ABB 1SDA067886R1 Automatic Circuit Breaker - IEC60947-2
Part Number: 1SDA067886R1
Quick Summary
ABB 1SDA067886R1 Automatic Circuit Breaker is a three-phase protection device designed to safeguard motor circuits and distribution panels. This compact, front-terminal unit reduces wiring complexity and speeds up commissioning, addressing common integration challenges in new builds or upgrades. The XT2 family within SACE Tmax XT offers robust performance aligned with IEC60947-2, CE conformity, and RoHS/REACH compliance, ensuring regulatory-ready installations. In addition to reliability, this device delivers predictable trip behavior and easy serviceability, supporting maintenance planning and uptime. For engineers and procurement teams, the combination of 20 A rated current, 690 V capability, and front-terminal accessibility translates into lower total cost of ownership and smoother project execution when upgrading legacy systems or expanding control cabinets.
Product Information
Extended Description
1SDA067886R1 ABB: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-M-I R 20 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE3020KFF000XXX
E-Number (Norway)
4379443
EAN
8015644017828
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.12 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
131 mm
Package Level 1 Height
212 mm
Package Level 1 Depth / Length
147 mm
Package Level 1 Gross Weight
1.22 kg
Package Level 1 EAN
8015644017828
Circuit Breaker Type to be Associated
Motor Protection
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 3p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.8 W
Rated Current (In)
20 A
Rated Frequency (f)
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
Ekip M-I
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2 | Release Ekip G-LS/I, Ekip N-LS/I, Ekip M-LIU, Ekip M-I XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature: Front-terminal, fixed three-pole design enables quick, secure wiring and reduces installation time. Business Impact: Improves reliability during panel assembly and speeds up commissioning. Application: Motor protection and distribution boards in industrial cabinets minimize field wiring errors. Feature: Ekip M-I release provides precise, reliable protection with fast trip performance. Business Impact: Reduces nuisance trips and protects critical loads, lowering unplanned downtime. Application: Transformer feeders and high-inertia loads where accurate protection is essential. Feature: Busbar connection supporting 32.5 to 100 mm² cross-sections offers flexible integration. Business Impact: Adapts to a wide range of panel builders and reduces rework. Application: Main circuit installations in mid-size switchboards and control panels. Feature: Rated current of 20 A and rated operational voltage of 690 V AC suit standard low-voltage distribution. Business Impact: Aligns with common industrial utilities, enabling standardized protection across multiple circuits. Application: Light to medium motor loads and feeder circuits in manufacturing lines. Feature: Tightening torque of 6 N·m ensures consistent, repeatable installation. Business Impact: Minimizes torque variation and electrical contact resistance over time. Application: Field terminations and factory assembly lines where reliability matters. Feature: Electrical durability of 8000 cycles and mechanical durability of 25000 cycles extend service life. Business Impact: Lower maintenance costs and longer intervals between parts replacement. Application: Repeated switching in production environments and aging infrastructure refreshes. Feature: Compact footprint (90 mm width x 130 mm height x 82.5 mm depth) and weight of 1.12 kg. Business Impact: Simplifies equipment layout and reduces enclosure space requirements. Application: Dense control panels and retrofit projects where space is at a premium. Feature: IEC60947-2 standard compliance and CE Declaration of Conformity provide regulatory assurance. Business Impact: Eases procurement audits and speeds approval processes. Application: Global installations requiring standardized low-voltage protection. In practice, these attributes combine to deliver a dependable protection solution with installation efficiency, adaptability, and long-term cost savings for industrial users.
Get a Quick Quote for a ABB 1SDA067886R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067886R1?
Enquire Now
FAQs
For optimal performance, ensure busbar connections are within 32.5 to 100 mm², secure front-terminal bolts with a tightening torque of 6 N·m, and verify the unit is mounted in accordance with IEC60947-2 requirements. This approach reduces contact resistance and promotes consistent tripping behavior in 20 A circuits up to 690 V.
The Ekip M-I release provides precise, AC-operating trip characteristics, improving selectivity and reducing the risk of nuisance trips under transient faults. This translates to shorter unplanned outages and better protection for motors and transformers in production lines.
Yes. With fixed front-terminal design and a compact 90 mm wide footprint, the XT2H 160 fits common low-voltage panel configurations and can be wired from the front, accelerating installation and simplifying future maintenance in retrofit projects.
The device complies with IEC60947-2 and carries a CE Declaration of Conformity. It is RoHS and REACH compliant, and environmental declarations (EPD) are available for Tmax XT XT2 ELT families, supporting regulatory and sustainability requirements in globally deployed facilities.
With an 8000 electrical cycles and 25000 mechanical cycles rating, the XT2H 160 reduces replacement frequency in high-switching applications. Its front-terminal design minimizes installation time, and standardized components streamline spare parts inventories, delivering lower lifecycle costs and predictable maintenance planning.