ABB 1SDA067771R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067771R1
Quick Summary
ABB 1SDA067771R1 Moulded Case Circuit Breaker protects critical switchgear in industrial power systems. Users often face lengthy lead times, difficult front-terminal access, and downtime during maintenance; this unit simplifies wiring and quick servicing. It aligns with IEC60947-2 and CE Declaration of Conformity, with RoHS and REACH compliance, supporting global installations and regulatory audits. Designed for SACE Tmax XT family integration and motor-protection duties, it supports efficient panel assembly and reliable protection across 690 V systems, helping engineers reduce commissioning time and improve site safety. The combination of a front-terminal design, MF magnetic release, and robust ratings makes it a practical choice for demanding environments where uptime matters and total cost of ownership matters.
Product Information
Extended Description
1SDA067771R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MF Iu 2 A I3=28 A
Country of Origin
China (CN)
Lead Time
67 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3002IFF000XXX
E-Number (Norway)
4379383
EAN
8015644016678
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644016678
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.38 W
Rated Current (In)
2 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
28 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
MF
Release Type
M
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal, fixed-three-pole design simplifies panel wiring and reduces installation time. This configuration delivers secure bolt connections and straightforward service access, which translates to less downtime during maintenance and faster fault isolation in high-density control panels. High-power ratings provide wide protection coverage: rated operational voltage of 690 V and an Iu of 160 A, with a 28 A instantaneous setting Ii. The result is reliable protection for transformers, motors, and distribution feeders without oversizing components. Compliance and sustainability features reduce risk and lifecycle cost. IEC60947-2 compatibility, CE conformity, REACH and RoHS declarations help meet global regulatory requirements, while ABB EcoSolutions and disposal guidance support responsible end-of-life management. Durability and responsiveness improve system reliability. With a mechanical durability of up to 25,000 cycles and an opening time around 30 ms, operators gain confidence in quick, precise trips. The device also offers a clear tripping curve and a MF release for fast fault containment. Installation and compatibility advantages extend across industrial applications. Busbar connections accept 32.5–100 mm², tightening torque is 6 N·m, and the recommended main-circuit screwdriver is M6, all contributing to consistent assembly quality and reduced commissioning risk. Lifecycle and packaging considerations: packaging level information indicates box packaging with 1 piece per box, 67 day lead time, and clear origin data to simplify procurement and warehouse planning.
Get a Quick Quote for a ABB 1SDA067771R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067771R1?
Enquire Now
FAQs
Install the MCCB using the front-terminal configuration to streamline wiring. Route busbars for 32.5–100 mm² conductors, tighten terminals to 6 N·m, and use an M6 screwdriver as recommended. This setup minimizes wiring errors, reduces commissioning time, and improves serviceability during routine maintenance and fault finding in dense panels.
Key ratings include rated operational voltage of 690 V, rated current In of 2 A, rated uninterrupted current Iu of 160 A, and rated instantaneous current Ii of 28 A. Its Ics and Icu values vary by voltage but provide up to 100 kA short-circuit capacity at 220–240 V and up to 70 kA at higher voltages, enabling appropriate protection sizing.
Yes. The ABB 1SDA067771R1 is part of the SACE Tmax XT XT2 family with motor protection capabilities. Its three-pole fixed-front-terminal design, MF release, and 690 V rating make it well-suited for protecting motors and associated switching gear in industrial panels, reducing nuisance trips and extending motor life when correctly coordinated with load characteristics.
This MCCB meets IEC60947-2, with CE Declaration of Conformity, RoHS and REACH declarations, and CMRT/TSCA disclosures where applicable. These certifications support global deployment, regulatory audits, and responsible supply-chain practices, while providing assurance of environmental compliance and product safety throughout its lifecycle.
Maintenance benefits include front-access replacement and quick fault isolation, reducing downtime. Lifecycle considerations cover long-term reliability with up to 25,000 mechanical cycles, a 30 ms opening time, and clear tripping characteristics. End-of-life guidance is provided via disassembly instructions, packaging disposal information, and EPD/ recyclability data to support sustainable asset management.