ABB 1SDA067773R1 Moulded Case Circuit Breaker provides reliable overcurrent protection for 690 V power distribution. Engineers often struggle with coordinating protective devices as systems evolve and uptime is critical. This XT2 three-pole unit aligns with IEC 60947-2 and CE conformity, and ABB EcoSolutions programs provide clear end-of-life and recycling guidance. By leveraging its front-terminal design and precise MF magnetic release, it simplifies installation and maintenance, reducing wiring errors and downtime. The product supports global compliance with RoHS, REACH, and environmental disclosures (EPD), while its compact form and modular ratings enable scalable protection for transformers and motors across diverse industrial settings.
Product Information
Extended Description
1SDA067773R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MF Iu 8,5 A I3=120 A
Country of Origin
China (CN)
Lead Time
28 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
afdb0039-93cd-4f18-9e0c-6f67aee97d39 Italy (IT)
Simplified SCIP
ea4f4598-773d-4638-92c4-0fb94ca2769a Germany (DE) | 9602d867-7222-46ac-967c-df9fbb8693fc Norway (NO) | 54f7b842-e410-4b9e-9f72-f0ba991e5f4b Finland (FI) | f276ab25-3001-4ae9-9c56-2443adfb77ae France (FR) | eb474ee5-4211-4d32-baea-91c834bd697f Netherlands (NL) | 95521afe-f3b5-4b29-8477-2e4529ee48b1 Spain (ES) | 7c32f442-fbaa-4202-b600-61d7fc796c71 Netherlands (NL) | c868e4b5-9316-4f07-814d-91223b342d79 Bulgaria (BG) | 45a77212-9c9a-4ce8-ad63-d1a639aaae59 Sweden (SE) | 474612a3-b7e1-40e1-a720-da1a198bacd2 Poland (PL) | 59db77ac-618b-47ab-800a-02bfaf1da8ba France (FR) | 93be2516-88c4-4fbc-ad12-b4e1e5209bf5 Sweden (SE) | 1339624f-0675-4bf9-aadd-99b7e25f8389 Poland (PL) | f9fb075c-b48f-45b3-bb78-7540efcfd883 Germany (DE) | 487dd262-6556-41a6-ba31-276b763b4d8f Croatia (HR) | 44525e92-a915-42dc-8a35-384fd4f8ffbf Czech Republic (CZ) | 39c64dcc-5ae6-4338-9b27-034ad5e01ae3 Poland (PL) | e4198f20-05d9-4826-b6c5-6eec9d66d8a5 Netherlands (NL) | 5f136e26-8f32-4abc-a52d-f744ff770d6a Germany (DE) | 9de4a76a-2c42-4abf-844c-da94cfc85d37 Germany (DE) | 7d63820e-dceb-4623-93db-01d02ebadd00 Netherlands (NL) | 17ce48d6-892e-4455-abff-cb5db1150e7c Germany (DE) | 0c8c8f06-56ad-4f21-bdf3-a35a3acdf798 Denmark (DK) | 5a1320ef-cfb2-4bce-983d-9674a23c8a0a Netherlands (NL) | c9cae246-d439-4423-9b61-72651086d844 Estonia (EE) | da071219-62cd-40e8-a5b6-c82a96dfc8f4 Greece (GR) | 54573e89-9e20-40dd-b06e-f483c4a977c0 Portugal (PT)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3009IFF000XXX
E-Number (Norway)
4379385
EAN
8015644016692
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644016692
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.9 W
Rated Current (In)
8.5 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
120 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
MF
Release Type
M
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature & Benefit driven narrative: Front terminals and fixed three-pole design enable fast, safe wiring with reduced installation errors, improving panel build time and reliability in control cabinets. Business impact: shorter commissioning windows and lower labor costs on installations. Application: new installations and retrofits in HVAC, process, and automation systems. Feature: Rated current of 8.5 A (In) with 690 V operating voltage; Benefit: precise protection for low-to-medium power circuits with minimal nuisance tripping. Application: maintenance-friendly motor feeders and transformer protections in distributed power networks. Feature: Ics up to 70–100 kA and Icu up to 100 kA across voltages; Benefit: robust fault-handling performance and high availability in critical loads. Application: transformer, generator, and equipment protection in industrial plants. Feature: Uo 690 V AC / 500 V DC and Ui 1000 V; Benefit: wide insulation margins support diverse supply networks and safer operation. Application: cross-country deployments and energy-intensive facilities. Feature: Front terminal connections with 6 N·m tightening torque; Benefit: secure, service-friendly wiring with consistent torque management. Application: equipment upgrades and panel maintenance. Feature: 2.9 W power loss per pole; Benefit: energy-efficient protection reducing heat and cooling requirements. Application: continuous operation in energy-conscious facilities. Feature: RoHS, REACH claims and EPD availability; Benefit: regulatory compliance and sustainable product lifecycle. Application: international procurement and environmental reporting. Feature: 3P XT2 sub-type with MF release; Benefit: precise, fast operation and compatibility with ABB Tmax XT family. Application: motor and transformer protection in critical systems.
Get a Quick Quote for a ABB 1SDA067773R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067773R1?
Enquire Now
FAQs
This unit uses fixed front terminals designed for straightforward connection to busbars in 32.5–100 mm² range. Ensure tightening torque is 6 N·m per terminal and follow the installation instructions XT2 for safe mounting and correct polarity. The MF release should be wired per the label to ensure proper tripping performance.
Rated current In is 8.5 A, rated insulation voltage Ui is 1000 V, rated operational voltage is 690 V AC / 500 V DC. Ics (rated service short-circuit breaking capacity) can reach up to 70–100 kA depending on voltage, and Icu (rated ultimate short-circuit breaking capacity) can be up to 100 kA at applicable voltages.
Yes. It adheres to IEC 60947-2 and has an EC Declaration of Conformity for Tmax XT2, supporting CE compliance. This alignment ensures compatibility with international electrical protection schemes and regulatory expectations.
It is ideal for motor and transformer protection in low-voltage distribution, especially in panel installations requiring front-terminal connections, compact footprint, and robust fault protection for 50/60 Hz systems.
The device supports RoHS and REACH declarations, offers an Environmental Product Declaration (EPD), and has a recyclability rate per EN45555. It aligns with ABB EcoSolutions, including end-of-life disassembly guidelines.