Quick Summary

ABB 1SDA067770R1 is a moulded case circuit breaker for protecting 690V power distribution in industrial automation panels. Many engineers face unexpected outages from nuisance trips and difficult maintenance in growing control systems, which can drive downtime and maintenance costs. It aligns with IEC60947-2 and carries CE conformity, plus GL and LR certifications for global safety and reliability. As part of the SACE Tmax XT family, it features front terminals and a 3-pole design for streamlined installation and protective performance. This combination supports reliable machine protection and scalable panel design, delivering value across automation projects.

Product Information

Extended Description

1SDA067770R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MF Iu 1 A I3=14 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3001IFF000XXX
E-Number (Norway)
4379382
EAN
8015644016661
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644016661
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2 W
Rated Current (In)
1 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
14 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
MF
Release Type
M
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal connection in a fixed 3-pole XT2 design simplifies wiring and future maintenance, reducing commissioning time and wiring errors. This translates into lower labor costs and faster start-ups for OEM panel builds. Ideal for machine control panels and distribution enclosures, it minimizes field adjustments while improving safety during maintenance. High voltage readiness is built in with a rated 690 V AC and 500 V DC operational voltage, enabling safe protection across diverse industrial networks. Business impact: ensures compliance with international grid standards while reducing the need for separate components. Application: appropriate for LV distribution in automation lines, machine feeders, and transformer protection. Precise tripping performance is delivered by a MF release with a 14 A instantaneous setting and an uninterrupted current rating of 160 A. In practice this means faster fault isolation with minimal arc energy and reduced equipment damage. Application: motor protection, transformers, and heavy-load feeders where reliable short-circuit protection matters. Installation benefits come from front-terminal clamps sized for busbars 32.5 to 100 mm² and a tightening torque of 6 N·m per terminal. This supports robust, vibration-resistant connections in harsh environments and simplifies field adjustments. Application: panel builders and machine builders seeking durable connectivity. ABB notes environmental responsibility with an EPD for Tmax XT XT2 and a recyclability rate of ~55.7% per EN45555, supporting end-of-life planning. Business impact: helps meet corporate sustainability targets and regulatory reporting. Application: product selection for green building projects, industrial EPCs. Compliance and certification are integrated with IEC60947-2 and CE declarations, plus GL and LR certificates for global use. The product also provides disassembly instructions to support safe end-of-life handling.

Get a Quick Quote for a ABB 1SDA067770R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067770R1? Enquire Now

FAQs

Install the three-pole XT2 breaker with front-terminal access using a compatible M6 screwdriver. Ensure busbar sizing between 32.5 and 100 mm² and tighten each terminal to 6 N·m. Verify correct alignment with the panel cut-out, then perform insulation checks and functional testing to confirm proper tripping action and wiring integrity.
The unit is rated for 690 V (AC) and 1000 V (ultimate insulation), with a rated current of 160 A and instantaneous trip Ii of 14 A. It provides Ics up to 100 kA and Uimp of 8 kV, with a 50/60 Hz operating frequency. The device uses an MF magnetic release and is IEC60947-2 compliant.
Yes. The device is a 3P MCB in the SACE Tmax XT family designed for motor protection and distribution. Its MF release enables rapid fault isolation, while front-terminal access simplifies wiring in motor control centers and transformer feeder panels. Ensure the protection setting aligns with motor inrush and load characteristics for optimal performance.
This breaker carries CE conformity and a DoC, along with GL and LR certificates for global use. It is designed to IEC60947-2 standards, and ABB provides environmental declarations (EPD) and RoHS/REACH compliance. UL is not required for this model, but verify regional requirements as needed.
With 3P XT2 design, 6 N·m torque, front-terminal access, and a 160 A Iu rating, maintenance is streamlined and downtime is minimized. The device supports long service life under typical duty cycles (Electrical 120 cycles/hr; 8000 cycles mechanical) and helps reduce panel downtime, project risk, and spare-part costs through standardized components and reliable IEC60947-2 protection.