust fault clearance. Feature → Business Impact → Application: 50 A nominal current with a selectable setting range of 35–50 A allows targeted protection for variable loads, minimizing nuisance tripping and improving overall process reliability. Application: feeders from MCCBs to motors and automation panels. Feature → Business Impact → Application: 690 V rated operational voltage and 1000 V insulation support high-voltage distribution with resilient arc quenching, reducing fault severity. Application: large industrial plants and process lines. Feature → Business Impact → Application: high Icu/Ics performance up to 150 kA at relevant voltages enables safe interruption under short-circuit conditions, protecting downstream equipment. Application: transformer protection, switchgear, and power distribution networks. Feature → Business Impact → Application: front-access, bolt terminal design with busbar compatibility 32.5–100 mm² enhances installation flexibility and reduces cabinet depth. Application: modular panel assemblies and retrofit projects. Feature → Business Impact → Application: IEC60947-2 compliance, CE DoC, RoHS/EcoSolutions data, and end-of-life documentation support regulatory compliance and sustainable waste management. Application: global manufacturing sites pursuing green procurement and circular economy targets.

Get a Quick Quote for a ABB 1SDA067643R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067643R1? Enquire Now

FAQs

Plan for front-terminal access and bolt connections. The unit supports busbars from 32.5 to 100 mm² and requires a tightening torque of 6 N·m. Dimensions and mounting depth align with standard XT2 panels, ensuring straightforward retrofit or new panel builds without rearranging existing components.
Rated current In is 50 A with a setting range of 35–50 A. Rated operational voltage Ur is 690 V, and rated insulation Ui is 1000 V. The device offers short-circuit protection with Icu up to 150 kA and disconnection capability suitable for three-phase distribution in industrial environments.
Yes. With 690 V UR, 3P configuration, and a fixed front-terminal arrangement, this MCCB is designed for three-phase power distribution, transformers, and motor protection in industrial facilities. The XT2 family provides reliable tripping, and the adjustable setting range supports motor load profiling and safe startup sequences.
The MCCB complies with IEC 60947-2 and carries a CE Declaration of Conformity. Additional certificates include GL and LR for structural integrity and a robust environmental profile with RoHS, CMRT, TSCA declarations, and EPD information under ABB EcoSolutions guidelines.
The front-terminal design simplifies wiring and servicing, reducing maintenance time. With a durable mechanical lifespan (up to 25,000 cycles) and electrical durability (up to 8,000 cycles per hour), the unit lowers downtime and extends service intervals, delivering a favorable total cost of ownership in high-availability industrial lines.