ABB 1SDA067911R1 Moulded Case Circuit Breaker - IEC60947-2
Part Number: 1SDA067911R1
Quick Summary
ABB 1SDA067911R1 Moulded Case Circuit Breaker protects industrial power distribution panels from short circuits and overloads in automation and manufacturing environments. Engineers often confront wiring complexity and inconsistent protection across multi-pole feeders, which this device helps mitigate with a compact, front-terminal design. This solution aligns with IEC 60947-2 and CE conformity, with GL and LR certifications available for broader international compliance, reinforcing reliability in global projects. By leveraging SACE Tmax XT technology and a 4P configuration, the product delivers robust protection while enabling faster assembly, improved serviceability, and reduced lifecycle costs for panel builders and maintenance teams. In essence, it pairs industry-standard protection with practical installation advantages and long-term sustainability benefits.
Product Information
Extended Description
1SDA067911R1 ABB: C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSIG R 100 A
ABB EcoSolutions
Yes
ABB Site Meeting Group Waste To Landfill Target
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions
Disassembly instructions Tmax XT XT2 ELT
Environmental Product Declaration - EPD
EPD Tmax XT XT2 ELT (CN) | EPD Tmax XT XT2 ELT (IT)
Recyclability Rate of the Product acc. to EN45555
Design for Closing Resource Loops - Standard EN45555 - 55.70 %
REACH Declaration
REACh Declaration ABB Sace circuit breakers
RoHS Information
RoHS Declaration ABB Sace circuit breakers
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)
CMRT - Conflict Minerals Reporting Template
Toxic Substances Control Act - TSCA
Toxic Substances Control Act (TSCA) declaration
SCIP
d1011f04-c519-4192-bfbe-137c4c46646a China (CN)
Environmental Information
Breakers - Packaging disposal information
Order Code US and Canada
XT2HE4100GFF000XXX
EAN
8015644018078
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
130 mm
Package Level 1 Height
208 mm
Package Level 1 Depth / Length
145 mm
Package Level 1 Gross Weight
1.6 kg
Package Level 1 EAN
8015644018078
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
CAD Dimensional Drawing
XT2 4p FIXED F
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC
Electrical Durability
120 cycles per hour | 8000 cycle
Mechanical Durability
240 cycles per hour | 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 30 ms | CB with UVR 30 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.20 W
Rated Current (In)
100 A
Rated Frequency (f)
50/60 Hz
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V AC
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 100 kA | (230 V AC) 100 kA | (240 V AC) 100 kA | (380 V AC) 70 kA | (415 V AC) 70 kA | (440 V AC) 65 kA | (500 V AC) 50 kA | (525 V AC) 30 kA | (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V AC
Recommended Screw Driver
Main Circuit M6
Release
Ekip LSIG
Release Type
EL
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ATEX Certificate
No certification needed
Data Sheet, Technical Information
SACE Tmax XT IEC Low voltage molded case circuit-breakers Catalog | SACE Tmax XT IEC TECHNICAL CHARACTERISTICS Low voltage molded case circuit-breakers
Declaration of Conformity - CE
EC Declaration of Conformity Tmax XT2
GL Certificate
1SDL000163R0093
LR Certificate
LRs certificate Tmax XT
UL Certificate
No certification needed
VDE Certificate
No certification needed
Dimension Diagram
XT2 3p-4p fixed front terminals
Mechanical Drawings
XT2 3p-4p fixed front terminals
Wiring Diagram
Circuit diagram for XT1, XT2, XT3 and XT4
Instructions and Manuals
Installation Instructions XT2 | Ekip C Dip LSI, Ekip C Dip LSIG and LIG XT2-XT4
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Feature → Business Impact → Application: The 4-pole, front-terminal design reduces wiring complexity and shortens panel assembly time, enabling safer commissioning and easier field updates in 690 V AC distribution. This translates to lower labor costs and faster project timelines for industrial facilities using multi-feed switchboards. Feature → Business Impact → Application: Ekip LSIG solid-state release provides fast, precise tripping with consistent response, minimizing downtime during motor and transformer protection scenarios in high-demand production lines. This improves overall equipment effectiveness (OEE) and reduces fault-related outages in manufacturing environments. Feature → Business Impact → Application: Busbar connection for 32.5–100 mm² cables with 6 N·m tightening torque ensures secure, repeatable terminations, decreasing loose connections risk and maintenance visits in high-vibration panel enclosures. Ideal for centralized power distribution in process plants. Feature → Business Impact → Application: IEC 60947-2 compliant design, 690 V rated operational voltage and 100 A rated current give engineers a compliant, scalable protection device for international projects, supporting standardization across global sites while maintaining performance. Feature → Business Impact → Application: Front-terminal, bolt-type connections and compact dimensions enable easier retrofits and modular replacements in existing panels, reducing downtime during upgrades and enabling flexible modernization of aging electrical infrastructures. Feature → Business Impact → Application: Comprehensive environmental and compliance data, including RoHS/ReACH declarations and end-of-life disassembly guidance, supports sustainable design practices and responsible recycling programs, aligning with corporate ESG goals and regional regulatory requirements.
Get a Quick Quote for a ABB 1SDA067911R1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in ABB 1SDA067911R1?
Enquire Now
FAQs
This device uses front-terminal connections and supports busbar ranges from 32.5 to 100 mm², with a tightening torque of 6 N·m. Typical installation benefits include faster wiring, reduced panel depth, and improved accessibility for maintenance. The 120 mm width and 130 mm height, plus 82.5 mm depth, help determine space in compact control enclosures and ensure compatibility with standard MCCBs in mixed IT and power distribution layouts.
The Ekip LSIG solid-state release provides dependable, rapid tripping with a stated opening time of about 30 ms, improving fault isolation and minimizing collateral damage to downstream equipment. This is particularly beneficial for motor feeders and transformer protection in automation lines, where short-circuit events must be contained quickly to maintain process continuity.
Yes. Rated Operational Voltage is 690 V AC and Rated Current is 100 A, with a 4P configuration and front-terminal connections. It also offers substantial short-circuit breaking capacity across applicable voltage classes, which makes it suitable for medium-voltage protection tasks in industrial control panels that require robust, standards-compliant protection.
The product carries a CE declaration of conformity and adheres to IEC 60947-2 standards. Additional certifications include GL and LR certificates, and RoHS/REACH declarations. End-of-life and disassembly guidance are provided for sustainable recycling. This combination supports regulatory compliance across European and global sites and simplifies supplier qualification for panel projects.
With electrical durability rated at up to 8000 cycles and mechanical durability up to 25,000 cycles, this breaker offers long service life and reduced maintenance intervals. Its reliable LSIG release and front-terminal design minimize downtime during retrofits and routine inspections, delivering tangible ROI through extended intervals between replacements and faster commissioning in new builds.