ABB 1SDA067873R1 Moulded Case Circuit Breaker - IEC 60947-2

Part Number: 1SDA067873R1
Manufacturer
ABB
Part number
1SDA067873R1

Quick Summary

Moulded Case Circuit Breaker from ABB provides reliable protection for three-phase power distribution in industrial facilities. Engineers often face nuisance trips and challenging wiring in control panels, and this XT2H solution minimizes those issues with a precise 25 A rating and convenient front-terminal design. It complies with IEC 60947-2 and carries CE conformity, plus third-party approvals such as GL and LR, reinforcing regional suitability and safety. In practice, this device supports faster installations, safer maintenance, and consistent protection while aligning with ABB EcoSolutions for sustainable end-of-life and recyclability benefits. For buyers seeking robust, standards-compliant protection with easy integration into SACE Tmax XT families, this MCCB delivers tangible business value.

Product Information

Extended Description

1SDA067873R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSIG R 25 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
53d31554-44ce-49b6-92c8-633eab8a6ce7 China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3025GFF000XXX
EAN
8015644017699
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644017699
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.80 W
Rated Current (In)
25 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V AC
Recommended Screw Driver
Main Circuit M6
Release
Ekip LSIG
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2 | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: 3-pole XT2 molded case breaker with 25 A rating and 690 V AC operating voltage. Business Impact: Provides compact, reliable power protection for distribution panels, reducing downtime and preventing equipment damage. Application: Ideal for three-phase industrial feeders in manufacturing lines and processing plants. Feature: Front-terminal connection and busbar compatibility (32.5 to 100 mm²). Business Impact: Simplifies wiring, speeds installation, and improves maintenance access. Application: Enclosures with limited rear clearance and needs quick replacements. Feature: Ekip LSIG release with fast opening time (30 ms with SOR/UVR options). Business Impact: Improves fault clearance speed, protecting motors and drives from damaging overloads. Application: Heavy-duty panel boards and motor control centers. Feature: High short-circuit capability (Ics up to 100 kA; Icu values across voltages). Business Impact: Supports safe operation in networks with transient faults and diverse voltages. Application: Data centers, process lines, and utility rooms requiring robust fault tolerance. Feature: Comprehensive compliance and environmental data (IEC 60947-2, CE, EPD, EN45555 recyclability). Business Impact: Eases regulatory adherence and sustainability reporting while reducing total cost of ownership. Application: Global deployments with emphasis on responsible design and recycling. Feature: Lightweight yet sturdy design (weight 1.2 kg; compact footprint 90 × 130 × 82.5 mm). Business Impact: Reduces shipping, integration footprint, and panel modernization costs. Application: Retrofit projects and new line builds where space is at a premium.

Get a Quick Quote for a ABB 1SDA067873R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067873R1? Enquire Now

FAQs

Install this 3P MCCB using the front terminals, ensuring busbar connections between 32.5 and 100 mm². Tighten to 6 N·m and align the unit within a 90 × 130 × 82.5 mm footprint. The 1.2 kg device simplifies handling, while the Ekip LSIG mechanism offers reliable tripping in a compact form factor suitable for distribution boards.
Rated current is 25 A with a rated operating voltage of 690 V AC and a rated impulse withstand voltage of 8 kV. It supports Ics up to 100 kA depending on voltage and offers a rated ultimate breaking capacity (Icu) across applicable voltages. U i is 1000 V AC, and the unit provides 3P protection with front-terminal connections.
Yes. With 3P protection, front-terminal access, 690 V rating, and Ekip LSIG release, it is well-suited for motor feeders and distribution panels. The compact XT2 framework enables easy integration into MCCB-based motor control centers, while the 30 ms opening time improves fault clearance for motors and drives.
The unit carries CE conformity with a DoC, GL and LR certificates, and is listed for environmental considerations such as EN45555 recyclability and EPDs for Tmax XT XT2/ELT. Note that UL and VDE certifications are listed as not required for this variant. WEEE and RoHS compliance are part of the specification package.
The MCCB reduces maintenance costs through high durability: electrical durability up to 8000 cycles and mechanical durability up to 25000 cycles, with a low power loss of 0.80 W per pole. Front-terminal wiring speeds installation, lowering labor costs, while robust fault protection minimizes downtime and extends panel life in high-demand environments.