ABB 1SDA067645R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067645R1
Quick Summary
ABB 1SDA067645R1 Moulded Case Circuit Breaker is a high-reliability protection device for industrial electrical distribution. It interrupts power quickly to safeguard downstream equipment and maintain safe operations in demanding environments. This XT2L 3P F design delivers precise thermal‑magnetic protection with front terminals, enabling fast wiring and straightforward maintenance. It aligns with IEC 60947-2 and CE conformity, supported by LR and GL certificates for supplier qualification, with ABB EcoSolutions offering end‑of‑life and sustainability considerations. For panel builders and engineers, its plug‑and‑play compatibility within the SACE Tmax XT family translates to predictable performance and lower lifecycle costs.
Product Information
Extended Description
1SDA067645R1 ABB: C.BREAKER TMAX XT2L 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 80 I3=400...800 A
Country of Origin
China (CN)
Lead Time
37 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2LE3080BFF000XXX
E-Number (Norway)
4379319
EAN
8015644695507
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644695507
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 5.8 W
Rated Current (In)
80 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
400…800 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 18 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
56...80 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal 3-pole XT2L design with bolt terminals and 6 N·m tightening torque. Business Impact: Simplified wiring, faster panel assembly, and reliable torque for robust field connections. Application: Used in compact switchgear where space and accessibility matter. It lowers installation time and reduces rework in control panels. Feature: Setting range 56–80 A with a rated current of 80 A and a defined I_i of 400–800 A. Business Impact: Enables selective protection and coordinated breaker tripping, improving uptime and reducing unplanned outages. Application: Transformer and feeder protection in medium-sized distribution boards. Feature: High short-circuit ratings with I_cs up to 150 kA and I_u up to 18 kA (690 V). Business Impact: Enhanced fault tolerance for critical loads and transformers, minimizing equipment damage and downtime. Application: Industrial power distribution and motor feeder protection in demanding environments. Feature: Wide rated voltage and insulation (Ui 1000 V, U_r 690 V), plus Front connection and RoHS/REACH compliant materials. Business Impact: Broad applicability across 690 V systems with compliance, simplifying procurement and reducing regulatory risk. Application: Steel, chemical, and manufacturing facilities requiring compliant protection. Feature: ABB EcoSolutions compatibility with end-of-life guidance, disassembly instructions, and LRs/EPD data. Business Impact: Supports lower total cost of ownership through sustainable disposal, packaging optimization, and regulatory alignment. Application: Product lifecycle management in sustainable plant operations.
Get a Quick Quote for a ABB 1SDA067645R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067645R1?
Enquire Now
FAQs
Ensure front-terminal access with bolt-type terminals and tighten to 6 N·m to maintain fault-free connections. Use a compatible M6 screwdriver and prepare busbar sections within 32.5–100 mm² for optimal current transfer. Check panel clearance and support a stable mounting to prevent vibration-induced nuisance trips.
The device offers a setting range of 56–80 A with an I_i (instantaneous) of 400–800 A, allowing precise coordination with upstream devices. Selecting a higher I_i improves nuisance-tripping tolerance for non-fault inrush, while a lower setting increases protection sensitivity for fast fault clearing in feeders and transformers at 690 V.
Yes. With 3P XT2L construction, 690 V rating, and Ics up to 150 kA (and Icu up to 18 kA at 690 V), the XT2L is well-suited for transformer and feeder protection in robust distribution schemes. Its front-terminal design and compatibility with the SACE Tmax XT family streamline integration into transformer bays and control panels.
The breaker carries IEC 60947-2 compliance, CE Declaration of Conformity, and certificates such as LR and GL, supporting supplier qualification and traceability. Additional documentation includes EPD and RoHS/REACH declarations, along with end-of-life and disassembly guidance to satisfy environmental reporting and regulatory requirements.
ABB EcoSolutions provides end-of-life disassembly instructions, packaging disposal guidance, and potential zero-waste-to-landfill validation options. These resources help reduce waste, simplify recycling, and lower total cost of ownership through more predictable decommissioning, easier part replacement, and aligned environmental reporting.