ABB XT2L 1SDA067648R1 Moulded Case Circuit Breaker - 150 kA
Part Number: 1SDA067648R1
Quick Summary
ABB XT2L 1SDA067648R1 Moulded Case Circuit Breaker is designed for reliable overcurrent protection in industrial power distribution and transformer feed systems. Engineers often struggle with nuisance trips and equipment damage from surge events; this breaker delivers precise thermal-magnetic protection with front-terminal accessibility to reduce downtime and simplify maintenance. CE conformity is established, along with GL and LR certifications supporting global deployment, while RoHS and REACH declarations underscore compliance with modern environmental standards. The combination of IEC60947-2 alignment, adjustable I triggering, and robust Icu ratings translates into safer, more maintainable switchgear for panels and switchboards, while integrating smoothly with SACE Tmax XT product families for scalable protection strategies.
Product Information
Extended Description
1SDA067648R1 ABB: C.BREAKER TMAX XT2L 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 160 I3=800...1600 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2LE3160BFF000XXX
E-Number (Norway)
4379322
EAN
8015644015442
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.64 kg
Package Level 1 EAN
8015644015442
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 16.15 W
Rated Current (In)
160 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
80…1600 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 150 kA | (230 V AC) 150 kA | (240 V AC) 150 kA | (380 V AC) 120 kA | (415 V AC) 120 kA | (440 V AC) 100 kA | (500 V AC) 60 kA | (525 V AC) 36 kA | (690 V AC) 18 kA | (250 V DC) 2 Poles in Series 85 kA | (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
11.2...16 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Fixed three-pole XT2L frame provides consistent, dependable protection for busbar connections rated for 690 V AC and 500 V DC, minimizing arc flash risk and extending equipment life in critical power distribution. This solution supports a 160 A rated current and a 11.2–16 A setting range, enabling precise coordination with downstream protection devices while reducing nuisance trips and wiring disturbances in busbar trunking systems. Application wise, it suits transformer feeders, motor starters, and panelboards in manufacturing and process industries, driving reliability and operational continuity. Feature → Application → Benefit: Front-terminal, bolt-type connections with 6 N·m tightening torque simplify installation in tight spaces, improve fault-traceability during maintenance, and enable quick topping-up of torque to maintain connection integrity. Feature → Compliance → Value: IEC60947-2 standard compliance plus documented DoC ensures regulatory confidence for global sites, streamlining procurement and audit readiness. Feature → Durability → Outcome: Electrical durability up to 8000 cycles and mechanical durability up to 25000 cycles translate into lower maintenance costs and longer service intervals, reducing total cost of ownership in high-duty environments. Feature → Compatibility → Benefit: Busbar connection capacity 32.5–100 mm² and Moulded Case Breaker modularity fit common European and international panel designs, enabling plug-and-play upgrades without recabling, improving project timelines and reducing field engineering effort.
Get a Quick Quote for a ABB 1SDA067648R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067648R1?
Enquire Now
FAQs
This three-pole XT2L breaker uses front terminals with bolt connections and a specified tightening torque of 6 N·m, designed for compatible switchgear and panel layouts. It supports busbar connections from 32.5 to 100 mm², making it straightforward to retrofit into standard European or global panels without major rewiring. Ensure space for 130 mm height and 90 mm width in the panel frame.
Rated current is 160 A with a setting range of 11.2–16 A for the thermomagnetic release (TMA). The unit can withstand up to 690 V AC / 500 V DC, with a rated impulse withstand of 8 kV. Short-circuit capability is up to 150 kA (Icu) across relevant voltages, enabling reliable coordination with upstream protection and minimizing arc energy.
Yes. The XT2L is part of the Tmax XT family designed for transformer and generator protection in low-voltage to medium-voltage feeder applications. Its 3P fixed configuration with front terminals, high Icu ratings, and 690 V rating make it well-suited for transformer bays, switchgear feeders, and distribution panels in industrial facilities.
The unit carries CE conformity with the EC Declaration of Conformity for Tmax XT2, with additional GL and LR certificates supporting application in global industrial settings. It also documents RoHS and REACH compliance, CMRT for minerals reporting, and TSCA declarations, aiding regulatory approvals and sustainable procurement.
The XT2L offers high mechanical durability (up to 25000 cycles) and electrical durability (up to 8000 cycles), reducing false trips and downtime. Front-terminal design simplifies servicing, while compatible busbar connections speed up replacements. Together, these factors lower maintenance labor, replacement parts, and panel downtime costs over the equipment lifecycle.