ABB 1SDA067875R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067875R1
Quick Summary
ABB 1SDA067875R1 Moulded Case Circuit Breaker protects distribution panels in industrial automation applications. Operators often struggle with downtime due to improper protection settings or difficult field integration. This device adheres to IEC60947-2 and is CE marked, with additional LR and GL certifications for global deployment; it also aligns with RoHS and CMRT requirements for sustainable sourcing. By offering front-terminal, bolt-type connections and a 100 A rating, it simplifies installation and improves reliability. Leveraging Ekip LSIG release improves selective tripping and reduces nuisance trips, delivering safer, more efficient panel protection while supporting maintenance planning and compliance reporting. This combination helps engineers meet project schedules and budgets.
Product Information
Extended Description
1SDA067875R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSIG R 100 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
d5fd5c9f-1d7a-4d23-98cb-89022cb8cd79 China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3100GFF000XXX
EAN
8015644017712
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644017712
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.20 W
Rated Current (In)
100 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V AC
Recommended Screw Driver
Main Circuit M6
Release
Ekip LSIG
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2 | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Three-pole XT2H style molded case with front terminals and bolt connections. Business Impact: Ensures robust, tidy wiring and faster installation in control panels, reducing labour costs and error margins. Application: Suitable for switchgear, motor control centers, and distribution panels in manufacturing and process industries. Feature: Ekip LSIG solid-state release. Business Impact: Delivers precise, selective protection with improved coordination, minimizing unnecessary trips and downtime. Application: Critical loads such as conveyors and pumps in automated lines. Feature: 100 A rated current and 690 V AC rating with 100 kA short-circuit capability. Business Impact: Supports scalable protection for medium-load circuits while meeting fast fault-clearance requirements, lowering risk of equipment damage. Application: Data centers, packaging lines, and power distribution feeders. Feature: Front-terminal, bolt-type connection with 6 N·m tightening torque and busbar range 32.5–100 mm². Business Impact: Simplifies field wiring, ensures reliable contact, and accommodates common busbar layouts, easing retrofits. Application: Modernizing legacy panels or integrating with new panel build-outs. Feature: Compliance and sustainability package (RoHS, CMRT, EPD; End-of-Life disassembly guidance). Business Impact: Helps customers meet regulatory obligations and corporate ESG goals while enabling easier end-of-life planning. Application: Projects requiring traceability and responsible disposal.
Get a Quick Quote for a ABB 1SDA067875R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067875R1?
Enquire Now
FAQs
Yes. The device uses front terminal connections with bolt-type terminals designed for straightforward wiring and secure clamping. It supports busbars within the 32.5 to 100 mm² range and requires a 6 N·m tightening torque, enabling quick, repeatable installations across standard control panels and new builds alike.
The breaker is rated for 100 A, 690 V AC, with a rated short-circuit breaking capacity (Ics/Icu) up to 100 kA depending on voltage, and a rated service short-circuit capacity matching IEC 60947-2 requirements. Electrical durability is 120 cycles/hour with 8,000 cycles of mechanical endurance, supporting long service life in demanding environments.
Yes. Its 3P configuration, front-terminal mounting, and Ekip LSIG release provide selective protection and fast fault clearance, which are crucial for data centers and manufacturing lines. The 100 A rating and 690 V capability suit feeders, motor control centers, and critical loads while maintaining coordination with upstream protection devices.
The unit aligns with IEC 60947-2 and carries CE certification. Additional recognition includes LR and GL certifications for global deployment, RoHS compliance, CMRT for conflict minerals reporting, and EPDs for environmental impact disclosures, supporting corporate sustainability and regulatory audit readiness.
Engineered for long life, the XT2 LSIG release provides reliable tripping performance with reduced nuisance trips, lowering maintenance and downtime costs. Front-terminal wiring, standardized torque, and compatible dimensions simplify future upgrades and spares management, contributing to lower total cost of ownership for panel protection in evolving automation projects.