ABB 1SDA067863R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067863R1
Quick Summary
ABB 1SDA067863R1 Moulded Case Circuit Breaker protects 690 V power circuits in industrial equipment. It addresses downtime caused by mis-wiring and unreliable trips by offering front-terminal access and a robust Ekip M Dip I release for dependable disconnection. This device meets IEC 60947-2 and CE declarations, with UL and other certifications available as needed. By aligning with the SACE Tmax XT family and a front-terminal XT2 configuration, it delivers safe installation, fast maintenance, and lifecycle cost efficiency for panel builders and machine integrators. In short, it combines reliability, regulatory alignment, and installer-friendly features to support robust electrical protection in demanding environments.
Product Information
Extended Description
1SDA067863R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP M DIP I R 25 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
4190b613-9f2a-4093-a383-751bb2a01557 China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3025JFF000XXX
E-Number (Norway)
4379434
EAN
8015644017590
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.12 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644017590
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.8 W
Rated Current (In)
25 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
Ekip M Dip I
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SDC210100D0206 | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature 1: 3P, 25 A, 690 V AC rated current and voltage. Business Impact: Protects essential loads while preserving system availability; Application: main distribution and machine protection in LV panels. Feature 2: High short-circuit capacity up to 100 kA (Ics/Icu varies by voltage). Business Impact: Fast, decisive fault clearance reduces equipment damage and downtime; Application: critical power feeds and transformer protection in industrial plants. Feature 3: Ekip M Dip I release with front-terminal access. Business Impact: Safer, faster trips and simplified wiring during installation and service; Application: maintenance-friendly protection in compact switchboards. Feature 4: Front bolt terminals with 6 N·m tightening torque. Business Impact: Reliable connections that resist loosening under vibration; Application: panel assemblies subjected to repetitive cycling. Feature 5: Busbar connection range 32.5–100 mm². Business Impact: Flexible wiring and retrofit capability without rewiring; Application: adaptable to varied panel layouts and upgrades. Feature 6: Compliance and eco-labels including IEC 60947-2 and RoHS/REACH declarations. Business Impact: Simplified procurement with traceable regulatory compliance; Application: global projects and green initiatives in manufacturing. Feature 7: 0.8 W power loss per pole. Business Impact: Lower energy waste and cooler operation; Application: energy-conscious installations with continuous duty requirements. Feature 8: Mechanical durability up to 25 000 cycles sintered for reliability. Business Impact: Longer service life and reduced maintenance cycles; Application: heavy-use protection in dynamic production lines. Feature 9: 690 V rated operational voltage with 8 kV impulse withstand. Business Impact: High-voltage safety margin and resilience against surges; Application: distribution boards serving high-demand equipment. Feature 10: Product family compatibility with SACE Tmax XT XT2 lines and Ekip M Dip I releases. Business Impact: Streamlined spare parts and uniform training; Application: large-scale rollout across facilities using ABB protection solutions.
Get a Quick Quote for a ABB 1SDA067863R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067863R1?
Enquire Now
FAQs
Install with the bolt-type front terminals, tighten to 6 N·m, and ensure the busbar cross-section is 32.5–100 mm². Use the recommended Main Circuit M6 screwdriver, orient the unit for easy access, and follow the XT2 wiring diagram to avoid mis-wiring during routine maintenance and testing.
Rated service short-circuit breaking capacity (Ics) is up to 100 kA at the applicable voltage, with a corresponding Icu (ultimate) rating also listed for typical 230–240 V operation. This ensures rapid fault clearance to protect downstream equipment and reduce damage potential.
Yes. The device is rated for 690 V AC operation, with 3P configuration, front-terminal interfaces, and a design aligned with IEC 60947-2 to safeguard high-energy LV systems in industrial environments.
The product provides a CE Declaration of Conformity and IEC 60947-2 compliance. UL and VDE certifications are not required for this model, aligning with ABB’s EcoSolutions and RoHS/REACH declarations for safe, compliant operation.
Schedule periodic torque checks on terminal connections (6 N·m), verify Ekip M Dip I release responsiveness, and document any firmware or wiring changes. Utilizing front-terminal access reduces maintenance time and downtime, delivering lower lifecycle costs and faster return on investment.