ABB 1SDA067904R1 Moulded Case Circuit Breaker is a 4-pole protection device designed for 690 V AC power distribution in industrial panels. Engineers often struggle with reliable tripping, front-terminal access, and lifecycle data when selecting switchgear. This device aligns with IEC 60947-2 standards and CE conformity, and ABB EcoSolutions guidance offers recyclable packaging and end-of-life instructions. The combination of robust protection, easy installation, and lifecycle transparency supports safer, more cost-effective panel builds while meeting regulatory and sustainability goals.

Product Information

Extended Description

1SDA067904R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSI R 63 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
8bea7586-46f9-46a7-b831-e88dd4fd5c34 China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4063FFF000XXX
E-Number (Norway)
4379705
EAN
8015644018009
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.6 kg
Package Level 1 EAN
8015644018009
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.70 W
Rated Current (In)
63 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V AC
Recommended Screw Driver
Main Circuit M6
Release
Ekip LSI
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2 | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: Ekip LSI release provides selective tripping and fast opening, reducing fault propagation and downtime in critical feeders; ideal for transformer and generator protection in heavy industry. Application: main distribution panels and motor feeders. Feature → Business Impact → Application: Front-terminal bolt connections with 6 N·m tightening torque enable reliable field assembly and reduce maintenance calls; suitable for panel builders and retrofit projects. Application: compact switchgear in tight control rooms. Feature → Business Impact → Application: Rated voltage of 690 V AC and 1000 V insulating capability allows safe operation across diverse industrial networks; improves system tolerance to transients and supports long cable runs. Application: multi-voltage distributions and external grid interfaces. Feature → Business Impact → Application: Ics up to 100 kA at lower voltages (220–240 V) and substantial Icu ratings deliver high fault tolerance; minimizes equipment damage and downtime. Application: critical power corridors and distribution transformers. Feature → Business Impact → Application: Power loss of 1.70 W per pole reduces heat generation and energy consumption in panels; supports energy efficiency targets. Application: high-density switchboards and low-heat assemblies. Feature → Business Impact → Application: Compact dimensions (120 mm W x 130 mm H x 82.5 mm D) and 1.6 kg weight simplify panel layout and logistics; improves installation speed. Application: OEMs and panel shops needing space-efficient protection. Feature → Business Impact → Application: Compliance with RoHS, REACH, CMRT, and EPD disclosures; eases regulatory audits and customer sustainability reporting. Application: industries with strict material compliance and green procurement.

Get a Quick Quote for a ABB 1SDA067904R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067904R1? Enquire Now

FAQs

Installation requires securing the device on a 4-pole mounting frame, connecting busbar conductors in the range 32.5 to 100 mm², and tightening all front terminals to 6 N·m. Use a Main Circuit M6 screwdriver and ensure adequate clearance for hinged access and future maintenance. The unit weighs 1.6 kg and fits 120 mm wide panels for space-efficient layouts.
This XT2 4P breaker provides a Rated Service Short-Circuit Breaking Capacity of up to 100 kA at 220–240 V, and 70 kA at higher voltages such as 380–440 V. It also offers a high Icu rating across multiple voltage levels, ensuring robust protection against fault currents while maintaining selectivity within protected circuits.
Yes. It delivers a Rated Operational Voltage of 690 V AC and an insulation voltage of 1000 V AC, with an 8 kV rated impulse withstand. Combined with Ekip LSI release and front-terminal access, it is well-suited for central distribution cabinets, transformers, and heavy-duty motor circuits in industrial environments.
The product adheres to IEC 60947-2 standards and CE conformity, with supporting environmental data such as RoHS and REACH declarations, an Environmental Product Declaration (EPD) for Tmax XT XT2 ELT, and recycling guidance per EN45555. ABB also provides end-of-life disassembly instructions to facilitate responsible disposal.
Lifecycle benefits include the availability of End Of Life disassembly instructions, packaging disposal guidance, and a recyclability rate of 55.70% per EN45555. The unit supports predictable maintenance with quick-front terminal access, low power loss (1.70 W per pole), and documented longevity in both electrical (up to 8000 cycles) and mechanical (up to 25,000 cycles) tests.