ABB 1SDA067857R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067857R1
Quick Summary
ABB 1SDA067857R1 Moulded Case Circuit Breaker protects low-voltage power distribution panels in demanding environments. Users often struggle with nuisance trips and time-consuming installation in compact control spaces. This device aligns with IEC 60947-2, CE conformity, and GL/LR certifications to ensure robust regulatory compliance and traceability. By offering front-terminal access, a 3P configuration, and a 690 V rating, it simplifies wiring and reduces installation time. For panel builders and maintenance teams, the result is faster commissioning, predictable protection, and lower lifecycle costs through reliable performance and streamlined servicing.
Product Information
Extended Description
1SDA067857R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP DIP LS/I R 10 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
e95d5b08-b2d5-474a-b781-4a66eb75e3ef China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3010EFF000XXX
E-Number (Norway)
4379428
EAN
8015644017538
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.12 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644017538
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.1 W
Rated Current (In)
10 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
Ekip Dip LS/I
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SDC210100D0206 | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: 3-pole XT2 design provides coordinated protection across three phases, improving system reliability and reducing fault-related downtime in distribution panels. This aligns with 690 V AC system requirements, enabling safe integration in industrial controls and machine builders' panels. Feature → Front-terminal connection enables faster, tool-friendly wiring and maintenance access, cutting labor time by minutes per install and simplifying field upgrades in confined enclosures. Application: Suitable for compact switchgear layouts where space is at a premium and fast maintenance is critical. Feature → 10 A rated current with 8 kV impulse withstand supports predictable protection for small to mid-size loads, reducing nuisance trips while maintaining safety. Application: Ideal for MCCs and control panels handling moderate motor loads in manufacturing lines. Feature → SACE Tmax XT lineage (XT2), with clean disassembly instructions and ECO-solutions data, supports sustainability goals and end-of-life planning. Application: Modern factory retrofits requiring traceable recyclability and responsible disposal. Feature → Compliance with IEC60947-2 and CE declarations ensures regulatory alignment and customer confidence in procurement specs. Application: OEMs seeking verified conformity for safety-critical equipment. Feature → Mechanical durability of up to 25,000 cycles and electrical durability up to 8,000 cycles per hour supports long service life in continuous operation environments. Application: Critical for high-use protection in packaging and processing lines. Feature → Front-terminal, bolt-type connections with recommended M6 driver improve connection integrity and torque accuracy, reducing the risk of loose terminations under shock and vibration. Application: Suitable for demanding industrial environments with frequent power cycling. Feature → Accurate tightness torque specification of 6 N·m ensures consistent performance and reduces maintenance variance. Application: Essential for panel builders aiming for repeatable installation quality. Feature → Comprehensive documentation and dimensional diagrams (XT2 3p-4p fixed front terminals) enable precise enclosure planning and rapid installation. Application: Fast-fit projects and standardization across multi-line deployments.
Get a Quick Quote for a ABB 1SDA067857R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067857R1?
Enquire Now
FAQs
This XT2 3P device uses front-terminal connections designed for quick wiring. Ensure the panel enclosure allows 90 mm width and 82.5 mm depth clearance. Use the recommended M6 screwdriver for securing bolts and tighten to 6 N·m. Follow the XT2 mechanical drawings for precise mounting positions and clearance to avoid thermal or mechanical interference.
The unit offers rated operational voltage of 690 V AC and a rated current of 10 A, with a short-circuit breaking capacity suitable for several distribution scenarios. It provides 8 kV impulse withstand, ensuring resilience against transient spikes. For critical loads, verify the Ics/Icu values per your system voltage to select appropriate protection settings.
Yes, as a 3P XT2 molded-case breaker, it fits motor control panels and MCCs needing reliable overcurrent protection. Check the motor inrush and load current against the 10 A rating, and use proper wiring from busbars 32.5 to 100 mm². The front-terminal design supports fast, service-friendly installation in dense control cabinets.
The device provides a CE declaration of conformity for Tmax XT2 and has GL and LR certificates listed in the data. IEC 60947-2 is the governing standard, with additional documentation such as the SACE Tmax XT technical characteristics. While UL certification is noted as not required in this listing, always verify local regulatory requirements for your region.
ROI comes from improved fault isolation, reduced downtime, and easier maintenance with front-terminal access. The XT2’s durable mechanical and electrical performance reduces replacement frequency, and the packaging and documentation enable faster upgrades. With a 10 A rating aligned to typical control loads, you can optimize protection without oversizing, lowering capex and ongoing energy losses.