ABB 1SDA067862R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA067862R1
Manufacturer
ABB
Part number
1SDA067862R1

Quick Summary

ABB Tmax XT XT2 3P molded case breaker protects electrical distribution panels in industrial facilities. This design helps maintain consistent protection while reducing nuisance trips in complex panel layouts. The device aligns with IEC 60947-2 and CE conformity, with LR and GL certificates supporting reliability and long life in demanding environments. Front-terminal installation, compact 3P footprint, and a 10 A rated current deliver straightforward wiring and predictable protection for transformers, MCCs, and motor circuits. By combining robust protection with easy serviceability, this solution translates to reduced downtime and lower total cost of ownership for industrial facilities.

Product Information

Extended Description

1SDA067862R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP M DIP I R 10 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
161e5260-e6a6-4657-b0b9-ae9b41ad0610 China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3010JFF000XXX
E-Number (Norway)
4379433
EAN
8015644017583
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.12 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644017583
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.1 W
Rated Current (In)
10 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
Ekip M Dip I
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SDC210100D0206 | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The XT2H 160 design provides three-pole protection at 690 V with front terminals, enabling fast, safe wiring and reliable disconnection in space-constrained switchgear; this reduces assembly time and wiring errors in new installations and retrofits. Application: control panels, switchboards, and MCCs in chemical, metal, and process industries where panel density is high and safety margins are critical.Feature → Business Impact → Application: Rated current of 10 A with a measured power loss of 0.1 W per pole improves thermal management and energy efficiency, contributing to cooler enclosures and lower operating costs over the device lifecycle. Application: low- to medium-load protection in distributed power circuits and control circuits within manufacturing lines.Feature → Business Impact → Application: High short-circuit performance with Ics up to 100 kA at lower voltages and 15 kA at 690 V ensures fast, selective disconnection, reducing fault propagation and equipment damage. Application: transformer and feeder protection in medium- and high-voltage distribution networks.Feature → Business Impact → Application: Ekip M Dip I release and EL release type provide flexible coordination and reliable tripping, supporting safer maintenance and easier troubleshooting. Application: motor feeders and distribution feeders requiring precise protection coordination in automated cells.Feature → Business Impact → Application: RoHS, REACH declarations and EKP/EPD coverage validate sustainability and regulatory compliance, lowering risk with auditors and customers. Application: public-sector and automotive supplier environments where green compliance matters.Feature → Business Impact → Application: Front-terminal connection and a recommended M6 driver with a 6 N·m tightening torque enable fast, repeatable installation with consistent torque control. Application: new installations and retrofit projects in existing panels where wiring changes are frequent and downtime must be minimized.

Get a Quick Quote for a ABB 1SDA067862R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067862R1? Enquire Now

FAQs

The XT2H 160 3P is designed for industrial panel protection in 690 V systems, including MCCs, distribution boards, transformers, and motor control circuits. With front-terminal design and a 10 A rating, it enables quick wiring, safer maintenance, and reliable fault isolation in space-limited switchgear environments.
Key ratings include rated current 10 A, rated voltage 690 V, and operating voltage 690 V AC. Short-circuit performance ranges from 15 kA at 690 V to 100 kA at lower voltages (e.g., 230–240 V), enabling selective protection and reduced risk of cascading faults in power distribution networks.
Compliance is supported by IEC 60947-2 standards, CE Declaration of Conformity, and eco-related declarations (RoHS, REACH, EPD). The design also notes recyclability considerations and packaging disposal guidance, aligning with sustainability initiatives and regulatory audits typical in highly regulated industries.
Install with front-terminal connections suitable for busbars 32.5–100 mm². Use a M6 screwdriver and apply a tightening torque of 6 N·m to ensure reliable contact. The unit supports quick wiring, compact enclosure footprint, and straightforward field maintenance, which helps minimize downtime during upgrades or routine servicing.
The XT2H 160 features robust electrical and mechanical endurance ratings, plus disassembly instructions for end-of-life servicing. With modular release options (Ekip M Dip I) and documented maintenance procedures, customers gain predictable lifecycle costs, easier spare-part planning, and safer, longer-lasting protection for critical power paths.