ABB 1SDA067861R1 Moulded Case Circuit Breaker protects low-voltage distribution panels and motor circuits. Engineers often face downtime when upgrading to compliant, space-efficient protection devices that install quickly. This XT2 family member aligns with IEC60947-2 and CE conformity, and carries LR and GL certifications for added confidence in safety and performance. By combining robust protection with front-terminal wiring and a compact footprint, it reduces panel space, simplifies maintenance, and supports faster commissioning. The device also meets RoHS and REACH requirements, with a 160 A rating and 690 V operating voltage, delivering reliable protection in demanding industrial environments while integrating with ABB EcoSolutions initiatives for sustainable operations.
Product Information
Extended Description
1SDA067861R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP DIP LS/I R 160 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
ca534c73-387e-461f-9694-2544fbf22775 China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3160EFF000XXX
E-Number (Norway)
4379432
EAN
8015644017576
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.704 kg
Package Level 1 EAN
8015644017576
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 10.8 W
Rated Current (In)
160 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
Ekip Dip LS/I
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SDC210100D0206 | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: 3-pole XT2 design with front terminals delivers robust protection for three-phase circuits. Business Impact: simplifies wiring and reduces installation time, enabling faster panel assembly and lower labor costs. Application: motor feeders and distribution panels in manufacturing lines. Feature: 160 A rated current and 690 V rating with IEC60947-2 standard ensures safe switching and reliable protection across typical plant voltages. Impact: prevents nuisance trips and extends equipment life. Application: transformer and switchgear protection in process plants. Feature: Ekip Dip LS/I release option provides reliable tripping with front-terminal mounting. Impact: quick field testing and maintenance with predictable operation. Application: emergency shutdown circuits in automation racks. Feature: Front terminal and Bolt terminal type supports secure, vibration-resistant connections. Impact: reduces torque-related failures in harsh environments. Application: control cabinets in heavy industry. Feature: Busbar connection range 32.5 to 100 mm² improves compatibility with common panel busbars. Impact: lowers custom wiring needs and speeds installation. Application: new panel builds and retrofit projects. Feature: Power loss of 10.8 W per pole enhances energy efficiency in continuous operation. Impact: lower running costs and reduced heat in switchgear enclosures. Application: power distribution blocks and main feeders. Feature: Tightening torque of 6 N·m ensures consistent, reliable connections. Impact: fewer maintenance calls due to loose connections. Application: high-vibration environments. Feature: Dimensions 90 mm W x 130 mm H x 82.5 mm D and weight 1.4 kg. Impact: compact footprint enables denser panels and easier handling. Application: space-constrained control rooms.
Get a Quick Quote for a ABB 1SDA067861R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067861R1?
Enquire Now
FAQs
For straightforward installation, use the front terminals with bolt connections and tighten to 6 N·m. The unit supports busbar connections from 32.5 to 100 mm², enabling clean, space-efficient wiring in compact panels. Ensure panel mounting follows the dimensions 90 mm by 130 mm by 82.5 mm and allow for the 1.4 kg weight during handling. This minimizes downtime and supports quick commissioning.
Key specs include a 160 A rated current, 690 V rated operational voltage, 50/60 Hz compatibility, and Ics up to 100 kA across applicable voltages. With a fast opening time and low power loss (10.8 W per pole), the device protects motors from short-circuit events while minimizing heat and energy costs within the switchgear.
Yes. The 3P XT2 breaker is designed for low-voltage protection in distribution panels and feeder circuits, with 690 V operating voltage and robust short-circuit withstand capabilities. Its front-terminal design and reliable tripping release (Ekip Dip LS/I) simplify integration into transformer protection schemes and ensure safe, code-compliant operation.
The device aligns with IEC60947-2 and CE declarations for conformity. It also carries LR and GL certificates for enhanced safety assurances. Additionally, it supports RoHS and REACH compliance and offers end-of-life considerations through ABB EcoSolutions, including disassembly guidance and DfX strategies for sustainable recycling.
Maintenance benefits include front-access wiring, modular front-terminal design, and predictable opening times (30 ms variants) that simplify testing. The compact footprint and low power loss reduce cooling needs, contributing to energy savings. Long-term ROI comes from lower downtime, easier replacements within the SACE Tmax XT family, and compliance with global standards reducing regulatory risk.