ABB 1SDA067865R1 Moulded Case Breaker - IEC60947-2
Part Number: 1SDA067865R1
Quick Summary
ABB Tmax XT2H 160A molded case breaker is designed for reliable three‑phase protection in industrial power panels. Engineers often struggle with space constraints and front-terminal wiring, making installation and maintenance time‑consuming. This unit supports IEC 60947-2 compliance and CE conformity, with RoHS and REACH declarations and an environmental profile that includes EPD and EN45555 recyclability data. By aligning with the SACE Tmax XT family, it delivers consistent performance, predictable protection, and safer, faster commissioning. This combination of compact footprint, clear wiring, and documented environmental credentials adds tangible business value by reducing downtime and facilitating compliant panel builds.
Product Information
Extended Description
1SDA067865R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP M DIP I R 100 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
b1180032-511c-4db2-908a-2efa12932a5d China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3100JFF000XXX
E-Number (Norway)
4379436
EAN
8015644017613
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.12 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644017613
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.2 W
Rated Current (In)
100 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
Ekip M Dip I
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SDC210100D0206 | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front terminals and three-pole fixed construction with a bolted terminal design. Business Impact: Simplifies wiring, speeds installation, and reduces risk of loose connections in harsh environments. Application: Ideal for main distribution panels and machine feeders where front-termination access is required and space is at a premium. Feature: Ekip M Dip I release with solid-state control options. Business Impact: Delivers precise, reliable tripping with fast response and configurable release for broader protection schemes. Application: Transformer and MCC protection where selective tripping improves system availability. Feature: High short‑circuit breaking capacity (Ics up to 100 kA per voltage level). Business Impact: Provides robust protection against transformer faults and heavy motor inrush, lowering risk of equipment damage. Application: Power distribution cabinets in manufacturing and process environments. Feature: Rated current 100 A and rated operating voltage 690 V. Business Impact: Supports mid‑sized distributions with a strong safety margin for routine load growth. Application: Controls and feeders across industrial plants requiring reliable, code‑compliant breakers. Feature: Compliance and environmental data (IEC60947‑2, CE DoC, RoHS/REACH, EPD). Business Impact: Ensures regulatory alignment, easier supplier QA, and sustainable disposal with documented recyclability. Application: Procurement and compliance workflows in modern factories. Feature: Durability and lifecycle performance (Electrical durability 8000 cycles, Mechanical durability 25000 cycles). Business Impact: Reduces maintenance intervals and total cost of ownership in high‑cycle environments. Application: Frequent switching in packaging, material handling, and process lines.
Get a Quick Quote for a ABB 1SDA067865R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067865R1?
Enquire Now
FAQs
XT2H front-terminal breakers are designed for bolt connections with a front access layout, supporting busbars from 32.5 to 100 mm². Tightening torque is 6 N·m, and the unit weighs about 1.12 kg with compact dimensions of 90 x 130 x 82.5 mm. This makes them well suited for space‑constrained MCCs and control cabinets while ensuring secure, vibration‑resistant wiring.
The device is a 3P molded case breaker rated for 100 A (I n), 690 V rated operational voltage, and 8 kV impulse withstand. It provides a service breaking capacity (I cs) up to 100 kA at common voltages and a short‑circuit breaking capacity (I cu) up to 100 kA across several voltages, making it suitable for robust industrial protection.
Yes. With a 3P XT2H configuration, 100 A rating, and a high I cs / I cu, it is well-suited for transformer protection within switchgear and distribution assemblies. The Ekip M Dip I release provides reliable coordination, while the front-terminal design simplifies front-access wiring in transformer feeder cabinets.
The unit includes IEC 60947-2 compliance, CE Declaration of Conformity, RoHS and REACH declarations, and an environmental profile (EPD). Additional documentation covers disassembly instructions, recyclability data per EN45555, and a CMRT conflict minerals template, supporting governance and sustainability requirements in regulated markets.
Electrical durability is rated at up to 8,000 cycles and mechanical durability up to 25,000 cycles, supporting high‑frequency switching in demanding lines. The front-terminal design reduces wiring faults, while documented torque specifications and compatible busbar ranges streamline periodic maintenance and reduce total cost of ownership.