ABB 1SDA067909R1 Moulded Case Circuit Breaker - IEC60947-2

Part Number: 1SDA067909R1
Manufacturer
ABB
Part number
1SDA067909R1

Quick Summary

ABB 1SDA067909R1 MCCB is a Tmax XT molded case circuit breaker for industrial power distribution. Engineers face challenges with panel space, uptime, and regulatory compliance in modern switchgear. It complies with IEC 60947-2 and carries a CE Declaration of Conformity, with environmental declarations (EPD) and RoHS compliance supporting sustainable design. This compact 4-pole unit with front terminals delivers reliable protection, easy front-access wiring, and compatibility with Tmax XT family accessories. By combining a compact form factor, robust electrical durability, and clear technical documentation, it reduces installation time, lowers total cost of ownership, and simplifies maintenance workflows for electrical designers and procurement teams.

Product Information

Extended Description

1SDA067909R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSI R 25 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
22345eec-6697-4163-b3ab-9c2a10af0d3a China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4025GFF000XXX
EAN
8015644018054
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.6 kg
Package Level 1 EAN
8015644018054
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 0.80 W
Rated Current (In)
25 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V AC
Recommended Screw Driver
Main Circuit M6
Release
Ekip LSIG
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2 | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Front-terminal 4-pole XT2 construction with LSIG release enables fast wiring and reliable fault control. This directly reduces installation time and wiring errors, supporting higher panel density and safer maintenance in demanding environments. It is ideal for power distribution boards in manufacturing lines requiring accessible wiring and dependable interrupting performance. The rated 690 V AC and 25 A nominal current, with a high short-circuit capacity, provides strong protection across standard industrial voltages, protecting motors and feeders from faults in machine centers and tooling lines. The 230/240 V Ics of up to 100 kA and 690 V Ics of 15 kA ensure quick fault clearance without unnecessary downtime. Front bolt terminals with 6 N·m tightening torque and a busbar connection range of 32.5 to 100 mm² deliver secure terminations, reducing maintenance fallout and improving reliability during routine inspections. Compliance and sustainability features including IEC60947-2, CE, RoHS/REACH, and EPD support safer procurement and lower lifecycle risk, while recyclability data helps meet corporate ESG targets. The compact footprint (120 × 130 × 82.5 mm) and a mass of 1.6 kg make retrofits and space-constrained installations feasible without sacrificing performance. This combination suits panel builders, OEMs, and upgrade projects where safety, compliance, and efficiency matter.

Get a Quick Quote for a ABB 1SDA067909R1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in ABB 1SDA067909R1? Enquire Now

FAQs

Choose front-terminal mounting for accessible wiring and use the 4P configuration to maximize panel density. Ensure busbar connection within 32.5 to 100 mm² and tighten terminals to 6 N·m. The device dimensions (120 × 130 × 82.5 mm) and weight (1.6 kg) support compact layouts and straightforward serviceability.
Rated current is 25 A with a rated voltage of 690 V AC. Short-circuit capability is up to 100 kA at 230/240 V and 15 kA at 690 V, providing robust protection for feeders and motors. It carries 4P operation with front terminals and LSIG release for reliable fault interruption.
Yes. The 4P configuration supports multi-phase protection for feeders and machines. Its front-terminal design and 6 N·m tightening torque simplify wiring in control cabinets, while the XT2 release provides reliable tripping performance. It’s compatible with Tmax XT accessories, enabling quick integration with existing switchgear and control systems.
The device aligns with IEC60947-2 and carries a CE Declaration of Conformity. It also includes RoHS/REACH declarations and an Environmental Product Declaration (EPD) for Tmax XT XT2 ELT, along with recyclability data (55.70% EN45555). These certifications facilitate regulatory compliance and sustainable procurement.
The XT2 MCCB reduces downtime through reliable short-circuit interruption and durable mechanical performance. Front-terminal wiring speeds up installation and service tasks, lowering labor costs. Its documented lifecycle data and recyclability support ESG reporting, while standardized maintenance intervals help predict Total Cost of Ownership and optimize spare-part inventory.