ABB 1SDA067864R1 Moulded Case Circuit Breaker - XT2H 63A, 690 V
Part Number: 1SDA067864R1
Quick Summary
ABB 1SDA067864R1 Moulded Case Circuit Breaker is a compact protection device for distribution panels and machine controls. Engineered for reliable fault interruption, it minimizes unplanned downtime by delivering precise tripping under overload and short-circuit conditions. This XT2H 3P unit complies with IEC 60947-2 and CE declarations, with LR and GL approvals supporting safe installation in global facilities. By combining front-terminal accessibility, robust 63 A nominal current, and a 690 V rating with high 100 kA breaking capacity, it reduces wiring effort and total cost of ownership. ABB EcoSolutions features and disassembly guidance help your team meet recycling targets and lower environmental impact while preserving performance in critical protection schemes.
Product Information
Extended Description
1SDA067864R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP M DIP I R 63 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
d3b664dc-ba57-46cb-abf1-48476a95421b China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3063JFF000XXX
E-Number (Norway)
4379435
EAN
8015644017606
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.12 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644017606
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.7 W
Rated Current (In)
63 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
Ekip M Dip I
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SDC210100D0206 | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal, fixed three-pole design with Ekip M Dip I release. Benefit: Simplifies wiring, reduces assembly time, and enhances field reliability in demanding industrial environments. Application: Ideal for distribution panels and machine control cabinets where fast, dependable protection is required. Feature: 63 A rated current and 690 V operating voltage with 100 kA Ics/Icu. Benefit: Improves protection for motors and transformers against short circuits, lowering risk and downtime. Application: Power distribution and motor control centers in manufacturing facilities. Feature: Front bolt terminals and 6 N·m tightening torque with a busbar range of 32.5–100 mm². Benefit: Consistent connections, reduces torque variance, and supports rapid commissioning during panel buildouts. Application: OEM assembly lines and retrofit projects. Feature: IEC 60947-2 compliance, RoHS/REACH declarations, and EPD with 55.70% recyclability. Benefit: Ensures regulatory alignment, facilitates sustainability reporting, and lowers total cost of ownership over the lifecycle. Application: Global manufacturing sites pursuing eco-friendly compliance. Feature: Compact dimensions (90 mm W × 130 mm H × 82.5 mm D) and 1.12 kg weight. Benefit: Easier handling, storage, and installation in tight switchgear spaces. Application: Lightweight protection modules in compact enclosures.
Get a Quick Quote for a ABB 1SDA067864R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067864R1?
Enquire Now
FAQs
Plan for front-terminal mounting with bolt connections and a tightening torque of 6 N·m. Use busbars between 32.5 and 100 mm² and ensure space for 90 mm width, 130 mm height, and 82.5 mm depth. The recommended main circuit screwdriver is M6, and align installation with IEC 60947-2 guidelines to ensure reliable operation and service life.
Yes. It is rated for 690 V operating voltage and provides high short-circuit protection with a service-breaking capacity up to 100 kA (Ics/Icu) across common industrial supply voltages. It is a 3P device with a 63 A nominal current, suitable for medium-scale power distribution and motor protection.
The XT2H model complies with IEC 60947-2 and CE declarations. It carries LR and GL approvals for broader industrial acceptance and traceability. Additional compliance considerations include RoHS/REACH declarations, EPD information, and WEEE-related environmental packaging data for responsible disposal.
Yes. The device features front-terminal connections with bolt terminals designed for busbars in the 32.5–100 mm² range. Tighten to 6 N·m to ensure solid contact. Front terminals simplify wiring in tight switchgear and support rapid replacement during maintenance without removing the device from the panel.
The XT2H delivers high reliability with a 100 kA Ics/Icu rating, reducing failure-driven downtime. The solid-state release provides precise tripping, lowering nuisance trips. Its modular design and front-terminal wiring speed up installation and replacement, improving labor efficiency. Environmental considerations from EPD and recyclability support long-term sustainability and potential regulatory advantages.