ABB 1SDA067777R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA067777R1
Manufacturer
ABB
Part number
1SDA067777R1

Quick Summary

ABB 1SDA067777R1 Moulded Case Circuit Breaker protects industrial power circuits. Engineers often struggle with sourcing a compact MCCB that combines reliable fault interruption, front-terminal wiring, and straightforward maintenance. This device meets IEC 60947-2 and CE conformity, with LR certification, and supports 690 V systems, aided by a 52 A rating and MA magnetic release for motor protection. For panel builders and machine integrators, it offers installation versatility, robust protection, and a clear path to lifecycle efficiency through ABB EcoSolutions.

Product Information

Extended Description

1SDA067777R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 52 A I3=314...728 A
Country of Origin
China (CN)
Lead Time
21 day
Made To Order
No
Warranty Return
Product under warranty must be returned
Product Sales Status
Inactive
Quote Only
No
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3052MFF000XXX
E-Number (Norway)
4379389
EAN
8015644016739
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.658 kg
Package Level 1 EAN
8015644016739
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
52 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
312…728 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
MA
Release Type
M
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Three-pole XT2 design with MA magnetic release delivers fast, selective protection, reducing downtime and safeguarding motors in demanding production environments. Front-terminal bolt connections simplify wiring and commissioning while maintaining a secure, vibration-resistant interface, with a recommended tightening torque of 6 N·m to ensure reliable contact over the life of the installation. The unit is rated for 690 V and 50/60 Hz networks, supporting a wide range of industrial feeders and motor circuits with busbar connections from 32.5 to 100 mm², enabling flexible panel layouts and future scalability. High short-circuit robustness, with Icu up to 100 kA and Ics values suitable for many medium-power applications, provides a safe and predictable response during fault events, reducing downstream damage and service interruptions. Regulatory compliance and sustainability features—IEC60947-2, CE conformity, and ABB EcoSolutions—help meet industry standards while supporting green manufacturing through responsible end-of-life and packaging practices.

Get a Quick Quote for a ABB 1SDA067777R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067777R1? Enquire Now

FAQs

The ABB 1SDA067777R1 uses front-terminal bolt connections designed for straightforward panel mounting. Ensure busbar sizing between 32.5 and 100 mm² and tighten terminals to 6 N·m. Verify vertical clearance and door access for front wiring, then test mechanical operation and electrical trip under supervised conditions to confirm correct assembly and coordination with upstream protection devices.
Key specs include a rated current of 52 A, rated voltage of 690 V, and rated impulse withstand voltage of 8 kV. The device offers 50/60 Hz operation, three poles, front-terminal bolt connections, and a tightening torque of 6 N·m. Short-circuit performance supports high fault isolation, with Icu up to 100 kA depending on system voltage.
Yes. As a three-pole XT2 molded case breaker with MA release, it provides fast, selective motor protection and safe disconnection in motor drives, pumps, and fans. Its 690 V rating suits industrial power networks, while front-terminal wiring and tight enclosure dimensions support integration into motor control centers and switchgear for HVAC and transformer protection schemes.
The device is CE compliant with IEC60947-2 standards and carries LR and GL certificates as part of its documented compliance. Data also notes an EC Declaration of Conformity for Tmax XT2, and ABB EcoSolutions alignment supports environmental declarations. UL and additional local certifications vary by region, so check country-specific requirements when procuring.
Lead time is listed as 21 days, with a minimum order quantity of one piece. For US and Canada, an order code XT2HE3052MFF000XXX is provided in the data, enabling streamlined quoting and dispatch. Packaging is one piece per box, with an EAN of 8015644016739 for cross-border logistics.