ABB 1SDA067778R1 Moulded Case Circuit Breaker is a high‑reliability protective device for industrial power distribution and motor protection. Engineers value fast, selective tripping to minimize downtime and prevent cascading faults, especially in networked plants. This XT2 device is conformant with IEC 60947-2 and CE, with GL and LR certificates supporting global deployments. As part of the SACE Tmax XT family, it offers front-terminal installation, robust 3P protection, and a defined trip range that speeds commissioning and reduces total cost of ownership. The unit’s 80 A In, Ui 1000 V, Icu 100 kA, and 5.8 W per pole heat loss deliver reliable performance even in demanding environments, while RoHS and REACH declarations support sustainability goals.
Product Information
Extended Description
1SDA067778R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND MAGNETIC RELEASE MA Iu 80 A I3=480...1120 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 TM
Environmental Product Declaration - EPD
EPD Tmax XT XT2 TM (CN) | EPD Tmax XT XT2 TM (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3080MFF000XXX
E-Number (Norway)
4379390
EAN
8015644016746
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.2 kg
Package Level 1 EAN
8015644016746
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 5.8 W
Rated Current (In)
80 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
480…1120 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC | 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA | (250 V DC) 2 Poles in Series 70 kA | (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
MA
Release Type
M
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal bolt connections with a 6 N·m tightening torque provide a vibration‑tolerant, secure install, reducing post‑installation retightening and speeding commissioning in control panels. This feature translates to lower field labor costs and improved uptime in mission‑critical motor feeders. The 3P XT2 platform protects distribution and transformer circuits with an instantaneous current setting of 480–1120 A and a rated short‑circuit breaking capacity (Icu) of 100 kA, delivering selective, fast clearing to minimize arc energy and equipment damage. With rated current of 80 A and rated operational voltage of 690 V (50/60 Hz), it supports reliable operation across standard industrial feeders while simplifying panel design and stock keeping. Power loss of 5.8 W per pole reduces heat generation and cooling requirements, supporting overall energy efficiency and healthier enclosures. Compatibility with 32.5–100 mm² busbars and front termination makes retrofits straightforward, lowering installation risk and enabling phased modernization of existing panels. ABB EcoSolutions and documentation, including EPD, RoHS/REACH declarations, and disassembly instructions, provide a clear path to sustainable end‑of‑life management, reducing lifecycle cost and environmental impact. The device follows IEC 60947‑2 standards and is part of the SACE Tmax XT family, ensuring consistent performance across similar breakers and easy cross‑cabinet interoperability for multi‑line protection schemes. Overall, these features offer a robust, future‑proof protection solution with predictable maintenance cycles and a clear path to compliance and efficiency gains.
Get a Quick Quote for a ABB 1SDA067778R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067778R1?
Enquire Now
FAQs
Install with front-terminal bolts and torque to 6 N·m using a Main Circuit M6 screwdriver. Verify busbar connection within 32.5–100 mm², ensure correct alignment of the 3P terminals, and tighten each bolt to spec to prevent hotspots and vibration‑induced loosening. Reference the CAD dimensional drawing XT2 3p FIXED F for mounting clearance and wiring routes.
Key specs include In of 80 A, Ui 1000 V, Um 690 V, Ii 480–1120 A, Icu up to 100 kA, and Ics ratings that support selective tripping in multi‑branch feeders. The device also features an 8 kV impulse withstand and 30 ms opening time, making it suitable for motor protection and distribution in demanding industrial environments.
Yes. The XT2 3P design is intended for motor protection and transformer/generator installation protection within 690 V systems. It offers front-terminal mounting, reliable 3P coordination, and a wide instantaneous current setting range, enabling selective tripping to minimize downtime and equipment damage in high‑loads environments.
The unit carries CE conformity with IEC 60947‑2 certification and is supported by GL and LR certificates for global use. Environmental documentation includes RoHS and REACH declarations, an EPD for Tmax XT XT2, CMRT for conflict minerals, and TSCA declarations, plus recyclability data per EN45555.
Front-terminal design simplifies wiring, speeds retrofits, and reduces enclosure depth requirements. With a 6 N·m tightening torque and compatible 32.5–100 mm² busbars, field upgrades are faster and more reliable. Low per‑pole power loss (5.8 W) reduces cooling load, contributing to lower operating costs over the product’s lifecycle.